Sign in

DC · Downtown Core (DC)

Marysville, WA · MMC 22C.080.105; 22C.080.105(1) · Official code

By right: 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Senior citizen assisted—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Multiple-family——
Home✓ ADU—
Home✓ ADU—
—
Townhouse——
Home✓ ADU—
Home✓ ADU—
—
Adult family home————
Home✓1 ADU—
Home, rest, convalescent, or for the aged————
Home✓ ADU—
Residential care facility————
Home✓ ADU—
Enhanced services facility————
Home✓2 ADU—
Transitional housing facilities————
Home✓ ADU—
Permanent supportive housing————
Home✓ ADU—
Emergency housing————
Home✓3 A4 ADU—
Emergency shelters – Indoor————
Home✓3 A4 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit MMC 22C.080.140(2)
Minimum densityNot set MMC 22C.080.140(2)
20 units per acre MMC 22C.080.140(2)
for Senior citizen assisted (2, 3, 4+ units); Multiple-family (3, 4+ units); Townhouse (3, 4+ units)
Maximum densityNot set MMC 22C.080.140(2)
No limit MMC 22C.080.140(2)
for Senior citizen assisted (2, 3, 4+ units); Multiple-family (3, 4+ units); Townhouse (3, 4+ units)
Maximum residentsNot set MMC 22C.080.140(2)
6 persons MMC 22A.020.020
for Adult family home (group living)1
15 persons MMC 22A.020.190
for Residential care facility (group living)
16 persons MMC 22C.280.060(4)
for Enhanced services facility (group living)2

3. Building standards

StandardValueExceptions
Front setback0 ft MMC 22C.080.140(2)
Maximum front setbackX See Article IV of this chapter for applicable block frontage standards MMC 22C.080.140(2)
Side setback
  • 15 ft5 MMC 22C.080.150(2)-(3)
  • 5 ft6 MMC 22C.080.140(2); 22C.080.150(2)
Street side setback0 ft MMC 22C.080.140(2)
Rear setback
  • 0 ft7 MMC 22C.080.150(2)
  • 15 ft8 MMC 22C.080.150(2)-(3)
  • 5 ft9 MMC 22C.080.140(2); 22C.080.150(2)
Maximum height
  • Height may be increased by 1' for each 1' of street and interior setback beyond minimum requirement10 MMC 22C.080.140(2)
  • 85 ft11 MMC 22C.080.140(2)
Maximum impervious surfaceNo limit MMC 22C.080.140(2)
Minimum parkingthe largest of 3, (employees on the largest shift ÷ 2) + (residents ÷ 5) spaces MMC 22C.130.030(2)(a)
1 space per unit MMC 22C.130.030(2)(a)
for Senior citizen assisted (2, 3, 4+ units)
  • 1 space per unit12 MMC 22C.080.230(2)
  • 1.25 spaces per unit13 MMC 22C.080.230(2)
  • 1.5 spaces per unit14 MMC 22C.080.230(2)
for Multiple-family (3, 4+ units)
2 spaces per unit MMC 22C.080.230(2)
for Townhouse (3, 4+ units)
In the case of a use not specifically mentioned in Table 1: Minimum Required Parking Spaces, the requirements for off-street parking shall be determined by the community development director. MMC 22C.130.030(2)(h)
for Adult family home (group living)1; Residential care facility (group living); Enhanced services facility (group living)2
(beds in the project ÷ 5) + employees on the largest shift spaces MMC 22C.130.030(2)(a)
for Home, rest, convalescent, or for the aged (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision MMC 22G.090.310; 22G.010.160(1)(f) A up to 9 MMC 22G.090.310; 22A.020.200 No limit MMC 22C.080.140(2)
Minimum density
20 units per acre MMC 22C.080.140(2)
Minimum lot size
No limit MMC 22C.080.140(2)
Subdivision MMC 22G.090.120; 22G.010.170(2) H 10 or more MMC 22A.020.200 No limit MMC 22C.080.140(2)
Minimum density
20 units per acre MMC 22C.080.140(2)
Minimum lot size
No limit MMC 22C.080.140(2)
Binding site plan MMC 22G.100.050; 22G.010.160(1)(a) A — No limit MMC 22C.080.140(2)
Minimum density
20 units per acre MMC 22C.080.140(2)
Minimum lot size
No limit MMC 22C.080.140(2)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The use is within a single detached dwelling in existence as of September 27, 2021
  2. All of these are true:
    • The property is shown as eligible for enhanced services facilities on MMC 22C.280.050 Figure 1
    • All dwelling units are located above a street-level (ground-floor) commercial use
  3. Residents is less than 30
  4. Residents is at least 30
  5. The site directly abuts (or is across an alley from) a residential zoning district whose height limit is at least 20 feet less than the subject zone
  6. None of these is true:
    • The site directly abuts (or is across an alley from) a residential zoning district whose height limit is at least 20 feet less than the subject zone
  7. The rear lot line abuts an alley
  8. All of these are true:
    • The site directly abuts (or is across an alley from) a residential zoning district whose height limit is at least 20 feet less than the subject zone
    None of these is true:
    • The rear lot line abuts an alley
  9. None of these is true:
    • The rear lot line abuts an alley
    • The site directly abuts (or is across an alley from) a residential zoning district whose height limit is at least 20 feet less than the subject zone
  10. Portions above the base height provide one extra foot of street and interior setback for each foot above the base height
  11. None of these is true:
    • Portions above the base height provide one extra foot of street and interior setback for each foot above the base height
  12. Bedrooms in one unit is less than 1
  13. Bedrooms in one unit is 1
  14. Bedrooms in one unit is at least 2