Sign in

DC · Downtown Core

Newcastle, WA · NMC 18.08.030; 18.12.040 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Senior citizen, assisted—
HomeH1 ADU—
HomeH1 ADU—
HomeH1 ADU—
—
Multifamily———
Home✓2 ADU—
—
Adult family home————
Home✓1 ADU—
Community residential facility-I————
HomeH1 ADU—
Community residential facility-II————
HomeH1 ADU—
Co-living housing————
Home✓3 ADU—
Indoor emergency shelters————
Home✓3 ADU—
Indoor emergency housing————
Home✓3 ADU—
Transitional housing————
Home✓3 ADU—
Permanent supportive housing————
Home✓3 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum units7 units NMC 18.06.130
Not set NMC 18.06.190
for Senior citizen, assisted (4+ units)1
Maximum densityNot set NMC 18.12.040A
Development standards apply at the parent lot level in middle housing developments. The rows for base and maximum density apply to the creation of lots or parent lots and only apply within lots for multifamily housing and/or condominium developments with greater than four units on a lot or parent lot. NMC 18.12.020D
for Senior citizen, assisted (2, 3 units)1
48 units per acre, a fraction of 0.5 or more rounds up NMC 18.12.040A; 18.12.040B.2; 18.12.070C
for Multifamily (4+ units)2; Senior citizen, assisted (4+ units)1
Maximum residentsNot set NMC 18.06.030
6 persons NMC 18.06.010
for Adult family home (group living)1
10 persons NMC 18.06.030
for Community residential facility-I (group living)1
Maximum sleeping unitsNot set NMC 18.12.040A
4 × ((48 × lot area) ÷ 43,560, rounded) sleeping units NMC 18.12.040A; 18.12.040B.22
for Co-living housing (group living)3

3. Building standards

StandardValueExceptions
Front setbackFront yard setbacks are not required within the downtown transition (DT) and downtown core (DC) zones. NMC 18.12.040B.1
Maximum front setbackBuildings shall be placed no further from the front property line than is needed for required street frontage improvements such as sidewalks, plazas and required landscaping. NMC 18.12.040B.6
Side setback
  • 20 ft4 NMC 18.12.040A
  • 0 ft5 NMC 18.12.040B.7
Rear setback
  • 20 ft4 NMC 18.12.040A
  • 0 ft5 NMC 18.12.040B.7
Maximum height55 ft NMC 18.12.040A
Maximum stories5 stories NMC 18.12.040A
Maximum lot coverage85% NMC 18.12.040A
Maximum impervious surface90% NMC 18.12.040A
Maximum floor area ratio
  • 2.56 NMC 18.12.040A
  • 17 NMC 18.12.040B.10
  • 2.58 NMC 18.12.040A
Minimum parkingNot set NMC 18.18.030F
main dwelling units on the lot ÷ 3 spaces NMC 18.18.030F
for Senior citizen, assisted (2, 3, 4+ units)1
  • 1.2 + ((main dwelling units on the lot ÷ 10, rounded up) ÷ main dwelling units on the lot) spaces per unit9 NMC 18.15.150B
  • 1.6 + ((main dwelling units on the lot ÷ 10, rounded up) ÷ main dwelling units on the lot) spaces per unit10 NMC 18.15.150B
  • 2 + ((main dwelling units on the lot ÷ 10, rounded up) ÷ main dwelling units on the lot) spaces per unit11 NMC 18.15.150B
for Multifamily (4+ units)2
bedrooms in the whole project ÷ 2 spaces NMC 18.18.030F
for Community residential facility-I (group living)1; Community residential facility-II (group living)1
  • 0 spaces per unit12 NMC 18.18.030F
  • 0.25 spaces per unit13 NMC 18.18.030F
for Co-living housing (group living)3

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision, short NMC 20.03.020 A up to 9 NMC 20.01.020 —
Minimum lot size
Not set NMC 18.12.040A
Subdivision NMC 20.04.020 H 10 or more NMC 18.06.190 —
Minimum lot size
Not set NMC 18.12.040A
Binding site plan NMC 20.05.020 A14
Maximum lots
Not set NMC 20.05.010
—
Minimum lot size
Not set NMC 18.12.040A

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The use meets the locational restrictions on uses described in NMC 18.15.090
    • Nonresidential uses occupy a majority of the building's ground floor frontage
  2. All of these are true:
    • The use meets the locational restrictions on uses described in NMC 18.15.090
    • The housing is part of a mixed use development
    • Nonresidential uses occupy a majority of the building's ground floor frontage
  3. Nonresidential uses occupy a majority of the building's ground floor frontage
  4. The property line adjoins a single-family residential zone
  5. None of these is true:
    • The property line adjoins a single-family residential zone
  6. All of these are true:
    • Lot is within the community business center (CBC) overlay zone
    • The project uses FAR incentives to go above a 1:1 FAR in the CBC overlay zone
  7. All of these are true:
    • Lot is within the community business center (CBC) overlay zone
    None of these is true:
    • The project uses FAR incentives to go above a 1:1 FAR in the CBC overlay zone
  8. None of these is true:
    • Lot is within the community business center (CBC) overlay zone
  9. Bedrooms in one unit is at most 1
  10. Bedrooms in one unit is 2
  11. Bedrooms in one unit is at least 3
  12. Co-living housing is less than 0.5 mile of a major transit stop
  13. None of these is true:
    • Co-living housing is less than 0.5 mile of a major transit stop
  14. Any of these is true:
    • Land is divided for sale or lease of commercially or industrially zoned property
    • A portion or all of the land will be subject to the procedures for condominiums in Chapter 64.32 or 64.34 RCW