Sign in

R-15 · Single-Family

Mercer Island, WA · MICC 19.02 · Official code

By right: 1 unit, 2 units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwelling
Home✓ ADU✓
————
Duplexes—
Home✓ ADU✓
———
Townhouses—
Home✓ ADU✓
Home✓1 ADU✓1
Home✓1 ADU✓1
—
Stacked flats—
Home✓ ADU✓
Home✓1 ADU✓1
Home✓1 ADU✓1
—
Courtyard apartments—
Home✓ ADU✓
Home✓1 ADU✓1
Home✓1 ADU✓1
—
Triplexes——
Home✓1 ADU✓1
——
Fourplexes———
Home✓1 ADU✓1
—
Retirement homes———
HomeH2 ADU—
—
Special needs group housing————
Home✓ ADU—
Social service transitional housing————
Home✓3 H4 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units4 units, ADUs included MICC 19.02.025(E)(1)(b)-(d)
2 units, ADUs included MICC 19.02.025(E)(1)(a); 19.02.025(E)(1)(d)
for Duplexes (2 units); Townhouses (2 units); Stacked flats (2 units); Courtyard apartments (2 units)
The number of dwelling units shall be determined by the planning commission upon examination of the following factors MICC 19.02.010(C)(6)(c); 19.02.010(C)(6)(c)(i)-(iv)
for Retirement homes (4+ units)2
Minimum lot size15,000 sq ft MICC 19.02.020(A)
Minimum lot width90 ft MICC 19.02.020(A)
Minimum lot depth80 ft MICC 19.02.020(A)
Minimum frontageNo building will be permitted on a lot that does not front onto a street acceptable to the city as substantially complying with the standards established for streets. MICC 19.02.020(B)
Maximum densityNot set MICC 19.02.020
The number of dwelling units shall be determined by the planning commission upon examination of the following factors MICC 19.02.010(C)(6)(c)
for Retirement homes (4+ units)2
Maximum residentsThe facility shall comply with all applicable construction codes set forth in MICC title 17, including maximum occupancy restrictions. MICC 19.06.080(A)(1)(b)
Maximum sleeping unitsNot set MICC 19.02.020
The city shall determine the number of dwelling units or occupancy rooms or suites permitted in the proposed facility MICC 19.06.080(B)(3)(i); 19.06.080(B)(3)(i)(i)-(iii)
for Social service transitional housing (group living)4

3. Building standards

StandardValueExceptions
Front setback20 ft MICC 19.02.020(C)(1)(a)
35 ft MICC 19.02.010(C)(6)(d)
for Retirement homes (4+ units)2
Side setback
  • 5 ft5 MICC 19.02.020(C)(1)(c)(ii)
  • the largest of 5, 0.33 × (0.17 × lot width) ft6 MICC 19.02.020(C)(1)(c)(i)(b); 19.02.020(C)(1)(c)(ii)
35 ft MICC 19.02.010(C)(6)(d)
for Retirement homes (4+ units)2
Total side setbacks
  • 15 ft5 MICC 19.02.020(C)(1)(c)(i)(a)
  • 0.17 × lot width ft6 MICC 19.02.020(C)(1)(c)(i)(b)
Not set MICC 19.02.010(C)(6)
for Retirement homes (4+ units)2
Street side setback
  • 5 ft5 MICC 19.02.020(C)(2)(a)(ii); 19.02.020(C)(1)(c)(ii)
  • the largest of 5, 0.33 × (0.17 × lot width) ft6 MICC 19.02.020(C)(2)(a)(ii); 19.02.020(C)(1)(c)(i)(b); 19.02.020(C)(1)(c)(ii)
35 ft MICC 19.02.010(C)(6)(d)
for Retirement homes (4+ units)2
Rear setback25 ft MICC 19.02.020(C)(1)(b)
35 ft MICC 19.02.010(C)(6)(d)
for Retirement homes (4+ units)2
Maximum height30 ft MICC 19.02.020(E)(1)
Maximum lot coverage
  • 40%7 MICC 19.02.020(F)(3)(a)
  • 35%8 MICC 19.02.020(F)(3)(a)
  • 30%9 MICC 19.02.020(F)(3)(a)
  • 20%10 MICC 19.02.020(F)(3)(a)
20% MICC 19.02.010(C)(6)(a)
for Retirement homes (4+ units)2
Maximum impervious surfaceNot set MICC 19.02.020
  • 40%7 MICC 19.02.010(C)(6)(a); 19.02.060(B)
  • 35%8 MICC 19.02.010(C)(6)(a); 19.02.060(B)
  • 30%9 MICC 19.02.010(C)(6)(a); 19.02.060(B)
  • 20%10 MICC 19.02.010(C)(6)(a); 19.02.060(B)
for Retirement homes (4+ units)2
Maximum floor area ratio
  • the smallest of 0.45, 3,000 ÷ lot area11 MICC 19.02.020(D)(3)(a)
  • the smallest of 0.4, 12,000 ÷ lot area12 MICC 19.02.020(D)(1)(d)
Minimum parking
  • 0 spaces per unit13 MICC 19.02.025(G)(1)(a)
  • 1 space per unit14 MICC 19.02.025(G)(1)(b)
  • 2 spaces per unit15 MICC 19.02.025(G)(1)(c)
  • 3 spaces per unit16 MICC 19.02.020(G)(2)(a)
  • 2 spaces per unit17 MICC 19.02.020(G)(2)(b)
  • 0 spaces per unit18 MICC 19.02.020(G)(10)
for Single-family dwelling (1 unit)
0.5 spaces per unit MICC 19.02.010(C)(6)(e)
for Retirement homes (4+ units)2
Except as otherwise provided in this chapter, each lot shall provide parking deemed sufficient by the code official for the use occurring on the lot MICC 19.02.020(G)(4)
for Special needs group housing (group living); Social service transitional housing (group living)3
The facility has adequate off-street parking. The code official may require the applicant to submit a traffic study. MICC 19.06.080(B)(3)(h)
for Social service transitional housing (group living)4
Minimum open space
  • 60%7 MICC 19.02.020(F)(3)(a)
  • 65%8 MICC 19.02.020(F)(3)(a)
  • 70%9 MICC 19.02.020(F)(3)(a)
  • 80%10 MICC 19.02.020(F)(3)(a)
Not set MICC 19.02.010(C)(6)
for Retirement homes (4+ units)2

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units MICC 19.02.030(B)(2)
Minimum lot size15,000 sq ft MICC 19.02.030(B)(1); 19.02.020(A)

Building

StandardValueExceptions
Front setback20 ft MICC 19.02.030(B)(5); 19.02.020(C)(1)(a)
Side setback
  • 5 ft19 MICC 19.02.020(C)(1)(c)(ii)
  • the largest of 5, 0.33 × (0.17 × lot width) ft20 MICC 19.02.020(C)(1)(c)(i)(b); 19.02.020(C)(1)(c)(ii)
  • 0 ft21 MICC 19.02.030(B)(6)
Rear setback
  • 25 ft22 MICC 19.02.030(B)(5); 19.02.020(C)(1)(b)
  • 0 ft21 MICC 19.02.030(B)(6)
Maximum height30 ft MICC 19.02.040(C)(2)(b); 19.02.020(E)(1)
Minimum parking
  • 0 spaces per unit13 MICC 19.02.030(B)(9)(a)
  • 1 space per unit14 MICC 19.02.030(B)(9)(b)
  • 2 spaces per unit15 MICC 19.02.030(B)(9)(c)
Maximum unit size1,000 sq ft MICC 19.02.030(B)(4)
Attached to the main houseNot required MICC 19.02.030(B)(7)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision or short plat MICC 19.08.020(A); 19.15.030 A23 up to 4 MICC 19.16.010
Maximum parent area
174,240 sq ft MICC 19.16.010
Minimum lot size
15,000 sq ft MICC 19.08.030(E)(1); 19.02.020(A)
Minimum lot width
90 ft MICC 19.08.030(E)(1); 19.02.020(A)
Minimum lot depth
80 ft MICC 19.08.030(E)(1); 19.02.020(A)
Long subdivision or long plat MICC 19.08.020(A); 19.15.030 H
Minimum lots
  • 5 lots23 MICC 19.16.010
  • 2 lots24 MICC 19.16.010
—
Minimum lot size
15,000 sq ft MICC 19.08.030(E)(1); 19.02.020(A)
Minimum lot width
90 ft MICC 19.08.030(E)(1); 19.02.020(A)
Minimum lot depth
80 ft MICC 19.08.030(E)(1); 19.02.020(A)
Optional standards for development MICC 19.08.030(G); 19.08.020(A) A25 up to 4 MICC 19.16.010; 19.08.020(A)
Maximum parent area
174,240 sq ft MICC 19.16.010
Minimum lot size
15,000 × 0.75 sq ft MICC 19.08.030(G)(4)
Minimum lot width
90 × 0.75 ft MICC 19.08.030(G)(4)
Minimum lot depth
80 × 0.75 ft MICC 19.08.030(G)(4)
Optional standards for development MICC 19.08.030(G); 19.08.020(A) H25
Minimum lots
  • 5 lots23 MICC 19.16.010
  • 2 lots24 MICC 19.16.010
Maximum lots
The number of lots shall not exceed the number that would otherwise be permitted within the area being subdivided, excluding the shorelands part of any such lot and any part of such lot that is located in a street. MICC 19.08.030(G)(2)
—
Minimum lot size
15,000 × 0.75 sq ft MICC 19.08.030(G)(4)
Minimum lot width
90 × 0.75 ft MICC 19.08.030(G)(4)
Minimum lot depth
80 × 0.75 ft MICC 19.08.030(G)(4)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Any of these is true:
    • Lot is within one-quarter mile walking distance of a major transit stop
    • At least one unit on the lot is affordable housing meeting MICC 19.02.025(F)
  2. Property is used primarily for a place of worship
  3. The facility houses persons with familial status and persons with handicaps within the meaning of the FHAA
  4. All of these are true:
    • The facility is at least 1,000 feet from any other social service transitional housing facility
    • Any of these is true:
      • The facility is at least 600 feet from the property line of educational or recreational facilities where children are known to congregate
      • The facility is a domestic violence shelter
    None of these is true:
    • The facility houses persons with familial status and persons with handicaps within the meaning of the FHAA
  5. Lot width is at most 90 ft
  6. Lot width is more than 90 ft
  7. Slope of the lot: less than 15%, 15% to less than 30%, 30% to 50%, or greater than 50% is under_15
  8. Slope of the lot: less than 15%, 15% to less than 30%, 30% to 50%, or greater than 50% is 15_to_under_30
  9. Slope of the lot: less than 15%, 15% to less than 30%, 30% to 50%, or greater than 50% is 30_to_50
  10. Slope of the lot: less than 15%, 15% to less than 30%, 30% to 50%, or greater than 50% is over_50
  11. Lot area is at most 7,500 sf
  12. Lot area is more than 7,500 sf
  13. Lot is within one-half mile walking distance of a major transit stop
  14. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  15. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  16. All of these are true:
    • Floor area of one unit is at least 3,000
    None of these is true:
    • Compliance with tree retention under chapter 19.10 MICC would make the residential project infeasible if off-street parking were required
  17. All of these are true:
    • Floor area of one unit is less than 3,000
    None of these is true:
    • Compliance with tree retention under chapter 19.10 MICC would make the residential project infeasible if off-street parking were required
  18. Compliance with tree retention under chapter 19.10 MICC would make the residential project infeasible if off-street parking were required
  19. All of these are true:
    • Lot width is at most 90 ft
    • Not all of these are true:
      • The lot line abuts a public alley
      • The accessory dwelling unit is in a detached structure
  20. All of these are true:
    • Lot width is more than 90 ft
    • Not all of these are true:
      • The lot line abuts a public alley
      • The accessory dwelling unit is in a detached structure
  21. All of these are true:
    • The lot line abuts a public alley
    • The accessory dwelling unit is in a detached structure
  22. Not all of these are true:
    • The lot line abuts a public alley
    • The accessory dwelling unit is in a detached structure
  23. Lot area is at most 174,240 sf
  24. Lot area is more than 174,240 sf
  25. All of these are true:
    • Designing the subdivision to MICC 19.08.030(A)-(F) would substantially hinder tree retention, interfere with critical area protection, preclude neighborhood parks or recreation areas, or harm physiographic features or ground cover
    • An area suitable for a private or public open space tract is set aside