R-2 · R-2 Duplex and Townhouse Residential District
Mount Vernon, WA · MVMC 17.18 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Dwelling, Single-Family | Home✓ ADU✓ | — | — | — | — |
| Dwelling, Two-Family or Duplex | — | Home✓ ADU— | — | — | — |
| Townhouse | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Dwelling, Multifamily | — | — | — | ||
| Permanent supportive housing facility | — | — | — | — | |
| Group home | — | — | — | — | Home✓ ADU✓ |
| Shelter care facility | — | — | — | — | Home✓ ADU— |
| Specialized housing for the elderly | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set MVMC 17.18.050 | 35 units MVMC 17.73.040(C)(6)
for Dwelling, Multifamily (4+ units)1 80 units MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)2 |
| Minimum units | Not set MVMC 17.18.050 | 36 units MVMC 17.73.040(C)(6)
for Dwelling, Multifamily (4+ units)1 |
| Minimum lot size | 6,500 sq ft MVMC 17.18.050 | 4,500 sq ft MVMC 17.18.050
for Dwelling, Single-Family (1 unit); Group home (group living); Shelter care facility (group living) No limit MVMC 17.73.040(C)(4)
for Dwelling, Multifamily (3, 4+ units)1 Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)2 435,600 sq ft MVMC 17.18.040(E)(1)
for Specialized housing for the elderly (group living)3 |
| Minimum lot width | 40 ft MVMC 17.18.050 | 60 ft MVMC 17.18.050
for Dwelling, Two-Family or Duplex (2 units); Townhouse (2, 3, 4+ units) |
| Minimum density | 8 units per acre MVMC 17.18.010 | No limit MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)2 Not set MVMC 17.18.020(A); 17.15.030(B)
for Group home (group living); Shelter care facility (group living); Specialized housing for the elderly (group living)3 |
| Maximum density | 20 units per acre, on the net lot area MVMC 17.73.040(A)
for Dwelling, Multifamily (3, 4+ units)1 No limit MVMC 17.67.030(B)
for Permanent supportive housing facility (4+ units)2 Not set MVMC 17.18.020(A); 17.15.030(B)
for Group home (group living); Shelter care facility (group living); Specialized housing for the elderly (group living)3 | |
| Maximum residents | Not set MVMC 17.06.190 | 8 persons MVMC 17.06.070
for Group home (group living) |
| Maximum sleeping units | Not set MVMC 17.18.020(A); 17.15.030(B) | 100 sleeping units MVMC 17.18.040(E)(3)
for Specialized housing for the elderly (group living)3 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | for Dwelling, Two-Family or Duplex (2 units); Townhouse (2, 3, 4+ units) | |
| Side setback | 5 ft MVMC 17.18.060(A)(2) | for Dwelling, Two-Family or Duplex (2 units); Townhouse (2, 3, 4+ units) for Dwelling, Multifamily (3, 4+ units)1 10 ft MVMC 17.67.030(F)(2)
for Permanent supportive housing facility (4+ units)2 |
| Total side setbacks | 15 ft MVMC 17.18.060(A)(2) | for Dwelling, Two-Family or Duplex (2 units); Townhouse (2, 3, 4+ units) Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)2 |
| Street side setback | for Dwelling, Two-Family or Duplex (2 units); Townhouse (2, 3, 4+ units) | |
| Rear setback | 20 ft MVMC 17.18.060(A)(3) | for Dwelling, Two-Family or Duplex (2 units); Townhouse (2, 3, 4+ units) |
| Maximum height | 35 ft MVMC 17.18.060(C) | 50 ft MVMC 17.67.030(F)(4)
for Permanent supportive housing facility (4+ units)2 |
| Maximum stories | 4 stories MVMC 17.67.030(F)(4)
for Permanent supportive housing facility (4+ units)2 2 stories MVMC 17.18.060(C)
for Group home (group living); Shelter care facility (group living); Specialized housing for the elderly (group living)3 | |
| Maximum lot coverage | 35% MVMC 17.18.060(B) | Not set MVMC 17.67.030
for Permanent supportive housing facility (4+ units)2 |
| Minimum parking | 4 spaces per unit MVMC 17.18.080 | The number of parking spaces required to serve a PSH facility shall reflect the proposed uses for such a facility. The applicant will be required to submit a parking study documenting the number of parking spaces needed to provide parking on a site. MVMC 17.67.030(G)
for Permanent supportive housing facility (4+ units)2 The group home has adequate off-street parking and the appearance conforms with the neighborhood. MVMC 17.06.070
for Group home (group living); Shelter care facility (group living) (beds in the project ÷ 5) + employees on the largest shift spaces MVMC 17.84.030(K)
for Specialized housing for the elderly (group living)3 |
| Minimum open space | Not set MVMC 17.18.060 | 15% MVMC 17.67.030(I)
for Permanent supportive housing facility (4+ units)2 20% MVMC 17.18.040(E)(6)
for Specialized housing for the elderly (group living)3 |
| Maximum units per building | Not set MVMC 17.18.060 | 5 units MVMC 17.06.200
for Townhouse (2, 3, 4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit MVMC 17.73.110(B)(2) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 5 ft MVMC 17.18.060(A)(2) | |
| Rear setback | 20 ft MVMC 17.18.060(A)(3) | |
| Maximum height | 35 ft MVMC 17.18.060(C) | |
| Maximum stories | 2 stories MVMC 17.18.060(C) | |
| Minimum parking | the largest of 0, 3 − 4 spaces MVMC 17.73.110(B)(5); 17.18.080 | |
| Maximum unit size | 1,000 sq ft MVMC 17.73.110(B)(4) | |
| Attached to the main house | Not required MVMC 17.73.110(B)(1) | |
| Owner lives on site | Required MVMC 17.73.110(B)(3) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision MVMC 16.32.020(A) | A | up to 9 MVMC 16.04.010(D) | Minimum lot size 4,500 sq ft MVMC 17.18.050 Minimum lot width 40 ft MVMC 17.18.050 Minimum lot depth Not set MVMC 17.18.050 Minimum frontage Not set MVMC 17.18.050 Maximum units per lot Not set MVMC 16.04.030 | |
| Subdivision MVMC 16.08.020(A) | H | 10 or more MVMC 16.04.010(D) | Minimum lot size 4,500 sq ft MVMC 17.18.050 Minimum lot width 40 ft MVMC 17.18.050 Minimum lot depth Not set MVMC 17.18.050 Minimum frontage Not set MVMC 17.18.050 Maximum units per lot Not set MVMC 16.04.030 | |
| Duplex and townhouse developments creating nine (or fewer) lots, tracts or parcels MVMC 16.34.025(A); 16.32.020(A)Only for: Dwelling, Two-Family or Duplex, Townhouse | A | up to 9 MVMC 16.34.025(A) | Minimum lot size Not set MVMC 16.34.030 Minimum lot width 20 ft MVMC 16.34.030(C) Minimum lot depth Not set MVMC 16.34.030 Minimum frontage Not set MVMC 16.34.030 Maximum units per lot 1 unit MVMC 16.34.030(A) | |
| Duplex and townhouse developments creating more than nine lots, tracts or parcels MVMC 16.34.025(B); 16.08.020(A)Only for: Dwelling, Two-Family or Duplex, Townhouse | H | 10 or more MVMC 16.34.025(B) | Minimum lot size Not set MVMC 16.34.030 Minimum lot width 20 ft MVMC 16.34.030(C) Minimum lot depth Not set MVMC 16.34.030 Minimum frontage Not set MVMC 16.34.030 Maximum units per lot 1 unit MVMC 16.34.030(A) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- All of these are true:
- The property is within 2,640 feet (straight line from the closest property line) of three of these four facilities, each entirely within that distance - Skagit Transit service, a principal arterial road, a food resource (a retail food store of at least 12,000 gross sq ft), a service provider
- The city has made a financial commitment to participate in the purchase of the property, or to assist with funding infrastructure improvements serving it
- The PSH facility stays affordable to those earning 50 percent or less of the area median income for at least 50 years after its final certificate of occupancy
- The use has its primary access off a city designated arterial street
- None of these is true:
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- The lot fronts an arterial street
- None of these is true:
- The lot fronts an arterial street
- All of these are true:
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- The lot fronts an arterial street
- None of these is true:
- The lot fronts an arterial street
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- It is not true that the lot fronts an arterial street
- Any of these is true:
- None of these is true:
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- The lot fronts an arterial street
- None of these is true:
- All of these are true:
- The side or rear property line is adjacent to a single-family residential zone
- The lot fronts an arterial street
- All of these are true:
- Building stories is at most 1
- The lot fronts an arterial street
- The side or rear property line is adjacent to a single-family residential zone
- All of these are true:
- Building stories is at least 2
- The lot fronts an arterial street
- The side or rear property line is adjacent to a single-family residential zone
- All of these are true:
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- Building stories is at least 2
- The lot fronts an arterial street
- All of these are true:
- Project uses the affordable housing bonus of Chapter 17.73 (33.3 percent of bonus units affordable)
- Building stories is at most 1
- The lot fronts an arterial street