R-M · R-M multiple residential district
Morton, WA · MMC 17.20 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwellings | Home✓ ADU— | — | — | — | — |
| Government housing | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Designated manufactured homes | — | — | — | — | |
| Two-family dwellings | — | Home✓ ADU— | — | — | — |
| Multiple-family dwellings | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Manufactured home parks | — | — | — | — | |
| Special needs housing | — | — | — | — | Home✓ ADU— |
| Adult family homes | — | — | — | — | Home✓ ADU— |
| Residential care facilities | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 9,000 sq ft MMC 17.20.050(B)(1) | 10,000 + (1,500 × (the largest of main dwelling units on the lot − 2, 0)) sq ft MMC 17.20.050(B)(3)
for Multiple-family dwellings (3, 4+ units); Government housing (3, 4+ units) 130,680 sq ft MMC 17.36.020(A)
for Manufactured home parks (4+ units)2 |
| Minimum lot width | 75 ft MMC 17.20.050(D) | Not set MMC 17.36.040
for Manufactured home parks (4+ units)2 |
| Minimum lot depth | 100 ft MMC 17.20.050(D) | Not set MMC 17.36.040
for Manufactured home parks (4+ units)2 |
| Minimum frontage | Not set MMC 17.20.050 | 40 ft MMC 17.36.040(C)
for Manufactured home parks (4+ units)2 |
| Minimum density | 5 units per acre MMC 17.20.050(A) | |
| Maximum density | 20 units per acre MMC 17.20.050(A) | 1 unit per 3,000 sq ft MMC 17.36.040(B)
for Manufactured home parks (4+ units)2 |
| Minimum development size | Not set MMC 17.20.050 | 130,680 sq ft MMC 17.36.030(A); 17.36.040(A)
for Manufactured home parks (4+ units)2 |
| Maximum residents | Not set MMC 17.08.010 | 15 persons MMC 17.08.010
for Residential care facilities (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
15 ft MMC 17.36.040(D)
for Manufactured home parks (4+ units)2 |
| Side setback | 20 + (the largest of building height − 15, 0) ft MMC 17.20.050(E)(2) | 10 ft MMC 17.36.040(E)
for Manufactured home parks (4+ units)2 |
| Building separation | Not set MMC 17.20 | 10 ft MMC 17.36.030(H)
for Manufactured home parks (4+ units)2 |
| Maximum height | 35 ft MMC 17.20.070 | |
| Maximum lot coverage | 50% MMC 17.20.060 | |
| Minimum parking | 2 spaces per unit MMC 17.20.080; 17.48.030(A)(1) | floor area of all units ÷ 200 spaces MMC 17.20.080; 17.48.030(B)
for Two-family dwellings (2 units); Government housing (2 units) 1 space per unit MMC 17.20.080; 17.48.030(A)(2)
for Multiple-family dwellings (3, 4+ units); Government housing (3, 4+ units) (beds in the project ÷ 3) + (employees on the largest shift ÷ 3) spaces MMC 17.20.080; 17.48.030(A)(6)
for Residential care facilities (group living) |
| Minimum open space | Not set MMC 17.20.050 | the smallest of 5, (10,000 × main dwelling units on the lot) ÷ lot area% MMC 17.20.050(C)
for Multiple-family dwellings (3, 4+ units); Government housing (3, 4+ units) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision MMC 16.20.020 | A10 | 2 to 4 MMC 16.04.030 | — | Minimum lot size 9,000 sq ft MMC 17.20.050(B)(1)-(2) Minimum lot width 75 ft MMC 17.20.050(D) Minimum lot depth 100 ft MMC 17.20.050(D) Minimum frontage Not set MMC 17.20.050 Maximum units per lot Not set MMC 17.20.050 |
| Subdivision MMC 16.08.040; 16.08.050 | H | — | Minimum lot size 9,000 sq ft MMC 17.20.050(B)(1)-(2) Minimum lot width 75 ft MMC 17.20.050(D) Minimum lot depth 100 ft MMC 17.20.050(D) Minimum frontage Not set MMC 17.20.050 Maximum units per lot Not set MMC 17.20.050 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The manufactured home has a manufacture date of not more than five years prior to the date of installation
- Access to the site is over an arterial or collector street
- None of these is true:
- The Washington State Department of Social and Health Services determines that the home and the provider can serve up to six adults
- The Washington State Department of Social and Health Services determines that the home and the provider can serve up to six adults
- The lot's required parking and garage are accessible only from a rear alley
- All of these are true:
- At least 50 percent of the lots which front the street are improved with structures, and not all such lots have the minimum front yard
- The lot's required parking and garage are accessible only from a rear alley
- None of these is true:
- The lot's required parking and garage are accessible only from a rear alley
- At least 50 percent of the lots which front the street are improved with structures, and not all such lots have the minimum front yard
- None of these is true:
- The park provides substantial recreational facilities, such as a recreational building, swimming pool or tennis courts
- The park provides substantial recreational facilities, such as a recreational building, swimming pool or tennis courts
- None of these is true:
- The division contains dedications of streets, alleys, easements or land for public use
- The division contains dedications of streets, alleys, easements or land for public use