R-3 · R-3 Multifamily Residential District
Mount Vernon, WA · MVMC 17.24 · Official code
By right: 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, Two-Family or Duplex | — | Home✓ ADU— | — | — | — |
| Townhouse | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Dwelling, Multifamily | — | — | — | ||
| Permanent supportive housing facility | — | — | — | — | |
| Specialized housing for the elderly | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set MVMC 17.24.020 | 75 units MVMC 17.24.020(B)
for Dwelling, Multifamily (4+ units)1 35 units MVMC 17.73.050(C)(4)
for Dwelling, Multifamily (4+ units)2 80 units MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)3 |
| Minimum units | Not set MVMC 17.24.020 | 76 units MVMC 17.24.040(D)
for Dwelling, Multifamily (4+ units)1 36 units MVMC 17.73.050(C)(4)
for Dwelling, Multifamily (4+ units)2 |
| Minimum lot size | Not set MVMC 17.24.050 | 6,500 sq ft MVMC 17.24.050(A)(1)
for Dwelling, Two-Family or Duplex (2 units); Townhouse (2 units) |
| Minimum lot width | 60 ft MVMC 17.24.050(B) | Not set MVMC 17.24.050
for Dwelling, Two-Family or Duplex (2 units); Townhouse (2 units); Permanent supportive housing facility (4+ units)3 |
| Minimum lot depth | 80 ft MVMC 17.24.050(B) | Not set MVMC 17.24.050
for Dwelling, Two-Family or Duplex (2 units); Townhouse (2 units); Permanent supportive housing facility (4+ units)3 |
| Minimum frontage | 30 ft MVMC 17.24.050(B) | Not set MVMC 17.24.050
for Dwelling, Two-Family or Duplex (2 units); Townhouse (2 units); Permanent supportive housing facility (4+ units)3 |
| Minimum density | 10 units per acre MVMC 17.24.010 | No limit MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)3 |
| Maximum density | for Dwelling, Multifamily (3, 4+ units)1 30 units per acre, on the net lot area MVMC 17.73.050(A)
for Dwelling, Multifamily (3, 4+ units)2 No limit MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)3 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 10 ft MVMC 17.24.060(B) | |
| Street side setback | ||
| Rear setback | 20 ft MVMC 17.24.060(C) | |
| Building separation | 10 ft MVMC 17.24.090 | Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)3 |
| Maximum height | 50 ft MVMC 17.67.030(F)(4)
for Permanent supportive housing facility (4+ units)3 | |
| Maximum stories | 4 stories MVMC 17.67.030(F)(4)
for Permanent supportive housing facility (4+ units)3 | |
| Maximum lot coverage | 40% MVMC 17.24.070 | Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)3 |
| Minimum parking | for Dwelling, Two-Family or Duplex (2 units); Townhouse (2 units) The number of parking spaces required to serve a PSH facility shall reflect the proposed uses for such a facility. The applicant will be required to submit a parking study documenting the number of parking spaces needed to provide parking on a site. MVMC 17.67.030(G)
for Permanent supportive housing facility (4+ units)3 | |
| Minimum open space | Not set MVMC 17.24.060 | no less than 50 percent of the sum of the building footprints shall be in open space, landscaping, and active play or activity areas MVMC 17.24.040(D)
for Dwelling, Multifamily (4+ units)1 15% MVMC 17.67.030(I)
for Permanent supportive housing facility (4+ units)3 |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision MVMC 16.32.020(A) | A | up to 9 MVMC 16.04.010(D) | Minimum lot size Not set MVMC 17.24.050 Minimum lot width 60 ft MVMC 17.24.050(B) Minimum lot depth 80 ft MVMC 17.24.050(B) Minimum frontage 30 ft MVMC 17.24.050(B) Maximum units per lot Not set MVMC 16.04.030 | |
| Subdivision MVMC 16.08.020(A) | H | 10 or more MVMC 16.04.010(D) | Minimum lot size Not set MVMC 17.24.050 Minimum lot width 60 ft MVMC 17.24.050(B) Minimum lot depth 80 ft MVMC 17.24.050(B) Minimum frontage 30 ft MVMC 17.24.050(B) Maximum units per lot Not set MVMC 16.04.030 | |
| Duplex and townhouse developments creating nine (or fewer) lots, tracts or parcels MVMC 16.34.025(A); 16.32.020(A)Only for: Dwelling, Two-Family or Duplex, Townhouse | A | up to 9 MVMC 16.34.025(A) | Minimum lot size Not set MVMC 16.34.030 Minimum lot width 20 ft MVMC 16.34.030(C) Minimum lot depth Not set MVMC 16.34.030 Minimum frontage Not set MVMC 16.34.030 Maximum units per lot 1 unit MVMC 16.34.030(A) | |
| Duplex and townhouse developments creating more than nine lots, tracts or parcels MVMC 16.34.025(B); 16.08.020(A)Only for: Dwelling, Two-Family or Duplex, Townhouse | H | 10 or more MVMC 16.34.025(B) | Minimum lot size Not set MVMC 16.34.030 Minimum lot width 20 ft MVMC 16.34.030(C) Minimum lot depth Not set MVMC 16.34.030 Minimum frontage Not set MVMC 16.34.030 Maximum units per lot 1 unit MVMC 16.34.030(A) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- All of these are true:
- The property is within 2,640 feet (straight line from the closest property line) of three of these four facilities, each entirely within that distance - Skagit Transit service, a principal arterial road, a food resource (a retail food store of at least 12,000 gross sq ft), a service provider
- The city has made a financial commitment to participate in the purchase of the property, or to assist with funding infrastructure improvements serving it
- The PSH facility stays affordable to those earning 50 percent or less of the area median income for at least 50 years after its final certificate of occupancy
- Floor area of all units is less than 12,000
- Floor area of all units is more than 12,000
- None of these is true:
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- At least 50 percent of the required parking spaces are located in an enclosed area beneath the habitable floors of the building or complex
- All of these are true:
- At least 50 percent of the required parking spaces are located in an enclosed area beneath the habitable floors of the building or complex
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- The lot fronts an arterial street
- None of these is true:
- The lot fronts an arterial street
- It is not true that the lot fronts an arterial street
- All of these are true:
- The side or rear property line is adjacent to a single-family residential zone
- The lot fronts an arterial street
- All of these are true:
- Building stories is at most 1
- The lot fronts an arterial street
- The side or rear property line is adjacent to a single-family residential zone
- All of these are true:
- Building stories is at least 2
- The lot fronts an arterial street
- The side or rear property line is adjacent to a single-family residential zone
- None of these is true:
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- Parking is provided beneath the habitable stories
- All of these are true:
- Parking is provided beneath the habitable stories
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- Bedrooms in one unit is less than 1
- All of these are true:
- Bedrooms in one unit is at least 1
- Bedrooms in one unit is less than 2
- Bedrooms in one unit is at least 2
- None of these is true:
- The duplex or two-unit townhome is part of a larger multifamily development on the same property
- All of these are true:
- The duplex or two-unit townhome is part of a larger multifamily development on the same property
- Bedrooms in one unit is less than 1
- All of these are true:
- The duplex or two-unit townhome is part of a larger multifamily development on the same property
- Bedrooms in one unit is at least 1
- Bedrooms in one unit is less than 2
- All of these are true:
- The duplex or two-unit townhome is part of a larger multifamily development on the same property
- Bedrooms in one unit is at least 2