Sign in

R-1 · Low Density Residential District

Mabton, WA · MMC 17.12 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwellings, including manufactured homes
Home✓ ADU—
————
Two-family dwellings—
Home✓ ADU—
———
Multifamily dwellings——
Home✓ ADU—
Home✓ ADU—
—
Manufactured home parks———
HomeH ADU—
—
The renting of rooms for lodging purposes only for accommodation and not to exceed four persons————
Home✓ ADU—
Group homes————
Home✓ ADU—
Adult family homes————
Home✓ ADU—
Convalescent nursing homes————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Minimum unitsNot set MMC 17.12
6 units MMC 17.06.020
for Manufactured home parks (4+ units)
Minimum lot size4,000 sq ft MMC 17.12.060(C)(1)
4,000 × main dwelling units on the lot sq ft MMC 17.12.060(C)(2)
for Two-family dwellings (2 units); Multifamily dwellings (3, 4+ units)
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Minimum lot widthNot set MMC 17.12.060(C)(1)
70 ft MMC 17.12.060(C)(2)
for Two-family dwellings (2 units); Multifamily dwellings (3, 4+ units)
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Minimum lot depthNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Minimum frontage30 ft MMC 17.12.050
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Minimum densityNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Maximum densityNot set MMC 17.12
1 unit per 4,000 sq ft MMC 17.12.060(C)(2)
for Two-family dwellings (2 units); Multifamily dwellings (3, 4+ units)
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Minimum development sizeNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Maximum residentsNot set MMC 17.12
4 persons MMC 17.12.020(H)
for The renting of rooms for lodging purposes only for accommodation and not to exceed four persons (group living)
6 persons MMC 17.06.020
for Adult family homes (group living)

3. Building standards

StandardValueExceptions
Front setback20 ft MMC 17.12.070(A)
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Maximum front setbackNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Side setback5 ft MMC 17.12.070(C)(1)
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Total side setbacksNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Street side setback15 ft MMC 17.12.070(C)(2)
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Rear setback15 ft MMC 17.12.070(B)
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Building separationNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Maximum height35 ft MMC 17.12.080
Maximum storiesNot set MMC 17.12.080
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Minimum heightNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Minimum storiesNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Maximum lot coverageNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Maximum impervious surfaceNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Maximum floor area ratioNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Minimum parkingA parking requirement for any use not listed in the preceding sections shall be established by the administrator, based on the requirement for that listed use deemed to be most comparable in terms of parking demand or on standards in the building code. MMC 17.24.110.5; 17.12.090
2 spaces per unit MMC 17.24.110.1.1; 17.12.090
for Single-family dwellings, including manufactured homes (1 unit); Two-family dwellings (2 units)
  • 2 spaces per unit1 MMC 17.24.110.1.3; 17.12.090
  • (32 + (1.5 × (main dwelling units on the lot − 16))) − 0.3, rounded up spaces2 MMC 17.24.110.1.4; 17.24.030.1; 17.12.090
for Multifamily dwellings (3, 4+ units)
Not read manufactured home park ordinance; named in MMC 17.12.020(G); 17.12.090
for Manufactured home parks (4+ units)
(beds in the project ÷ 3) − 0.3, rounded up spaces MMC 17.24.110.1.5; 17.24.030.1; 17.12.090
for Convalescent nursing homes (group living)
Maximum unit sizeNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Maximum building floor areaNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Maximum lot sizeNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Maximum building footprintNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Minimum open spaceNot set MMC 17.12
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)
Maximum units per buildingNot set MMC 17.12
1 unit MMC 17.06.020
for Single-family dwellings, including manufactured homes (1 unit)
2 units MMC 17.06.020
for Two-family dwellings (2 units)
Not read manufactured home park ordinance; named in MMC 17.12.020(G)
for Manufactured home parks (4+ units)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision MMC 19.12.010(A); 19.12.050(B) A up to 4 MMC 19.04.040 —
Minimum lot size
4,000 × main dwelling units on the lot sq ft MMC 17.12.060(A)(1); MMC 17.12.060(A)(2)
Minimum lot width
  • 50 ft3 MMC 17.12.060(B)(1)
  • 70 ft4 MMC 17.12.060(B)(2)
Minimum frontage
30 ft MMC 17.12.050
Subdivision MMC 19.16.060; 17.30.020(C)(1) H 5 or more MMC 19.04.040 —
Minimum lot size
4,000 × main dwelling units on the lot sq ft MMC 17.12.060(A)(1); MMC 17.12.060(A)(2)
Minimum lot width
  • 50 ft3 MMC 17.12.060(B)(1)
  • 70 ft4 MMC 17.12.060(B)(2)
Minimum frontage
30 ft MMC 17.12.050

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Main dwelling units on the lot is at most 16
  2. Main dwelling units on the lot is more than 16
  3. Main dwelling units on the lot is at most 1
  4. Main dwelling units on the lot is more than 1