R-MHP · Residential Mobile Home Park (R-MHP)
Marysville, WA · MMC 22C.010; 22C.010.030(7) · Official code
By right: 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single detached | — | — | — | — | |
| Factory-built | — | — | — | — | |
| Mobile home | — | — | — | — | |
| Recreational vehicle | — | — | — | — | |
| Tiny house or tiny house with wheels | — | — | — | — | |
| Mobile/manufactured home park | — | — | — | Home✓ ADU— | — |
| Master planned senior community | — | — | — | HomeA ADU— | — |
| Senior citizen assisted | — | — | — | — | HomeA ADU— |
| Adult family home | — | — | — | — | Home✓ ADU— |
| Transitional housing facilities | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | Not set MMC 22C.230.050 | 20 units MMC 22C.220.030(4)
for Master planned senior community (4+ units) |
| Maximum density | Not set MMC 22C.010.080(2) | 8 units per acre MMC 22C.230.050(1)
As per the underlying zone plus 20%; provided the NR-4.5 zone is capped at 10 units/acre and the NR-6.5 zone is capped at 12 units/acre MMC 22C.220.100(1)(a)
for Master planned senior community (4+ units) |
| Minimum development size | Not set MMC 22C.010.080(2) | |
| Maximum residents | Not set MMC 22C.010.080(2) | Limited to three residents per the equivalent of each minimum lot size or dwelling units per acre allowed in the zone in which it is located. MMC 22C.010.070(2)
for Senior citizen assisted (group living) 6 persons MMC 22A.020.020
for Adult family home (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | Not set MMC 22C.010.080(2) | |
| Side setback | Not set MMC 22C.010.080(2) | 3 ft MMC 22C.230.070(2)(d)
15 ft MMC 22C.230.070(2)(b)
for Mobile/manufactured home park (4+ units) |
| Street side setback | Not set MMC 22C.010.080(2) | |
| Rear setback | Not set MMC 22C.010.080(2) | |
| Building separation | Not set MMC 22C.010.080(2) | |
| Maximum height | Not set MMC 22C.010.080(2) | |
| Maximum impervious surface | Not set MMC 22C.010.080(2) | |
| Minimum parking | (2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 4) spaces MMC 22C.230.070(7); 22C.130.030(2)(a) | 1 space per unit MMC 22C.130.030(2)(a); 22C.220.090(9)(c)
for Master planned senior community (4+ units); Senior citizen assisted (group living) In the case of a use not specifically mentioned in Table 1: Minimum Required Parking Spaces, the requirements for off-street parking shall be determined by the community development director. MMC 22C.130.030(2)(h)
for Adult family home (group living) the largest of 3, (employees on the largest shift ÷ 2) + (residents ÷ 5) spaces MMC 22C.130.030(2)(a)
for Transitional housing facilities (group living); Permanent supportive housing (group living) |
| Maximum lot size | Not set MMC 22C.010.080(2) | |
| Minimum open space | Not set MMC 22C.010.080(2) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units MMC 22C.185.020(1); 22C.010.090(3)(a)(i) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Side setback | 5 ft MMC 22C.185.020(1) | |
| Rear setback | ||
| Maximum height | 30 ft MMC 22C.185.020(1) | |
| Minimum parking | ||
| Maximum unit size | the smallest of the largest of 1,000, 0.5 × floor area of the main house, 1,400 sq ft MMC 22C.185.020(1) | |
| Attached to the main house | Not required MMC 22C.185.020(1) | |
| Owner lives on site | Not required MMC 22C.185.020(1) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision MMC 22G.090.310; 22G.010.160(1)(f) | A | up to 9 MMC 22G.090.310; 22A.020.200 | Not set MMC 22C.010.080(2) | Minimum lot size Not set MMC 22C.010.080(2) |
| Subdivision MMC 22G.090.120; 22G.010.170(2) | H | 10 or more MMC 22A.020.200 | Not set MMC 22C.010.080(2) | Minimum lot size Not set MMC 22C.010.080(2) |
| Binding site plan MMC 22G.100.050; 22G.010.160(1)(a) | A | — | Not set MMC 22C.010.080(2) | Minimum lot size Not set MMC 22C.010.080(2) |
| Unit lot subdivision MMC 22G.095.040(1)(b); 22G.010.160(1)(h)Only for: Single detached | A | up to 9 MMC 22G.095.040(1)(b) | Not set MMC 22C.010.080(2) | Minimum lot size No limit MMC 22G.095.030(2) Minimum lot width No limit MMC 22G.095.030(2) Minimum frontage No limit MMC 22G.095.030(2) |
| Unit lot subdivision MMC 22G.095.040(1)(a); 22G.090.120Only for: Single detached | H | 10 or more MMC 22G.095.040(1)(a) | Not set MMC 22C.010.080(2) | Minimum lot size No limit MMC 22G.095.030(2) Minimum lot width No limit MMC 22G.095.030(2) Minimum frontage No limit MMC 22G.095.030(2) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The lot is an existing single lot of record in the R-MHP zone
- All of these are true:
- The lot is an existing single lot of record in the R-MHP zone
- The lot is in a watershed serving a potable-water reservoir listed as impaired or threatened under Clean Water Act section 303(d) as of July 23, 2023
- The site is an existing mobile/manufactured home park established before June 12, 2008
- The site is an existing (established) mobile/manufactured home park
- The housing is located within 1/4 mile of a transit stop (RCW 36.70A.620 parking limits apply)
- None of these is true:
- The housing is located within 1/4 mile of a transit stop (RCW 36.70A.620 parking limits apply)
- The rear lot line abuts an alley
- All of these are true:
- Any of these is true:
- Building stories is at most 1
- The project is a planned residential development (PRD) under Chapter 22G.080 MMC
- The rear lot line abuts an alley
- Any of these is true:
- None of these is true:
- The rear lot line abuts an alley
- Building stories is at most 1
- The project is a planned residential development (PRD) under Chapter 22G.080 MMC
- The lot is within 1/2 mile walking distance of a major transit stop
- None of these is true:
- The lot is within 1/2 mile walking distance of a major transit stop