MDR · MDR – Medium Density Residential
Mill Creek, WA · MCMC 17.12 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-unit dwellings | Home✓ ADU✓ | — | — | — | — |
| Duplexes | — | Home✓ ADU✓ | — | — | — |
| Townhouses | — | Home✓ ADU✓ | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Multi-unit dwellings | — | — | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Adult family homes | — | — | — | — | Home✓ ADU✓ |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | Home✓ ADU— |
| Boarding houses | — | — | — | — | Home✓ ADU— |
| Retirement homes | — | — | — | — | HomeA ADU— |
| Nursing homes | — | — | — | — | HomeA ADU— |
| Congregate care facilities | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 3,600 sq ft MCMC 17.12.060 | |
| Minimum density | 5 units per acre MCMC 17.12.070(A); 17.22.150(A) | Not set MCMC 17.12
for Adult family homes (group living); Permanent supportive housing (group living); Transitional housing (group living); Boarding houses (group living); Retirement homes (group living); Nursing homes (group living); Congregate care facilities (group living) |
| Maximum density | Not set MCMC 17.12 | the largest of 12, 87,120 ÷ lot area minus critical areas and buffers units per acre, on the net lot area MCMC 17.12.070(B); 17.22.150(A)(1)-(2); 17.22.150(B)(1)
for Single-unit dwellings (1 unit) the largest of 12, 87,120 ÷ lot area minus critical areas and buffers units per acre, ADUs included, on the net lot area MCMC 17.12.070(B); 17.22.150(A)(1)-(2); 17.22.150(B)(1)
for Duplexes (2 units); Townhouses (2, 3, 4+ units); Multi-unit dwellings (3, 4+ units) |
| Maximum sleeping units | Not set MCMC 17.12 | 4 × (the largest of (12 × lot area minus critical areas and buffers) ÷ 43,560, 2), rounded down sleeping units MCMC 17.12.070(B); 17.22.150(A)(1)-(2); 17.22.150(B)(1); 17.22.150(B)(3)
for Boarding houses (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft MCMC 17.12.080(A)(1) | |
| Maximum front setback | 20 ft MCMC 17.12.080(A)(1) | |
| Side setback | Side yard: 10 feet between the ends of buildings for duplexes, 15 feet between the ends of buildings containing three or more units. MCMC 17.12.080(B)(2) | 0 ft MCMC 17.12.080(A)(2)
for Single-unit dwellings (1 unit); Adult family homes (group living) |
| Total side setbacks | Not set MCMC 17.12 | 10 ft MCMC 17.12.080(A)(2)
for Single-unit dwellings (1 unit); Adult family homes (group living) |
| Rear setback | ||
| Building separation | 15 ft MCMC 17.12.080(B)(2) | Not set MCMC 17.12
for Single-unit dwellings (1 unit); Adult family homes (group living) 10 ft MCMC 17.12.080(B)(2)
for Duplexes (2 units); Townhouses (2 units) |
| Maximum height | 35 ft MCMC 17.12.100 | |
| Maximum lot coverage | 60% MCMC 17.12.090(C) | 40% MCMC 17.12.090(A)
for Single-unit dwellings (1 unit); Adult family homes (group living) 50% MCMC 17.12.090(B)
for Duplexes (2 units); Townhouses (2, 3, 4+ units) |
| Minimum parking | 2 spaces per unit MCMC 17.27.060(A); Table 17.27.060-1
for Single-unit dwellings (1 unit) for Multi-unit dwellings (3, 4+ units) Any use not specified in MCMC § 17.27.050 through 17.27.060 must meet the requirements of the most similar use as determined by the director. MCMC 17.27.070
for Adult family homes (group living); Permanent supportive housing (group living); Transitional housing (group living); Congregate care facilities (group living) for Boarding houses (group living) Retirement home | 0.5 1 per employee | 0.5 1 per employee | 0.5 1 per employee MCMC 17.27.060(A); Table 17.27.060-1
for Retirement homes (group living) beds in the project ÷ 3 spaces MCMC 17.27.060(A); Table 17.27.060-1
for Nursing homes (group living) | |
| Maximum units per building | 6 units MCMC 17.12.020(B) | Not set MCMC 17.12
for Single-unit dwellings (1 unit) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units MCMC 17.22.130(C); 17.22.150(B)(2) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft MCMC 17.12.080(A)(1); 17.22.130(G) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | 35 ft MCMC 17.12.100; 17.22.130(G) | |
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft MCMC 17.22.130(B); 17.22.050(E) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Plats (preliminary and final plats) MCMC 16.04.075(A); 17.12.050 | ✓ | Minimum lots Not read MCMC 14.01.030 |
— | Minimum lot size 3,600 sq ft MCMC 17.12.060; 16.02.050 |
| Short subdivisions MCMC 17.12.050; 16.06 | — | — | — | — |
| Unit lot subdivisions MCMC 16.08.030; 16.06.110Only for: Duplexes, Townhouses, Multi-unit dwellings | A | Maximum lots Not read MCMC 14.01.030 |
— | Minimum lot size unit lots may deviate from the following development standards of the underlying zone: 1. Density; 2. Impervious surface coverage; 3. Lot coverage; 4. Lot size; and 5. Setbacks. MCMC 16.08.040(A) |
| Lot size averaging MCMC 16.02.060; 16.04.075(A) | ✓ | — | The total number of lots in the development shall not exceed the maximum density of the land use designation of the comprehensive plan. MCMC 16.02.060(A) Minimum average lot size 3,600 sq ft MCMC 16.02.060(B); MCMC 17.12.060 |
Minimum lot size 0.75 × 3,600 sq ft MCMC 16.02.060(C); MCMC 17.12.060 |
| Planned residential developments (PRD) MCMC 16.12.010(B)(1); 16.12.125(A)-(B) | ✓ | — | 12 units per acre, on the net lot area MCMC 16.12.050(B); 17.12.070(B) Minimum parent area 65,340 sq ft MCMC 16.12.030(B) Area taken out for roads and utilities Subtract from the gross site area all unbuildable land, publicly owned land, commercial and industrial land area and the actual percentage of the gross area devoted to the street system up to a maximum of 20 percent of the gross site area. MCMC 16.12.050(A) |
Minimum lot size Planned area developments may include modifications to zoning and subdivision requirements, provided such modifications comply with the purpose of this chapter as stated in MCMC § 16.12.020. MCMC 16.12.040 |
| Binding site plan MCMC 16.12.010(C); 16.12.125(A)-(B); 17.12.050 | ✓ | Minimum lots Not set MCMC 16.12 |
— | Minimum lot size 3,600 sq ft MCMC 17.12.060; 16.02.050 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The rear yard is on the perimeter of the project (not a platted lot inside the project)
- The rear yard is on the perimeter of the project (not a platted lot inside the project)
- Any of these is true:
- A major transit stop is within 1/2 mile walking distance of the lot
- A major transit stop is within 1/4 mile walking distance of the lot
- All of these are true:
- Lot area is at most 6,000 sf
- A major transit stop is within 1/2 mile walking distance of the lot
- A major transit stop is within 1/4 mile walking distance of the lot
- All of these are true:
- Lot area is more than 6,000 sf
- A major transit stop is within 1/2 mile walking distance of the lot
- A major transit stop is within 1/4 mile walking distance of the lot
- All of these are true:
- Bedrooms in one unit is at most 1
- A major transit stop is within 1/4 mile walking distance of the lot
- All of these are true:
- Bedrooms in one unit is at most 1
- A major transit stop is within 1/4 mile walking distance of the lot
- All of these are true:
- Bedrooms in one unit is 2
- A major transit stop is within 1/4 mile walking distance of the lot
- All of these are true:
- Bedrooms in one unit is 2
- A major transit stop is within 1/4 mile walking distance of the lot
- Bedrooms in one unit is at least 3
- None of these is true:
- A major transit stop is within 1/2 mile walking distance of the lot
- A major transit stop is within 1/4 mile walking distance of the lot
- The accessory dwelling unit is sited at a lot line that abuts a public alley
- None of these is true:
- The accessory dwelling unit is sited at a lot line that abuts a public alley
- None of these is true:
- The accessory dwelling unit is sited at a lot line that abuts a public alley
- The rear yard is on the perimeter of the project (not a platted lot inside the project)
- All of these are true:
- The rear yard is on the perimeter of the project (not a platted lot inside the project)
- The accessory dwelling unit is sited at a lot line that abuts a public alley