WR-R-6-18 WRMFM · Whiskey Ridge, Medium Density Multiple-Family (WR-R-6-18)
Marysville, WA · MMC 22C.010; 22C.010.030(6) · Official code
By right: 1 unit, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single detached | — | — | — | — | |
| Factory-built | — | — | — | — | |
| Mobile home | — | — | — | — | |
| Recreational vehicle | — | — | — | — | |
| Tiny house or tiny house with wheels | — | — | — | — | |
| Middle housing | — | — | |||
| Townhouse | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Multiple-family | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Cottage housing | — | — | — | Home✓ ADU— | — |
| Master planned senior community | — | — | — | Home✓ ADU— | — |
| Senior citizen assisted | — | — | — | — | Home✓ ADU— |
| Adult family home | — | — | — | — | Home✓ ADU— |
| Convalescent, nursing, retirement | — | — | — | — | Home✓ ADU— |
| Residential care facility | — | — | — | — | Home✓ ADU— |
| Transitional housing facilities | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set MMC 22C.010.080(2) | for Middle housing (2 units)4 4 units, ADUs included MMC 22C.010.090(3)(b)(i); 22C.010.090(3)(b)(iv)-(v); 22A.020.140
for Middle housing (3, 4+ units)6 Minimum 4 cottage units. Maximum 12 cottage units per grouping. Development may contain multiple groupings. MMC 22C.010.280(6)
for Cottage housing (4+ units) |
| Minimum units | Not set MMC 22C.010.080(2) | 4 units MMC 22C.010.280(6)
for Cottage housing (4+ units) 20 units MMC 22C.220.030(4)
for Master planned senior community (4+ units) |
| Minimum lot size | Not set MMC 22C.230.070 | 4,000 sq ft MMC 22C.010.090(13)
2,000 × main dwelling units on the lot sq ft MMC 22C.010.280(6); 22C.010.280(6)(b)
for Cottage housing (4+ units) |
| Minimum lot width | 70 ft MMC 22C.010.080(2) | 40 ft MMC 22C.010.090(13)
|
| Minimum density | 10 units per acre MMC 22C.010.080(2); 22C.010.090(19) | Not set MMC 22C.230.070
for Mobile home (1 unit)2; Recreational vehicle (1 unit)3; Tiny house or tiny house with wheels (1 unit)3; Cottage housing (4+ units); Senior citizen assisted (group living); Adult family home (group living); Convalescent, nursing, retirement (group living); Residential care facility (group living); Transitional housing facilities (group living); Permanent supportive housing (group living) |
| Maximum density | Not set MMC 22C.010.080(2) | 6 units per acre, a fraction of 0.5 or more rounds up, on the net lot area MMC 22C.010.090(13); 22C.010.080(2); 22C.010.110(1)
for Single detached (1 unit); Factory-built (1 unit) 8 units per acre MMC 22C.230.050(1)
No limit MMC 22C.010.070(8); 22C.010.110(2)
for Townhouse (3, 4+ units); Multiple-family (3, 4+ units) 12 units per acre, a fraction of 0.5 or more rounds up, on the net lot area MMC 22C.010.280(6); 22C.010.280(6)(a); 22C.010.110(1)
for Cottage housing (4+ units); Master planned senior community (4+ units) 10 units per acre, a fraction of 0.5 or more rounds up, on the net lot area MMC 22C.010.080(2); 22C.010.110(1)
for Senior citizen assisted (group living) |
| Minimum development size | Not set MMC 22C.010.080(2) | |
| Maximum residents | 3 × ((10 × lot area) ÷ 43,560) persons MMC 22C.010.070(2) | 6 persons MMC 22A.020.020
for Adult family home (group living) 15 persons MMC 22A.020.190
for Residential care facility (group living) Not set MMC 22C.010.080(2)
for Transitional housing facilities (group living); Permanent supportive housing (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft MMC 22C.230.070(2)(c)
| |
| Side setback |
|
|
| Street side setback | 20 ft MMC 22C.230.070(2)(c)
| |
| Rear setback |
|
15 ft MMC 22C.230.070(2)(b)
|
| Building separation | Not set MMC 22C.010.080(2) | 10 ft MMC 22C.230.070(4)
6 ft MMC 22C.010.280(6)(e)
for Cottage housing (4+ units) |
| Maximum height |
30 ft MMC 22C.230.070(3)
28 ft MMC 22C.010.280(7)
for Cottage housing (4+ units) | |
| Maximum lot coverage | 40% MMC 22C.010.080(2); 22C.010.090(6) | 50% MMC 22C.010.090(13)
|
| Maximum impervious surface | 70% MMC 22C.010.080(2); 22C.010.090(6) | 65% MMC 22C.010.090(13)
|
| Minimum parking | (2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 4) spaces MMC 22C.230.070(7); 22C.130.030(2)(a)
for Multiple-family (3, 4+ units) 1 space per unit MMC 22C.130.030(2)(a); 22C.220.090(9)(c)
for Master planned senior community (4+ units); Senior citizen assisted (group living) In the case of a use not specifically mentioned in Table 1: Minimum Required Parking Spaces, the requirements for off-street parking shall be determined by the community development director. MMC 22C.130.030(2)(h)
for Adult family home (group living); Residential care facility (group living) (beds in the project ÷ 5) + employees on the largest shift spaces MMC 22C.130.030(2)(a)
for Convalescent, nursing, retirement (group living) the largest of 3, (employees on the largest shift ÷ 2) + (residents ÷ 5) spaces MMC 22C.130.030(2)(a)
for Transitional housing facilities (group living); Permanent supportive housing (group living) | |
| Maximum unit size | Not set MMC 22C.010.080(2) | 1,200 sq ft MMC 22C.010.280(7)
for Cottage housing (4+ units) |
| Maximum lot size | Not set MMC 22C.010.080(2) | |
| Minimum open space | Not set MMC 22C.010.080(2) | 10% MMC 22C.230.070(9)
20% MMC 22C.010.280(8)(a)
for Cottage housing (4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units MMC 22C.185.020(1); 22C.010.090(3)(a)(i) | |
| Minimum lot size | 4,000 sq ft MMC 22C.185.020(1); 22C.010.080(2); 22C.010.090(13) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | ||
| Rear setback | ||
| Maximum height | 30 ft MMC 22C.185.020(1) | |
| Minimum parking | ||
| Maximum unit size | the smallest of the largest of 1,000, 0.5 × floor area of the main house, 1,400 sq ft MMC 22C.185.020(1) | |
| Attached to the main house | Not required MMC 22C.185.020(1) | |
| Owner lives on site | Not required MMC 22C.185.020(1) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision MMC 22G.090.310; 22G.010.160(1)(f) | A | up to 9 MMC 22G.090.310; 22A.020.200 |
Minimum density 10 units per acre MMC 22C.010.080(2); 22C.010.090(19) |
Minimum lot size 4,000 sq ft MMC 22C.010.090(13) Minimum lot width 40 ft MMC 22C.010.090(13) |
| Subdivision MMC 22G.090.120; 22G.010.170(2) | H | 10 or more MMC 22A.020.200 |
Minimum density 10 units per acre MMC 22C.010.080(2); 22C.010.090(19) |
Minimum lot size 4,000 sq ft MMC 22C.010.090(13) Minimum lot width 40 ft MMC 22C.010.090(13) |
| Binding site plan MMC 22G.100.050; 22G.010.160(1)(a) | A | — |
Minimum density 10 units per acre MMC 22C.010.080(2); 22C.010.090(19) |
Minimum lot size 4,000 sq ft MMC 22C.010.090(13) Minimum lot width 40 ft MMC 22C.010.090(13) |
| Unit lot subdivision MMC 22G.095.040(1)(b); 22G.010.160(1)(h)Only for: Single detached, Middle housing, Cottage housing, Townhouse | A | up to 9 MMC 22G.095.040(1)(b) |
Minimum density 10 units per acre MMC 22C.010.080(2); 22C.010.090(19) |
Minimum lot size No limit MMC 22G.095.030(2) Minimum lot width No limit MMC 22G.095.030(2) Minimum frontage No limit MMC 22G.095.030(2) |
| Unit lot subdivision MMC 22G.095.040(1)(a); 22G.090.120Only for: Single detached, Middle housing, Cottage housing, Townhouse | H | 10 or more MMC 22G.095.040(1)(a) |
Minimum density 10 units per acre MMC 22C.010.080(2); 22C.010.090(19) |
Minimum lot size No limit MMC 22G.095.030(2) Minimum lot width No limit MMC 22G.095.030(2) Minimum frontage No limit MMC 22G.095.030(2) |
| Planned residential development MMC 22G.080.050; 22G.010.160(1)(f)Only for: Single detached, Middle housing, Townhouse, Multiple-family | A | up to 9 MMC 22G.090.310; 22A.020.200 |
Minimum parent area 43,560 sq ft MMC 22G.080.030 Minimum density 10 units per acre MMC 22C.010.080(2); 22C.010.090(19) |
Minimum lot size No limit MMC 22G.080.080(1) Minimum lot width 30 ft MMC 22G.080.080(1) |
| Planned residential development MMC 22G.080.050; 22G.090.120Only for: Single detached, Middle housing, Townhouse, Multiple-family | H | 10 or more MMC 22A.020.200 |
Minimum parent area 43,560 sq ft MMC 22G.080.030 Minimum density 10 units per acre MMC 22C.010.080(2); 22C.010.090(19) |
Minimum lot size No limit MMC 22G.080.080(1) Minimum lot width 30 ft MMC 22G.080.080(1) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The lot is in a watershed serving a potable-water reservoir listed as impaired or threatened under Clean Water Act section 303(d) as of July 23, 2023
- The site is an existing mobile/manufactured home park established before June 12, 2008
- The site is an existing (established) mobile/manufactured home park
- None of these is true:
- The lot is in a watershed serving a potable-water reservoir listed as impaired or threatened under Clean Water Act section 303(d) as of July 23, 2023
- The property is within shoreline jurisdiction
- The lot is designated an urban separator by countywide planning policies as of July 23, 2023
- The lot was created through the splitting of a single residential lot
- All of these are true:
- Any of these is true:
- The lot is within one-quarter mile (walking distance) of a major transit stop
- One dedicated affordable housing dwelling unit meeting MMC 22C.010.400 is provided
- The lot is in a watershed serving a potable-water reservoir listed as impaired or threatened under Clean Water Act section 303(d) as of July 23, 2023
- The property is within shoreline jurisdiction
- The lot is designated an urban separator by countywide planning policies as of July 23, 2023
- The lot was created through the splitting of a single residential lot
- The lot is in a watershed serving a potable-water reservoir listed as impaired or threatened under Clean Water Act section 303(d) as of July 23, 2023
- Any of these is true:
- All of these are true:
- Any of these is true:
- The lot is within one-quarter mile (walking distance) of a major transit stop
- One dedicated affordable housing dwelling unit meeting MMC 22C.010.400 is provided
- The lot is in a watershed serving a potable-water reservoir listed as impaired or threatened under Clean Water Act section 303(d) as of July 23, 2023
- The property is within shoreline jurisdiction
- The lot is designated an urban separator by countywide planning policies as of July 23, 2023
- The lot was created through the splitting of a single residential lot
- Any of these is true:
- All of these are true:
- Any of these is true:
- The lot is within one-quarter mile (walking distance) of a major transit stop
- One dedicated affordable housing dwelling unit meeting MMC 22C.010.400 is provided
- Any of these is true:
- The lot is within one-quarter mile (walking distance) of a major transit stop
- One dedicated affordable housing dwelling unit meeting MMC 22C.010.400 is provided
- The lot is in a watershed serving a potable-water reservoir listed as impaired or threatened under Clean Water Act section 303(d) as of July 23, 2023
- The property is within shoreline jurisdiction
- The lot is designated an urban separator by countywide planning policies as of July 23, 2023
- The lot was created through the splitting of a single residential lot
- The lot is in a watershed serving a potable-water reservoir listed as impaired or threatened under Clean Water Act section 303(d) as of July 23, 2023
- Any of these is true:
- None of these is true:
- The lot is within one-quarter mile (walking distance) of a major transit stop
- One dedicated affordable housing dwelling unit meeting MMC 22C.010.400 is provided
- Any of these is true:
- The lot is within one-quarter mile (walking distance) of a major transit stop
- One dedicated affordable housing dwelling unit meeting MMC 22C.010.400 is provided
- None of these is true:
- The project earns bonus units through residential density incentives (Chapter 22C.090 MMC)
- The project earns bonus units through residential density incentives (Chapter 22C.090 MMC)
- The lot adjoins an agricultural zone, inside or outside the city limits
- None of these is true:
- The lot adjoins an agricultural zone, inside or outside the city limits
- All of these are true:
- The cottage development perimeter abuts existing single-family residential development or single-family zoned property (not public right-of-way, not a downtown infill lot)
- The lot adjoins an agricultural zone, inside or outside the city limits
- None of these is true:
- The lot adjoins an agricultural zone, inside or outside the city limits
- The cottage development perimeter abuts existing single-family residential development or single-family zoned property (not public right-of-way, not a downtown infill lot)
- All of these are true:
- The property line abuts the NR-4.5 or NR-6.5 zone (neighborhood residential zoned property)
- The lot adjoins an agricultural zone, inside or outside the city limits
- None of these is true:
- The lot adjoins an agricultural zone, inside or outside the city limits
- The property line abuts the NR-4.5 or NR-6.5 zone (neighborhood residential zoned property)
- All of these are true:
- The side (secondary) street of the corner lot is an arterial
- The lot adjoins an agricultural zone, inside or outside the city limits
- None of these is true:
- The lot adjoins an agricultural zone, inside or outside the city limits
- The side (secondary) street of the corner lot is an arterial
- Portions above the base height provide one extra foot of street and interior setback for each foot above the base height
- None of these is true:
- Portions above the base height provide one extra foot of street and interior setback for each foot above the base height
- The property line abuts the NR-4.5 or NR-6.5 zone (neighborhood residential zoned property)
- None of these is true:
- The property line abuts the NR-4.5 or NR-6.5 zone (neighborhood residential zoned property)
- The housing is located within 1/4 mile of a transit stop (RCW 36.70A.620 parking limits apply)
- None of these is true:
- The housing is located within 1/4 mile of a transit stop (RCW 36.70A.620 parking limits apply)
- The lot is within 1/2 mile walking distance of a major transit stop
- All of these are true:
- Lot area is at most 6,000 sf
- The lot is within 1/2 mile walking distance of a major transit stop
- All of these are true:
- Lot area is more than 6,000 sf
- The lot is within 1/2 mile walking distance of a major transit stop
- All of these are true:
- Bedrooms in one unit is less than 1
- The housing is located within 1/4 mile of a transit stop (RCW 36.70A.620 parking limits apply)
- All of these are true:
- Bedrooms in one unit is 1
- The housing is located within 1/4 mile of a transit stop (RCW 36.70A.620 parking limits apply)
- All of these are true:
- Bedrooms in one unit is at least 2
- The housing is located within 1/4 mile of a transit stop (RCW 36.70A.620 parking limits apply)
- All of these are true:
- The rear lot line abuts an alley
- The lot adjoins an agricultural zone, inside or outside the city limits
- All of these are true:
- Any of these is true:
- Building stories is at most 1
- The project is a planned residential development (PRD) under Chapter 22G.080 MMC
- The lot adjoins an agricultural zone, inside or outside the city limits
- The rear lot line abuts an alley
- Any of these is true:
- None of these is true:
- The lot adjoins an agricultural zone, inside or outside the city limits
- The rear lot line abuts an alley
- Building stories is at most 1
- The project is a planned residential development (PRD) under Chapter 22G.080 MMC
- None of these is true:
- The lot is within 1/2 mile walking distance of a major transit stop