R2 · R-2 – Single-family and two-family residential zone
Moxee, WA · MMC 16.25.100; Table 16.30.010; Table 16.35.160 · Official code
By right: 1 unit, 2 units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| SF: Detached home | Home✓ ADU— | — | — | — | — |
| SF: Factory-built home | Home✓ ADU— | — | — | — | — |
| SF: Manufactured home on individual lot | — | — | — | — | |
| SF: Cluster development: Zero lot line (SF dwellings) | — | — | — | — | |
| SF attached dwellings (townhouses) | — | — | — | — | |
| MF: Two-family/duplexes | — | Home✓ ADU— | — | — | — |
| MF: Triplex/fourplex | — | — | — | ||
| SF: Bungalow court | — | — | — | HomeA ADU— | — |
| Adult family home | — | — | — | — | Home✓ ADU— |
| Boarding house/rooming house | — | — | — | — | Home✓ ADU— |
| Congregate care facility/retirement center | — | — | — | — | Home✓ ADU— |
| Assisted care facility | — | — | — | — | HomeA ADU— |
| Group home | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 4 units MMC 16.10.060; MMC Table 16.35.160 note 5 | 12 units MMC 16.35.080(5)(d); 16.10.020
for SF: Bungalow court (4+ units) |
| Minimum units | Not set MMC Table 16.35.160 | 4 units MMC 16.35.080(5)(d); 16.10.020
for SF: Bungalow court (4+ units) |
| Minimum lot size | 6,000 sq ft MMC Table 16.35.160 | 5,000 sq ft MMC Table 16.35.160
for SF: Cluster development: Zero lot line (SF dwellings) (1 unit)2 4,000 sq ft MMC 16.35.080(4)(a)
for SF attached dwellings (townhouses) (1 unit)2 7,000 sq ft MMC Table 16.35.160
2,000 × main dwelling units on the lot sq ft MMC 16.35.080(5)(a)
for SF: Bungalow court (4+ units) |
| Minimum lot width | 50 ft MMC Table 16.35.160 | 40 ft MMC 16.35.080(4)(a)
for SF attached dwellings (townhouses) (1 unit)2 60 ft MMC Table 16.35.160
Not set MMC 16.35.080(5)
for SF: Bungalow court (4+ units) |
| Maximum density | Not set MMC Table 16.35.160; 16.35.050(2) | 7.26 units per acre, a fraction of 0.5 or more rounds up MMC Table 16.35.160; 16.35.050(2)
for SF: Detached home (1 unit); SF: Factory-built home (1 unit); SF: Manufactured home on individual lot (1 unit)1; SF: Bungalow court (4+ units) 8.71 units per acre, a fraction of 0.5 or more rounds up MMC Table 16.35.160; 16.35.050(2)
12 units per acre, a fraction of 0.5 or more rounds up MMC Table 16.35.160; 16.35.050(2)
|
| Minimum development size | Not set MMC Table 16.35.160 | 14,000 sq ft MMC 16.35.080(5)(a)
for SF: Bungalow court (4+ units) |
| Maximum residents | Not set MMC 16.10 | 6 persons MMC 16.10.010; 16.35.070(3)(d)
for Adult family home (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft MMC Table 16.35.160 | |
| Side setback | ||
| Total side setbacks | Not set MMC Table 16.35.160 | 15 ft MMC 16.35.080(3)(e)(i); MMC Table 16.35.160
for SF: Cluster development: Zero lot line (SF dwellings) (1 unit)2 8 ft MMC 16.35.080(4)(b); MMC Table 16.35.160 note 4
for SF attached dwellings (townhouses) (1 unit)2 |
| Rear setback | 15 ft MMC Table 16.35.160 | 10 ft MMC 16.35.080(3)(e)(ii)
for SF: Cluster development: Zero lot line (SF dwellings) (1 unit)2 |
| Maximum height | 35 ft MMC Table 16.35.160; 16.35.040(2)(a) | |
| Maximum impervious surface | 60% MMC Table 16.35.160 note 3; 16.35.030 | |
| Minimum parking | 2 spaces per unit MMC Table 16.50.060 | 1 space per unit MMC Table 16.50.060
for MF: Triplex/fourplex (3, 4+ units)3 Off-street parking requirements for uses not specifically listed in Table 16.50.060 shall be determined by the administrative official using Level 1 review based upon the requirement for similar uses. MMC 16.50.050(7)
for Adult family home (group living); Congregate care facility/retirement center (group living); Assisted care facility (group living); Group home (group living) 1 space per sleeping unit MMC Table 16.50.060 (rooming house/boarding house)
for Boarding house/rooming house (group living) |
| Maximum unit size | Not set MMC Table 16.35.160 | |
| Minimum open space | Not set MMC Table 16.35.160 | |
| Maximum units per building | Not set MMC Table 16.35.160 | 2 units MMC 16.35.080(4)(b)(ii)
for SF attached dwellings (townhouses) (1 unit)2 1 unit MMC 16.10.020
for SF: Bungalow court (4+ units) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short plat MMC 16.60.090(1)(b); 16.60.080(4) | A | Minimum lots Not set MMC 16.60.080 Maximum lots 9 lots MMC 16.60.080(1); 16.10.190 |
— | Minimum lot size Lot size, width, depth, shape and orientation shall conform to the zoning standards applicable to the area within which the property is located. MMC 16.60.550(2); 16.60.540 Minimum lot width Lot size, width, depth, shape and orientation shall conform to the zoning standards applicable to the area within which the property is located. MMC 16.60.550(2); 16.60.540 Minimum lot depth Lot size, width, depth, shape and orientation shall conform to the zoning standards applicable to the area within which the property is located. MMC 16.60.550(2); 16.60.540 Minimum frontage Every lot shall be provided with frontage on a public street or approved private lane, as provided in MMC 16.60.590, connecting to an existing public street. MMC 16.60.550(2)(c)(i) Maximum units per lot Not set MMC 16.60.550 |
| Subdivision MMC 16.60.150(2); 16.60.180 | H | Minimum lots 10 lots MMC 16.10.190; 16.60.140(1) Maximum lots Not set MMC 16.60.140 |
— | Minimum lot size Lot size, width, depth, shape and orientation shall conform to the zoning standards applicable to the area within which the property is located. MMC 16.60.550(2); 16.60.540 Minimum lot width Lot size, width, depth, shape and orientation shall conform to the zoning standards applicable to the area within which the property is located. MMC 16.60.550(2); 16.60.540 Minimum lot depth Lot size, width, depth, shape and orientation shall conform to the zoning standards applicable to the area within which the property is located. MMC 16.60.550(2); 16.60.540 Minimum frontage Every lot shall be provided with frontage on a public street or approved private lane, as provided in MMC 16.60.590, connecting to an existing public street. MMC 16.60.550(2)(c)(i) Maximum units per lot Not set MMC 16.60.550 |
| SF: Cluster development MMC Table 16.30.010; 16.35.080(2); 16.35.080(2)(f)Only for: SF: Cluster development: Zero lot line (SF dwellings), SF attached dwellings (townhouses) | A | 3 or more MMC 16.35.080(2)(b) | Overall density must not exceed the density of the underlying zoning district. MMC 16.35.080(2)(a) | Minimum lot size Required development and design standards for cluster development are established in the District Standards Table (MMC 16.35.160) by development type. MMC 16.35.080(2)(d) Minimum lot width Required development and design standards for cluster development are established in the District Standards Table (MMC 16.35.160) by development type. MMC 16.35.080(2)(d) Minimum lot depth Required development and design standards for cluster development are established in the District Standards Table (MMC 16.35.160) by development type. MMC 16.35.080(2)(d) Minimum frontage Every lot shall be provided with frontage on a public street or approved private lane, as provided in MMC 16.60.590, connecting to an existing public street. MMC 16.60.550(2)(c)(i) Maximum units per lot 1 unit MMC 16.35.080(3)(b) |
| Planned development – residential MMC Table 16.30.010; 16.60.400 | H | — |
Area taken out for roads and utilities 25% MMC 16.60.350(2) |
Minimum lot size All zoning and subdivision requirements may be modified in a planned development in the interest of the expressed purposes above, except: (1) Permitted uses; (2) Street setbacks on exterior streets (i.e., the perimeters of the planned development district) as specified in the applicable zone designation; (3) Surveying standards; and (4) Engineering design and construction standards of public improvements but not including street right-of-way width. MMC 16.60.320 Minimum lot width All zoning and subdivision requirements may be modified in a planned development in the interest of the expressed purposes above, except: (1) Permitted uses; (2) Street setbacks on exterior streets (i.e., the perimeters of the planned development district) as specified in the applicable zone designation; (3) Surveying standards; and (4) Engineering design and construction standards of public improvements but not including street right-of-way width. MMC 16.60.320 Minimum lot depth All zoning and subdivision requirements may be modified in a planned development in the interest of the expressed purposes above, except: (1) Permitted uses; (2) Street setbacks on exterior streets (i.e., the perimeters of the planned development district) as specified in the applicable zone designation; (3) Surveying standards; and (4) Engineering design and construction standards of public improvements but not including street right-of-way width. MMC 16.60.320 Minimum frontage All zoning and subdivision requirements may be modified in a planned development in the interest of the expressed purposes above, except: (1) Permitted uses; (2) Street setbacks on exterior streets (i.e., the perimeters of the planned development district) as specified in the applicable zone designation; (3) Surveying standards; and (4) Engineering design and construction standards of public improvements but not including street right-of-way width. MMC 16.60.320 Maximum units per lot All zoning and subdivision requirements may be modified in a planned development in the interest of the expressed purposes above, except: (1) Permitted uses; (2) Street setbacks on exterior streets (i.e., the perimeters of the planned development district) as specified in the applicable zone designation; (3) Surveying standards; and (4) Engineering design and construction standards of public improvements but not including street right-of-way width. MMC 16.60.320 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The manufactured home is new and previously untitled and bears the Washington State or HUD insignia
- The cluster development has three or more lots
- Any of these is true:
- The project is a senior housing development (dwelling units for persons 62 years of age or older)
- The project is an affordable housing development
- Lot width is less than 56 ft
- All of these are true:
- Lot width is at least 56 ft
- Lot width is less than 66 ft
- All of these are true:
- Lot width is at least 66 ft
- Lot width is less than 76 ft
- All of these are true:
- Lot width is at least 76 ft
- Lot width is less than 86 ft
- Lot width is at least 86 ft
- Roof slope of the bungalow court cottages: at least 6:12, or at least 4:12 but less than 6:12 is six_twelve_or_steeper
- Roof slope of the bungalow court cottages: at least 6:12, or at least 4:12 but less than 6:12 is four_twelve_to_six_twelve
- Bedrooms in one unit is at most 1
- Bedrooms in one unit is at least 2
- Building stories is at most 1
- Building stories is more than 1
- Lot area is more than 21,780 sf
- Lot area is at most 21,780 sf
- None of these is true:
- The planned development makes large scale common area improvements and takes the full 20 percent density bonus