PI · Public Institution
Mercer Island, WA · MICC 19.05.010 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwelling | — | — | — | — | |
| Special needs group housing | — | — | — | — | Home✓ ADU— |
| Social service transitional housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | Not set MICC 19.05.010 | 8,400 sq ft MICC 19.02.020(A)
for Single-family dwelling (1 unit)1 |
| Minimum lot width | Not set MICC 19.05.010 | 60 ft MICC 19.02.020(A)
for Single-family dwelling (1 unit)1 |
| Minimum lot depth | Not set MICC 19.05.010 | 80 ft MICC 19.02.020(A)
for Single-family dwelling (1 unit)1 |
| Minimum frontage | Not set MICC 19.05.010 | No building will be permitted on a lot that does not front onto a street acceptable to the city as substantially complying with the standards established for streets. MICC 19.02.020(B)
for Single-family dwelling (1 unit)1 |
| Maximum residents | The facility shall comply with all applicable construction codes set forth in MICC title 17, including maximum occupancy restrictions. MICC 19.06.080(A)(1)(b) | |
| Maximum sleeping units | Not set MICC 19.05.010 | The city shall determine the number of dwelling units or occupancy rooms or suites permitted in the proposed facility MICC 19.06.080(B)(3)(i); 19.06.080(B)(3)(i)(i)-(iii)
for Social service transitional housing (group living)3 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | Not set MICC 19.05.010 | 20 ft MICC 19.02.020(C)(1)(a)
for Single-family dwelling (1 unit)1 |
| Side setback | Not set MICC 19.05.010 | |
| Total side setbacks | Not set MICC 19.05.010 | |
| Street side setback | Not set MICC 19.05.010 | |
| Rear setback | Not set MICC 19.05.010 | 25 ft MICC 19.02.020(C)(1)(b)
for Single-family dwelling (1 unit)1 |
| Maximum height | 36 ft MICC 19.05.010(E) | 30 ft MICC 19.02.020(E)(1)
for Single-family dwelling (1 unit)1 |
| Maximum stories | 3 stories MICC 19.05.010(E) | Not set MICC 19.02.020
for Single-family dwelling (1 unit)1 |
| Maximum lot coverage | Not set MICC 19.05.010 | |
| Maximum floor area ratio | Not set MICC 19.05.010 | |
| Minimum parking | Not set MICC 19.05.010 | for Single-family dwelling (1 unit)1 The facility has adequate off-street parking. The code official may require the applicant to submit a traffic study. MICC 19.06.080(B)(3)(h)
for Social service transitional housing (group living)3 |
| Minimum open space | Not set MICC 19.05.010 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units MICC 19.02.030(B)(2) | |
| Minimum lot size | 8,400 sq ft MICC 19.02.030(B)(1); 19.02.020(A) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft MICC 19.02.030(B)(5); 19.02.020(C)(1)(a) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | 30 ft MICC 19.02.040(C)(2)(b); 19.02.020(E)(1) | |
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft MICC 19.02.030(B)(4) | |
| Attached to the main house | Not required MICC 19.02.030(B)(7) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision or short plat MICC 19.08.020(A); 19.15.030 | A21 | up to 4 MICC 19.16.010 | Maximum parent area 174,240 sq ft MICC 19.16.010 |
|
| Long subdivision or long plat MICC 19.08.020(A); 19.15.030 | H | — |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Land is owned by the Mercer Island School District and is not used for a public school
- The facility houses persons with familial status and persons with handicaps within the meaning of the FHAA
- All of these are true:
- The facility is at least 1,000 feet from any other social service transitional housing facility
- Any of these is true:
- The facility is at least 600 feet from the property line of educational or recreational facilities where children are known to congregate
- The facility is a domestic violence shelter
- The facility houses persons with familial status and persons with handicaps within the meaning of the FHAA
- Lot width is at most 90 ft
- Lot width is more than 90 ft
- Slope of the lot: less than 15%, 15% to less than 30%, 30% to 50%, or greater than 50% is under_15
- Slope of the lot: less than 15%, 15% to less than 30%, 30% to 50%, or greater than 50% is 15_to_under_30
- Slope of the lot: less than 15%, 15% to less than 30%, 30% to 50%, or greater than 50% is 30_to_50
- Slope of the lot: less than 15%, 15% to less than 30%, 30% to 50%, or greater than 50% is over_50
- Lot area is at most 7,500 sf
- Lot area is more than 7,500 sf
- Floor area of one unit is at least 3,000
- Floor area of one unit is less than 3,000
- All of these are true:
- Lot width is at most 90 ft
- Not all of these are true:
- The lot line abuts a public alley
- The accessory dwelling unit is in a detached structure
- All of these are true:
- Lot width is more than 90 ft
- Not all of these are true:
- The lot line abuts a public alley
- The accessory dwelling unit is in a detached structure
- All of these are true:
- The lot line abuts a public alley
- The accessory dwelling unit is in a detached structure
- Not all of these are true:
- The lot line abuts a public alley
- The accessory dwelling unit is in a detached structure
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is at most 6,000 sf
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is more than 6,000 sf
- Lot is within one-half mile walking distance of a major transit stop
- Lot area is at most 174,240 sf
- None of these is true:
- Land is owned by the Mercer Island School District and is not used for a public school
- Lot area is more than 174,240 sf