NB · Neighborhood Business
Maple Valley, WA · MVMC 18.30.030; 18.40.040 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Permanent Supportive Housing | — | ||||
| Transitional Housing | — | ||||
| Dwelling, Multiple-Family | — | — | — | ||
| Congregate Residence | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum density | 12 units per acre MVMC 18.40.040(A); 18.40.030(C)(1); 18.30.030(B)(15) | Not set MVMC 18.40.040(A); 18.30.030(B)(18)
for Congregate Residence (group living)2 |
| Maximum sleeping units | 4 × ((12 × lot area) ÷ 43,560, rounded down) sleeping units MVMC 18.40.040(A); 18.40.030(C)(1); 18.30.030(B)(18) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft MVMC 18.40.040(A) | |
| Side setback | ||
| Street side setback | 10 ft MVMC 18.40.040(A) | |
| Rear setback | ||
| Maximum height | ||
| Maximum impervious surface | 80% MVMC 18.40.040(A) | |
| Minimum parking | 0.25 spaces per sleeping unit MVMC 18.40.120(B)(1)(h)
for Congregate Residence (group living)2 |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision MVMC 18.90.060(A); 18.100.040(A) | A | 2 to 9 MVMC 18.90.020(B); MVMC 18.90.010(C) "Short subdivision" | — | Minimum lot size Not set MVMC 18.40.040(A) Minimum lot width Not set MVMC 18.40.040(A) Minimum lot depth Not set MVMC 18.40.040(A) Minimum frontage Not set MVMC 18.40.040(A) |
| Subdivision MVMC 18.90.030(A); 18.100.040(A); 18.100.040(B) | H | 10 or more MVMC 18.90.010(C) "Subdivision" | — | Minimum lot size Not set MVMC 18.40.040(A) Minimum lot width Not set MVMC 18.40.040(A) Minimum lot depth Not set MVMC 18.40.040(A) Minimum frontage Not set MVMC 18.40.040(A) |
| Binding site plan MVMC 18.90.080(B); 18.100.040(A) | A11 | 2 to 4 MVMC 18.90.080(B) | — | Minimum lot size Not set MVMC 18.40.040(A) Minimum lot width Not set MVMC 18.40.040(A) Minimum lot depth Not set MVMC 18.40.040(A) Minimum frontage Not set MVMC 18.40.040(A) |
| Binding site plan MVMC 18.90.080(B); 18.100.040(A) | H11 | 5 or more MVMC 18.90.080(B) | — | Minimum lot size Not set MVMC 18.40.040(A) Minimum lot width Not set MVMC 18.40.040(A) Minimum lot depth Not set MVMC 18.40.040(A) Minimum frontage Not set MVMC 18.40.040(A) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Residential density is used in conjunction with a permitted principal use, not as stand-alone residential development
- All of these are true:
- Residential density is used in conjunction with a permitted principal use, not as stand-alone residential development
- Residential uses are part of a development and are on the second story and above only
- The property line abuts a Residential zone
- None of these is true:
- The property line abuts a Residential zone
- The structure, or portion of the structure, is within 50 feet of property lines adjoining Residential zones
- None of these is true:
- The structure, or portion of the structure, is within 50 feet of property lines adjoining Residential zones
- Proposal retains more than 20 percent canopy coverage by existing trees, retained near the building, to earn 10 feet of extra height
- All of these are true:
- Proposal retains more than 20 percent canopy coverage by existing trees, retained near the building, to earn 10 feet of extra height
- The structure, or portion of the structure, is within 50 feet of property lines adjoining Residential zones
- Bedrooms in one unit is at most 0
- All of these are true:
- Bedrooms in one unit is at least 1
- Main dwelling units on the lot is at most 50
- All of these are true:
- Bedrooms in one unit is at least 1
- Main dwelling units on the lot is more than 50
- Any of these is true:
- The site subject to the binding site plan is fully developed
- The binding site plan is reviewed in conjunction with approval of a commercial site development plan