Sign in

DT · Downtown Transition

Newcastle, WA · NMC 18.08.030; 18.12.040 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Senior citizen, assisted—
HomeH1 ADU—
HomeH1 ADU—
HomeH1 ADU—
—
Triplex——
Home✓1 ADU—
——
Townhouse——
Home✓2 ADU—
Home✓2 ADU—
—
Fourplex———
Home✓1 ADU—
—
Fiveplex———
Home✓1 ADU—
—
Sixplex———
Home✓1 ADU—
—
Multifamily———
Home✓1 ADU—
—
Cottage housing———
Home✓1 ADU—
—
Adult family home————
Home✓1 ADU—
Community residential facility-I————
HomeH1 ADU—
Community residential facility-II————
HomeH1 ADU—
Co-living housing————
Home✓2 ADU—
Dormitory————
HomeH3 ADU—
Indoor emergency shelters————
Home✓2 ADU—
Indoor emergency housing————
Home✓2 ADU—
Transitional housing————
Home✓2 ADU—
Permanent supportive housing————
Home✓2 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set NMC 18.12.040A
4 units NMC 18.06.060
for Fourplex (4+ units)1
5 units NMC 18.06.060
for Fiveplex (4+ units)1
6 units NMC 18.06.190
for Sixplex (4+ units)1
16 units NMC 18.19.110A
for Cottage housing (4+ units)1
Minimum units4 units NMC 18.06.060
5 units NMC 18.06.060
for Fiveplex (4+ units)1
6 units NMC 18.06.190
for Sixplex (4+ units)1
Not set NMC 18.12.040A
for Townhouse (4+ units)2; Senior citizen, assisted (4+ units)1
7 units NMC 18.06.130
for Multifamily (4+ units)1
Maximum densityNot set NMC 18.12.040A
Development standards apply at the parent lot level in middle housing developments. The rows for base and maximum density apply to the creation of lots or parent lots and only apply within lots for multifamily housing and/or condominium developments with greater than four units on a lot or parent lot. NMC 18.12.020D
for Senior citizen, assisted (2, 3 units)1; Triplex (3 units)1; Townhouse (3, 4+ units)2; Fourplex (4+ units)1
48 units per acre, a fraction of 0.5 or more rounds up NMC 18.12.040A; 18.12.040B.2; 18.12.070C
for Fiveplex (4+ units)1; Sixplex (4+ units)1; Multifamily (4+ units)1; Senior citizen, assisted (4+ units)1
2 × 48 units per acre NMC 18.19.110C; 18.12.040A
for Cottage housing (4+ units)1
Maximum residentsNot set NMC 18.06.030
6 persons NMC 18.06.010
for Adult family home (group living)1
10 persons NMC 18.06.030
for Community residential facility-I (group living)1
Maximum sleeping unitsNot set NMC 18.12.040A
4 × ((48 × lot area) ÷ 43,560, rounded) sleeping units NMC 18.12.040A; 18.12.040B.22
for Co-living housing (group living)2

3. Building standards

StandardValueExceptions
Front setbackFront yard setbacks are not required within the downtown transition (DT) and downtown core (DC) zones. NMC 18.12.040B.1
10 ft NMC 18.19.130A
for Cottage housing (4+ units)1
Maximum front setbackBuildings shall be placed no further from the front property line than is needed for required street frontage improvements such as sidewalks, plazas and required landscaping. NMC 18.12.040B.6
Side setback
  • 20 ft4 NMC 18.12.040A
  • 0 ft5 NMC 18.12.040B.7
5 ft NMC 18.19.130C
for Cottage housing (4+ units)1
Rear setback
  • 20 ft4 NMC 18.12.040A
  • 0 ft5 NMC 18.12.040B.7
10 ft NMC 18.19.130B
for Cottage housing (4+ units)1
Building separationNot set NMC 18.12.040A
5 ft NMC 18.19.130D
for Cottage housing (4+ units)1
Maximum height45 ft NMC 18.12.040A
Maximum stories4 stories NMC 18.12.040A
Maximum lot coverage85% NMC 18.12.040A
50% NMC 18.19.120A
for Cottage housing (4+ units)1
Maximum impervious surface90% NMC 18.12.040A
Maximum floor area ratio
  • 2.56 NMC 18.12.040A
  • 17 NMC 18.12.040B.10
  • 2.58 NMC 18.12.040A
Minimum parking
  • 0 spaces per unit9 NMC 18.18.035B.1
  • 1 space per unit10 NMC 18.18.035B.2
  • 2 spaces per unit11 NMC 18.18.035B.3
main dwelling units on the lot ÷ 3 spaces NMC 18.18.030F
for Senior citizen, assisted (2, 3, 4+ units)1
  • 1.2 + ((main dwelling units on the lot ÷ 10, rounded up) ÷ main dwelling units on the lot) spaces per unit12 NMC 18.15.150B
  • 1.6 + ((main dwelling units on the lot ÷ 10, rounded up) ÷ main dwelling units on the lot) spaces per unit13 NMC 18.15.150B
  • 2 + ((main dwelling units on the lot ÷ 10, rounded up) ÷ main dwelling units on the lot) spaces per unit14 NMC 18.15.150B
for Multifamily (4+ units)1
Not set NMC 18.18.030F
for Adult family home (group living)1; Indoor emergency shelters (group living)2; Indoor emergency housing (group living)2; Transitional housing (group living)2; Permanent supportive housing (group living)2
bedrooms in the whole project ÷ 2 spaces NMC 18.18.030F
for Community residential facility-I (group living)1; Community residential facility-II (group living)1; Dormitory (group living)3
  • 0 spaces per unit15 NMC 18.18.030F
  • 0.25 spaces per unit16 NMC 18.18.030F
for Co-living housing (group living)2
Maximum unit sizeNot set NMC 18.12.040A
1,700 sq ft NMC 18.19.120B
for Cottage housing (4+ units)1
Minimum open spaceNot set NMC 18.12.040A
the largest of 20, (400 × main dwelling units on the lot × 100) ÷ lot area% NMC 18.19.140A
for Cottage housing (4+ units)1

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision, short NMC 20.03.020 A up to 9 NMC 20.01.020 —
Minimum lot size
Not set NMC 18.12.040A
Subdivision NMC 20.04.020 H 10 or more NMC 18.06.190 —
Minimum lot size
Not set NMC 18.12.040A
Unit lot subdivision NMC 20.09.020; 20.03.020Only for: Triplex, Townhouse, Fourplex, Fiveplex, Sixplex, Cottage housing A17 —
Maximum units
9 units NMC 20.09.020
Minimum lot size
No limit NMC 20.09.030B
Minimum lot width
No limit NMC 20.09.030B
Unit lot subdivision NMC 20.09.020; 20.04.020Only for: Triplex, Townhouse, Fourplex, Fiveplex, Sixplex, Cottage housing H18 —
Maximum units
No limit NMC 20.09.020
Minimum lot size
No limit NMC 20.09.030B
Minimum lot width
No limit NMC 20.09.030B
Binding site plan NMC 20.05.020 A19
Maximum lots
Not set NMC 20.05.010
—
Minimum lot size
Not set NMC 18.12.040A

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The use meets the locational restrictions on uses described in NMC 18.15.090
    • Nonresidential uses occupy a majority of the building's ground floor frontage
  2. Nonresidential uses occupy a majority of the building's ground floor frontage
  3. All of these are true:
    • The use meets the locational restrictions on uses described in NMC 18.15.090
    • Nonresidential uses occupy a majority of the building's ground floor frontage
    • The use is an accessory to a school, college/university or church
  4. The property line adjoins a single-family residential zone
  5. None of these is true:
    • The property line adjoins a single-family residential zone
  6. All of these are true:
    • Lot is within the community business center (CBC) overlay zone
    • The project uses FAR incentives to go above a 1:1 FAR in the CBC overlay zone
  7. All of these are true:
    • Lot is within the community business center (CBC) overlay zone
    None of these is true:
    • The project uses FAR incentives to go above a 1:1 FAR in the CBC overlay zone
  8. None of these is true:
    • Lot is within the community business center (CBC) overlay zone
  9. Lot is within one-half mile walking distance of a major transit stop
  10. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  11. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  12. Bedrooms in one unit is at most 1
  13. Bedrooms in one unit is 2
  14. Bedrooms in one unit is at least 3
  15. Co-living housing is less than 0.5 mile of a major transit stop
  16. None of these is true:
    • Co-living housing is less than 0.5 mile of a major transit stop
  17. Main dwelling units on the lot is at most 9
  18. All of these are true:
    • Main dwelling units on the lot is more than 9
    • The unit lot subdivision is combined with a planned unit development or development agreement
  19. Any of these is true:
    • Land is divided for sale or lease of commercially or industrially zoned property
    • A portion or all of the land will be subject to the procedures for condominiums in Chapter 64.32 or 64.34 RCW