R6 · Residential (R-6)
Newcastle, WA · NMC 18.08.030; 18.12.030 · Official code
By right: 1 unit, 2 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single detached | Home✓ ADU✓ | — | — | — | — |
| Duplex | — | Home✓ ADU— | — | — | — |
| Stacked flats | — | Home✓ ADU— | — | — | — |
| Courtyard apartments | — | Home✓ ADU— | — | — | — |
| Senior citizen, assisted | — | HomeH ADU— | HomeH ADU— | HomeH ADU— | — |
| Mobile home park | — | HomeH ADU— | HomeH ADU— | HomeH ADU— | — |
| Triplex | — | — | HomeH ADU— | — | — |
| Townhouse | — | — | HomeH ADU— | HomeH ADU— | — |
| Fourplex | — | — | — | HomeH ADU— | — |
| Fiveplex | — | — | — | HomeH ADU— | — |
| Sixplex | — | — | — | HomeH ADU— | — |
| Multifamily | — | — | — | HomeH ADU— | — |
| Cottage housing | — | — | — | Home✓ ADU— | — |
| Adult family home | — | — | — | — | Home✓ ADU— |
| Community residential facility-I | — | — | — | — | HomeH ADU— |
| Community residential facility-II | — | — | — | — | HomeH ADU— |
| Transitional housing | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set NMC 18.12.030A | 4 units NMC 18.06.060
for Fourplex (4+ units) 5 units NMC 18.06.060
for Fiveplex (4+ units) 6 units NMC 18.06.190
for Sixplex (4+ units) 16 units NMC 18.19.110A
for Cottage housing (4+ units) |
| Minimum units | Not set NMC 18.12.030A | 4 units NMC 18.06.060
for Fourplex (4+ units); Cottage housing (4+ units) 5 units NMC 18.06.060
for Fiveplex (4+ units) 6 units NMC 18.06.190
for Sixplex (4+ units) 7 units NMC 18.06.130
for Multifamily (4+ units) |
| Minimum lot size | 6,000 sq ft NMC 18.12.030A | |
| Minimum lot width | 50 ft NMC 18.12.030A | |
| Minimum frontage | 30 ft NMC 18.12.030A | |
| Minimum density | Development standards apply at the parent lot level in middle housing developments. The rows for base and maximum density apply to the creation of lots or parent lots and only apply within lots for multifamily housing and/or condominium developments with greater than four units on a lot or parent lot. NMC 18.12.020D | 6 × 0.8 units per acre NMC 18.12.030A
for Senior citizen, assisted (2, 3, 4+ units); Mobile home park (2, 3, 4+ units); Fiveplex (4+ units); Sixplex (4+ units); Multifamily (4+ units) Not set NMC 18.12.030A
for Adult family home (group living); Community residential facility-I (group living); Community residential facility-II (group living); Transitional housing (group living); Permanent supportive housing (group living) |
| Maximum density | Development standards apply at the parent lot level in middle housing developments. The rows for base and maximum density apply to the creation of lots or parent lots and only apply within lots for multifamily housing and/or condominium developments with greater than four units on a lot or parent lot. NMC 18.12.020D
for Single detached (1 unit); Duplex (2 units); Stacked flats (2 units); Courtyard apartments (2 units); Triplex (3 units); Townhouse (3, 4+ units); Fourplex (4+ units) 2 × 6 units per acre NMC 18.19.110C; 18.12.030A
for Cottage housing (4+ units) Not set NMC 18.12.030A
for Adult family home (group living); Community residential facility-I (group living); Community residential facility-II (group living); Transitional housing (group living); Permanent supportive housing (group living) | |
| Maximum residents | Not set NMC 18.06.030 | 6 persons NMC 18.06.010
for Adult family home (group living) 10 persons NMC 18.06.030
for Community residential facility-I (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft NMC 18.12.030A | |
| Side setback | 5 ft NMC 18.12.030A | |
| Total side setbacks | 15 ft NMC 18.12.030B.12 | 10 ft NMC 18.12.030B.12
for Duplex (2 units); Stacked flats (2 units); Courtyard apartments (2 units); Triplex (3 units); Townhouse (3, 4+ units); Fourplex (4+ units); Fiveplex (4+ units); Sixplex (4+ units) Not set NMC 18.19.130
for Cottage housing (4+ units) |
| Street side setback | 10 ft NMC 18.12.030B.12 | Not set NMC 18.19.130
for Cottage housing (4+ units) |
| Rear setback | 20 ft NMC 18.12.030A | 10 ft NMC 18.19.130B
for Cottage housing (4+ units) |
| Building separation | 5 ft NMC 18.12.030A | |
| Maximum height | 30 ft NMC 18.12.030A | |
| Maximum stories | Not set NMC 18.12.030A | 3 stories NMC 18.06.190
for Stacked flats (2 units) |
| Maximum lot coverage | 35% NMC 18.12.030A | 50% NMC 18.19.120A
for Cottage housing (4+ units) |
| Maximum impervious surface | 40% NMC 18.12.030A | |
| Minimum parking | 2 spaces per unit NMC 18.18.030F
for Single detached (1 unit); Mobile home park (2, 3, 4+ units) main dwelling units on the lot ÷ 3 spaces NMC 18.18.030F
for Senior citizen, assisted (2, 3, 4+ units)
for Multifamily (4+ units) Not set NMC 18.18.030F
for Adult family home (group living); Transitional housing (group living); Permanent supportive housing (group living) bedrooms in the whole project ÷ 2 spaces NMC 18.18.030F
for Community residential facility-I (group living); Community residential facility-II (group living) | |
| Maximum unit size | Not set NMC 18.12.030A | 1,700 sq ft NMC 18.19.120B
for Cottage housing (4+ units) |
| Minimum open space | Not set NMC 18.12.030A | the largest of 20, (400 × main dwelling units on the lot × 100) ÷ lot area% NMC 18.19.140A
for Cottage housing (4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units NMC 18.31.030; 18.08.030B.18 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft NMC 18.31.030H; 18.12.030A | |
| Side setback | 5 ft NMC 18.31.030H; 18.12.030A | |
| Rear setback | ||
| Maximum height | ||
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft NMC 18.31.030B | |
| Attached to the main house | Not required NMC 18.31.030C |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Subdivision, short NMC 20.03.020 | A | up to 9 NMC 20.01.020 |
Minimum density 6 × 0.8 units per acre NMC 18.12.030A |
Minimum lot size 6,000 sq ft NMC 18.12.030A; 18.12.100A Minimum lot width 50 ft NMC 18.12.030A Minimum frontage 30 ft NMC 18.12.030A |
| Subdivision NMC 20.04.020 | H | 10 or more NMC 18.06.190 |
Minimum density 6 × 0.8 units per acre NMC 18.12.030A |
Minimum lot size 6,000 sq ft NMC 18.12.030A; 18.12.100A Minimum lot width 50 ft NMC 18.12.030A Minimum frontage 30 ft NMC 18.12.030A |
| Unit lot subdivision NMC 20.09.020; 20.03.020Only for: Duplex, Stacked flats, Courtyard apartments, Triplex, Townhouse, Fourplex, Fiveplex, Sixplex, Cottage housing | A19 | — | Maximum units 9 units NMC 20.09.020 |
Minimum lot size No limit NMC 20.09.030B Minimum lot width No limit NMC 20.09.030B |
| Unit lot subdivision NMC 20.09.020; 20.04.020Only for: Duplex, Stacked flats, Courtyard apartments, Triplex, Townhouse, Fourplex, Fiveplex, Sixplex, Cottage housing | H20 | — | Maximum units No limit NMC 20.09.020 |
Minimum lot size No limit NMC 20.09.030B Minimum lot width No limit NMC 20.09.030B |
| Binding site plan NMC 20.05.020 | A21 | Maximum lots Not set NMC 20.05.010 |
— | Minimum lot size 6,000 sq ft NMC 18.12.030A; 18.12.100A Minimum lot width 50 ft NMC 18.12.030A Minimum frontage 30 ft NMC 18.12.030A |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The project uses residential density incentives to reach the maximum density
- The project uses residential density incentives to reach the maximum density
- The setback is along a property line abutting R-4 through R-6
- None of these is true:
- The setback is along a property line abutting R-4 through R-6
- ADUs on the lot is less than 1
- ADUs on the lot is at least 1
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is at most 6,000 sf
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is more than 6,000 sf
- Lot is within one-half mile walking distance of a major transit stop
- Bedrooms in one unit is at most 1
- Bedrooms in one unit is 2
- Bedrooms in one unit is at least 3
- The lot line abuts a public alley
- None of these is true:
- The lot line abuts a public alley
- The accessory dwelling unit is in a detached structure
- None of these is true:
- The accessory dwelling unit is in a detached structure
- Lot is within one-half mile of a major transit stop
- None of these is true:
- Lot is within one-half mile of a major transit stop
- Main dwelling units on the lot is at most 9
- All of these are true:
- Main dwelling units on the lot is more than 9
- The unit lot subdivision is combined with a planned unit development or development agreement
- A portion or all of the land will be subject to the procedures for condominiums in Chapter 64.32 or 64.34 RCW