Sign in

MF-2L · Multiple-Family

Mercer Island, WA · MICC 19.03 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwelling
Home✓ ADU✓
————
Multiple-family dwellings—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Retirement homes———
HomeH1 ADU—
—
Special needs group housing————
Home✓ ADU—
Social service transitional housing————
Home✓2 H3 ADU—
Rooming houses————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set MICC 19.03.010
The number of dwelling units shall be determined by the planning commission upon examination of the following factors MICC 19.02.010(C)(6)(c); 19.02.010(C)(6)(c)(i)-(iv)
for Retirement homes (4+ units)1
Minimum lot width60 ft MICC 19.03.010(F)(3)
Minimum lot depth80 ft MICC 19.03.010(F)(3)
Maximum density26 units per acre MICC 19.03.010(F)(2)
The number of dwelling units shall be determined by the planning commission upon examination of the following factors MICC 19.02.010(C)(6)(c)
for Retirement homes (4+ units)1
Maximum residentsThe facility shall comply with all applicable construction codes set forth in MICC title 17, including maximum occupancy restrictions. MICC 19.06.080(A)(1)(b)
Not set MICC 19.03.010
for Rooming houses (group living)
Maximum sleeping unitsNot set MICC 19.03.010
The city shall determine the number of dwelling units or occupancy rooms or suites permitted in the proposed facility MICC 19.06.080(B)(3)(i); 19.06.080(B)(3)(i)(i)-(iii)
for Social service transitional housing (group living)3

3. Building standards

StandardValueExceptions
Front setback20 ft MICC 19.03.010(G)(1)
Side setback
  • 10 ft4 MICC 19.03.010(G)(3)
  • 20 ft5 MICC 19.03.010(G)(3)
35 ft MICC 19.02.010(C)(6)(d)
for Retirement homes (4+ units)1
Rear setback25 ft MICC 19.03.010(G)(2)
35 ft MICC 19.02.010(C)(6)(d)
for Retirement homes (4+ units)1
Maximum height24 ft MICC 19.03.010(E)(3)(a)
Maximum lot coverage35% MICC 19.03.010(H)
20% MICC 19.02.010(C)(6)(a)
for Retirement homes (4+ units)1
Maximum impervious surfaceNot set MICC 19.03.010
  • 40%6 MICC 19.02.010(C)(6)(a); 19.02.060(B)
  • 35%7 MICC 19.02.010(C)(6)(a); 19.02.060(B)
  • 30%8 MICC 19.02.010(C)(6)(a); 19.02.060(B)
  • 20%9 MICC 19.02.010(C)(6)(a); 19.02.060(B)
for Retirement homes (4+ units)1
Minimum parking
  • 2 spaces per unit10 MICC 19.03.020(B)(1)
  • 0 spaces per unit11 MICC 19.03.020(C)(6)
  • 3 spaces per unit12 MICC 19.02.020(G)(2)(a)
  • 2 spaces per unit13 MICC 19.02.020(G)(2)(b)
  • 0 spaces per unit11 MICC 19.02.020(G)(10)
for Single-family dwelling (1 unit)
0.5 spaces per unit MICC 19.02.010(C)(6)(e)
for Retirement homes (4+ units)1
Not set MICC 19.06.080
for Special needs group housing (group living); Social service transitional housing (group living)2
The facility has adequate off-street parking. The code official may require the applicant to submit a traffic study. MICC 19.06.080(B)(3)(h)
for Social service transitional housing (group living)3
The rooming house does not have adequate off-street parking, which will be determined by a traffic study that shall be promptly provided by the rooming house owner and/or operator if requested by the code official MICC 19.06.080(C)(1)(b)
for Rooming houses (group living)
Minimum open space40% MICC 19.03.010(A)(1); 19.12.040(B)(4)(a)(ii)
Maximum units per building8 units MICC 19.03.010(B)(2)
Not set MICC 19.03.010
for Single-family dwelling (1 unit); Retirement homes (4+ units)1

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units MICC 19.02.030(B)(2)
Minimum lot sizeThe minimum lot size for the principal unit under MICC 19.02.020(A) is satisfied. MICC 19.02.030(B)(1)

Building

StandardValueExceptions
Front setback20 ft MICC 19.02.030(B)(5); 19.03.010(G)(1)
Side setback
  • 10 ft14 MICC 19.03.010(G)(3)
  • 20 ft15 MICC 19.03.010(G)(3)
  • 0 ft16 MICC 19.02.030(B)(6)
Rear setback
  • 25 ft17 MICC 19.02.030(B)(5); 19.03.010(G)(2)
  • 0 ft16 MICC 19.02.030(B)(6)
Maximum height24 ft MICC 19.02.040(C)(2)(b); 19.03.010(E)(3)(a)
Minimum parking
  • 0 spaces per unit18 MICC 19.02.030(B)(9)(a)
  • 1 space per unit19 MICC 19.02.030(B)(9)(b)
  • 2 spaces per unit20 MICC 19.02.030(B)(9)(c)
Maximum unit size1,000 sq ft MICC 19.02.030(B)(4)
Attached to the main houseNot required MICC 19.02.030(B)(7)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision or short plat MICC 19.08.020(A); 19.15.030 A21 up to 4 MICC 19.16.010
Maximum parent area
174,240 sq ft MICC 19.16.010
Minimum lot width
60 ft MICC 19.08.030(E)(1); 19.03.010(F)(3)
Minimum lot depth
80 ft MICC 19.08.030(E)(1); 19.03.010(F)(3)
Long subdivision or long plat MICC 19.08.020(A); 19.15.030 H
Minimum lots
  • 5 lots21 MICC 19.16.010
  • 2 lots22 MICC 19.16.010
—
Minimum lot width
60 ft MICC 19.08.030(E)(1); 19.03.010(F)(3)
Minimum lot depth
80 ft MICC 19.08.030(E)(1); 19.03.010(F)(3)
Optional standards for development MICC 19.08.030(G); 19.08.020(A) A23 up to 4 MICC 19.16.010; 19.08.020(A)
Maximum parent area
174,240 sq ft MICC 19.16.010
Minimum lot width
60 × 0.75 ft MICC 19.08.030(G)(4)
Minimum lot depth
80 × 0.75 ft MICC 19.08.030(G)(4)
Optional standards for development MICC 19.08.030(G); 19.08.020(A) H23
Minimum lots
  • 5 lots21 MICC 19.16.010
  • 2 lots22 MICC 19.16.010
Maximum lots
The number of lots shall not exceed the number that would otherwise be permitted within the area being subdivided, excluding the shorelands part of any such lot and any part of such lot that is located in a street. MICC 19.08.030(G)(2)
—
Minimum lot width
60 × 0.75 ft MICC 19.08.030(G)(4)
Minimum lot depth
80 × 0.75 ft MICC 19.08.030(G)(4)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Property is used primarily for a place of worship
  2. The facility houses persons with familial status and persons with handicaps within the meaning of the FHAA
  3. All of these are true:
    • The facility is at least 1,000 feet from any other social service transitional housing facility
    • Any of these is true:
      • The facility is at least 600 feet from the property line of educational or recreational facilities where children are known to congregate
      • The facility is a domestic violence shelter
    None of these is true:
    • The facility houses persons with familial status and persons with handicaps within the meaning of the FHAA
  4. The side yard is adjacent to an MF, B, CO, PBZ or TC zone
  5. None of these is true:
    • The side yard is adjacent to an MF, B, CO, PBZ or TC zone
  6. Slope of the lot: less than 15%, 15% to less than 30%, 30% to 50%, or greater than 50% is under_15
  7. Slope of the lot: less than 15%, 15% to less than 30%, 30% to 50%, or greater than 50% is 15_to_under_30
  8. Slope of the lot: less than 15%, 15% to less than 30%, 30% to 50%, or greater than 50% is 30_to_50
  9. Slope of the lot: less than 15%, 15% to less than 30%, 30% to 50%, or greater than 50% is over_50
  10. None of these is true:
    • Compliance with tree retention under chapter 19.10 MICC would make the residential project infeasible if off-street parking were required
  11. Compliance with tree retention under chapter 19.10 MICC would make the residential project infeasible if off-street parking were required
  12. All of these are true:
    • Floor area of one unit is at least 3,000
    None of these is true:
    • Compliance with tree retention under chapter 19.10 MICC would make the residential project infeasible if off-street parking were required
  13. All of these are true:
    • Floor area of one unit is less than 3,000
    None of these is true:
    • Compliance with tree retention under chapter 19.10 MICC would make the residential project infeasible if off-street parking were required
  14. All of these are true:
    • The side yard is adjacent to an MF, B, CO, PBZ or TC zone
    • Not all of these are true:
      • The lot line abuts a public alley
      • The accessory dwelling unit is in a detached structure
  15. All of these are true:
    • Not all of these are true:
      • The lot line abuts a public alley
      • The accessory dwelling unit is in a detached structure
    None of these is true:
    • The side yard is adjacent to an MF, B, CO, PBZ or TC zone
  16. All of these are true:
    • The lot line abuts a public alley
    • The accessory dwelling unit is in a detached structure
  17. Not all of these are true:
    • The lot line abuts a public alley
    • The accessory dwelling unit is in a detached structure
  18. Lot is within one-half mile walking distance of a major transit stop
  19. All of these are true:
    • Lot area is at most 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  20. All of these are true:
    • Lot area is more than 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop
  21. Lot area is at most 174,240 sf
  22. Lot area is more than 174,240 sf
  23. All of these are true:
    • Designing the subdivision to MICC 19.08.030(A)-(F) would substantially hinder tree retention, interfere with critical area protection, preclude neighborhood parks or recreation areas, or harm physiographic features or ground cover
    • An area suitable for a private or public open space tract is set aside