F · Flex (F)
Marysville, WA · MMC 22C.080.105; 22C.080.105(3) · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Multiple-family | — | ||||
| Adult family home | — | — | — | — | |
| Residential care facility | — | — | — | — | Home✓ ADU— |
| Enhanced services facility | — | — | — | — | |
| Transitional housing facilities | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
| Emergency housing | — | — | — | — | |
| Emergency shelters – Indoor | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | No limit MMC 22C.080.140(2) | |
| Minimum density | Not set MMC 22C.080.140(2) | 20 units per acre MMC 22C.080.140(2)
for Multiple-family (1, 2, 3, 4+ units)1 |
| Maximum density | Not set MMC 22C.080.140(2) | No limit MMC 22C.080.140(2)
for Multiple-family (1, 2, 3, 4+ units)1 |
| Maximum residents | Not set MMC 22C.080.140(2) | 6 persons MMC 22A.020.020
for Adult family home (group living)2 15 persons MMC 22A.020.190
for Residential care facility (group living) 16 persons MMC 22C.280.060(4)
for Enhanced services facility (group living)3 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft MMC 22C.080.140(2) | |
| Maximum front setback | X See Article IV of this chapter for applicable block frontage standards MMC 22C.080.140(2) | |
| Side setback | ||
| Street side setback | 0 ft MMC 22C.080.140(2) | |
| Rear setback | ||
| Maximum height | ||
| Maximum impervious surface | No limit MMC 22C.080.140(2) | |
| Minimum parking | the largest of 3, (employees on the largest shift ÷ 2) + (residents ÷ 5) spaces MMC 22C.130.030(2)(a) | for Multiple-family (1, 2, 3, 4+ units)1 In the case of a use not specifically mentioned in Table 1: Minimum Required Parking Spaces, the requirements for off-street parking shall be determined by the community development director. MMC 22C.130.030(2)(h)
|
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision MMC 22G.090.310; 22G.010.160(1)(f) | A | up to 9 MMC 22G.090.310; 22A.020.200 | No limit MMC 22C.080.140(2) Minimum density 20 units per acre MMC 22C.080.140(2) |
Minimum lot size No limit MMC 22C.080.140(2) |
| Subdivision MMC 22G.090.120; 22G.010.170(2) | H | 10 or more MMC 22A.020.200 | No limit MMC 22C.080.140(2) Minimum density 20 units per acre MMC 22C.080.140(2) |
Minimum lot size No limit MMC 22C.080.140(2) |
| Binding site plan MMC 22G.100.050; 22G.010.160(1)(a) | A | — | No limit MMC 22C.080.140(2) Minimum density 20 units per acre MMC 22C.080.140(2) |
Minimum lot size No limit MMC 22C.080.140(2) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All dwelling units are located above a street-level (ground-floor) commercial use
- The use is within a single detached dwelling in existence as of September 27, 2021
- The property is shown as eligible for enhanced services facilities on MMC 22C.280.050 Figure 1
- Residents is less than 30
- Residents is at least 30
- The site directly abuts (or is across an alley from) a residential zoning district whose height limit is at least 20 feet less than the subject zone
- None of these is true:
- The site directly abuts (or is across an alley from) a residential zoning district whose height limit is at least 20 feet less than the subject zone
- The rear lot line abuts an alley
- All of these are true:
- The site directly abuts (or is across an alley from) a residential zoning district whose height limit is at least 20 feet less than the subject zone
- The rear lot line abuts an alley
- None of these is true:
- The rear lot line abuts an alley
- The site directly abuts (or is across an alley from) a residential zoning district whose height limit is at least 20 feet less than the subject zone
- None of these is true:
- Portions above the base height provide one extra foot of street and interior setback for each foot above the base height
- All of these are true:
- Portions above the base height provide one extra foot of street and interior setback for each foot above the base height
- The parcel is the SW waterfront parcel depicted in Map 3 of the Downtown Master Plan
- All of these are true:
- Portions above the base height provide one extra foot of street and interior setback for each foot above the base height
- The parcel is the SW waterfront parcel depicted in Map 3 of the Downtown Master Plan
- Bedrooms in one unit is less than 1
- Bedrooms in one unit is 1
- Bedrooms in one unit is at least 2