Sign in

REC · Regional Employment Center

Maple Valley, WA · MVMC 18.30.030; 18.40.040 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Permanent Supportive Housing
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Transitional Housing
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Dormitories————
Home✓1 ADU—
Emergency Housing————
Home✓ ADU—
Emergency Shelters————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsThe number of permanent supportive housing units and transitional housing units allowed on any given property shall be no more than the number of standard dwelling units that would be allowed under the zoning of the property (refer to MVMC § 18.40.030 Table A). MVMC 18.30.030(B)(15)
Maximum densityThe number of permanent supportive housing units and transitional housing units allowed on any given property shall be no more than the number of standard dwelling units that would be allowed under the zoning of the property (refer to MVMC § 18.40.030 Table A). MVMC 18.30.030(B)(15)
Not set MVMC 18.40.040(A)
for Dormitories (group living)1; Emergency Housing (group living); Emergency Shelters (group living)

3. Building standards

StandardValueExceptions
Front setback10 ft MVMC 18.40.040(A)
Side setback
  • 20 ft2 MVMC 18.40.040(A); 18.40.040(B)(3)
  • 0 ft3 MVMC 18.40.040(B)(3)
Street side setback10 ft MVMC 18.40.040(A)
Rear setback
  • 20 ft2 MVMC 18.40.040(A); 18.40.040(B)(3)
  • 0 ft3 MVMC 18.40.040(B)(3)
Maximum height
  • 35 ft4 MVMC 18.40.040(A); 18.40.040(B)(8)
  • 45 ft5 MVMC 18.40.040(A)
Maximum impervious surface80% MVMC 18.40.040(A)
Minimum parking
  • 1 space per unit6 MVMC 18.40.120(B)(1)(c)
  • 2 spaces per unit7 MVMC 18.40.120(B)(1)(c)
  • 1.8 spaces per unit8 MVMC 18.40.120(B)(1)(c)
For uses not specifically identified herein, the amount of parking required shall be determined by the Director, based on parking required for similar uses and, if appropriate, documentation provided by the applicant. MVMC 18.40.120(B)(8)
for Dormitories (group living)1
1 space per sleeping unit MVMC 18.30.060(B)(9); 18.40.120(B)(1)(e)
for Emergency Housing (group living); Emergency Shelters (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision MVMC 18.90.060(A); 18.100.040(A) A 2 to 9 MVMC 18.90.020(B); MVMC 18.90.010(C) "Short subdivision" —
Minimum lot size
Not set MVMC 18.40.040(A)
Minimum lot width
Not set MVMC 18.40.040(A)
Minimum lot depth
Not set MVMC 18.40.040(A)
Minimum frontage
Not set MVMC 18.40.040(A)
Subdivision MVMC 18.90.030(A); 18.100.040(A); 18.100.040(B) H 10 or more MVMC 18.90.010(C) "Subdivision" —
Minimum lot size
Not set MVMC 18.40.040(A)
Minimum lot width
Not set MVMC 18.40.040(A)
Minimum lot depth
Not set MVMC 18.40.040(A)
Minimum frontage
Not set MVMC 18.40.040(A)
Binding site plan MVMC 18.90.080(B); 18.100.040(A) A9 2 to 4 MVMC 18.90.080(B) —
Minimum lot size
Not set MVMC 18.40.040(A)
Minimum lot width
Not set MVMC 18.40.040(A)
Minimum lot depth
Not set MVMC 18.40.040(A)
Minimum frontage
Not set MVMC 18.40.040(A)
Binding site plan MVMC 18.90.080(B); 18.100.040(A) H9 5 or more MVMC 18.90.080(B) —
Minimum lot size
Not set MVMC 18.40.040(A)
Minimum lot width
Not set MVMC 18.40.040(A)
Minimum lot depth
Not set MVMC 18.40.040(A)
Minimum frontage
Not set MVMC 18.40.040(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The residence hall is accessory to a secondary boarding or post-secondary educational institution whose students it houses
  2. The property line abuts a Residential zone
  3. None of these is true:
    • The property line abuts a Residential zone
  4. The structure, or portion of the structure, is within 50 feet of property lines adjoining Residential zones
  5. None of these is true:
    • The structure, or portion of the structure, is within 50 feet of property lines adjoining Residential zones
  6. Bedrooms in one unit is at most 0
  7. All of these are true:
    • Bedrooms in one unit is at least 1
    • Main dwelling units on the lot is at most 50
  8. All of these are true:
    • Bedrooms in one unit is at least 1
    • Main dwelling units on the lot is more than 50
  9. Any of these is true:
    • The site subject to the binding site plan is fully developed
    • The binding site plan is reviewed in conjunction with approval of a commercial site development plan