R-2 · R-2 two-family residential zoning district
Medical Lake, WA · MLMC 17.20 · Official code
By right: 1 unit, 2 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| One single-family building per lot / single-family dwellings | Home✓ ADU— | Home✓ ADU— | — | — | — |
| Single-family manufactured homes, each not less than twenty-four feet wide by thirty-six feet in length | Home✓ ADU— | Home✓ ADU— | — | — | — |
| Two-unit (duplex) residential dwelling | — | Home✓ ADU— | — | — | — |
| Planned unit development / planned residential development | — | — | — | HomeH ADU— | — |
| Manufactured home communities | — | — | — | Home✓ ADU— | — |
| Dependent care housing | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | The planning commission may adjust the requirements of this title within a planned unit development site to allow flexibility such as for cluster developments, common open space areas, grouping of parking spaces, or grouping of buildings MLMC 17.34.040
for Planned unit development / planned residential development (4+ units) Not set MLMC 18.15.030
for Manufactured home communities (4+ units) | |
| Minimum lot width | The planning commission may adjust the requirements of this title within a planned unit development site to allow flexibility such as for cluster developments, common open space areas, grouping of parking spaces, or grouping of buildings MLMC 17.34.040
for Planned unit development / planned residential development (4+ units) Not set MLMC 18.15.030
for Manufactured home communities (4+ units) | |
| Minimum frontage | The planning commission may adjust the requirements of this title within a planned unit development site to allow flexibility such as for cluster developments, common open space areas, grouping of parking spaces, or grouping of buildings MLMC 17.34.040
for Planned unit development / planned residential development (4+ units) Not set MLMC 18.15.030
for Manufactured home communities (4+ units) | |
| Maximum density | 9.2 units per acre MLMC 17.20.020 | for Planned unit development / planned residential development (4+ units) 10 units per acre MLMC 18.15.030(3); 18.10.090
for Manufactured home communities (4+ units) Not set MLMC 17.20.060
for Dependent care housing (group living) |
| Minimum development size | Not set MLMC 17.20.060 | 87,120 sq ft MLMC 17.20.030(5)
for Planned unit development / planned residential development (4+ units) 130,680 sq ft MLMC 17.20.030(6); 18.15.030(13)
for Manufactured home communities (4+ units) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft MLMC 17.20.060(2)(A) | |
| Side setback | 5 ft MLMC 17.20.060(2)(B) | |
| Street side setback | 10 ft MLMC 17.20.060(2)(C) | 15 ft MLMC 18.15.030(7)
for Manufactured home communities (4+ units) |
| Rear setback | 15 ft MLMC 17.20.060(2)(D) | 5 ft MLMC 18.15.030(7)
for Manufactured home communities (4+ units) |
| Maximum height | 35 ft MLMC 17.20.060(3) | |
| Maximum stories | Not set MLMC 17.20.060 | 1 story MLMC 18.10.160
for Manufactured home communities (4+ units) |
| Maximum lot coverage | 45% MLMC 17.20.060(1)(C) | 70% MLMC 18.15.030(6)
for Manufactured home communities (4+ units) |
| Minimum parking | 2 spaces per unit MLMC 17.20.060(4); 17.36.030(1) | If this chapter does not specify a parking requirement for a specific land use, the planning director shall establish the minimum requirement based on the nearest comparable parking demand. MLMC 17.36.020(c)
for Dependent care housing (group living) |
| Minimum open space | No limit MLMC 17.40.080(2) | Not set MLMC 18.15.030
for Manufactured home communities (4+ units) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short plat MLMC 15.26.060 | A | up to 4 MLMC 15.12.020; 15.26.010 | — | Minimum lot size 9,500 sq ft MLMC 17.20.060(1)(A) Minimum lot width 80 ft MLMC 17.20.060(1)(B) Minimum frontage 60 ft MLMC 17.20.060(1)(B) Maximum units per lot 2 units MLMC 17.20.030(1) |
| Long plat (preliminary plat) MLMC 15.12.040 | H | 5 or more MLMC 15.12.020 | — | Minimum lot size 9,500 sq ft MLMC 17.20.060(1)(A) Minimum lot width 80 ft MLMC 17.20.060(1)(B) Minimum frontage 60 ft MLMC 17.20.060(1)(B) Maximum units per lot 2 units MLMC 17.20.030(1) |
| Binding site plan MLMC 15.27.030; 15.27.020(b) | A7 | Minimum lots Not set MLMC 15.27 Maximum lots Not set MLMC 15.27 |
— | Minimum lot size 9,500 sq ft MLMC 17.20.060(1)(A) Minimum lot width 80 ft MLMC 17.20.060(1)(B) Minimum lot depth Not set MLMC 15.27 Minimum frontage 60 ft MLMC 17.20.060(1)(B) Maximum units per lot 2 units MLMC 17.20.030(1) |
| Residence division MLMC 15.34.020; 15.12.040Only for: Two-unit (duplex) residential dwelling, One single-family building per lot / single-family dwellings | H | 2 to 2 MLMC 15.34.010(a) | — | Minimum lot size 9,500 × 0.5 sq ft MLMC 15.34.030; 17.20.060(1)(A) Minimum lot width Not set MLMC 15.34.030 Minimum lot depth Not set MLMC 15.34.030 Minimum frontage 60 × 0.5 ft MLMC 15.34.030; 17.20.060(1)(B) Maximum units per lot 1 unit MLMC 15.34.010(b); 15.34.040(4) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The lot is a substandard lot created prior to January 1, 1984
- The lot is a substandard lot created prior to January 1, 1984
- None of these is true:
- The planned unit development includes the amenities of MLMC 17.34.070(a)-(i) and asks for bonus density (up to 30 percent over the underlying zone)
- The planned unit development includes the amenities of MLMC 17.34.070(a)-(i) and asks for bonus density (up to 30 percent over the underlying zone)
- The residential lot directly fronts on a community arterial
- None of these is true:
- The residential lot directly fronts on a community arterial
- Any of these is true:
- The improvements will be included in one or more condominiums or owned by an association or other legal entity of the unit owners
- The property is divided for the lease of manufactured homes or travel trailers