MH · MH Manufactured Home Zone
Lynden, WA · LMC 19.19 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Manufactured home | Home✓ ADU✓ | — | — | — | — |
| Modular home | Home✓ ADU✓ | — | — | — | — |
| Recreational vehicle | Home✓ ADU— | — | — | — | — |
| Single-family detached dwelling | — | — | — | — | |
| Manufactured home park (or subdivision) | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Adult family home | — | — | — | — | HomeA ADU— |
| Group home | — | — | — | — | HomeA ADU— |
| Permanent supportive housing | — | — | — | — | HomeA ADU— |
| Residential reentry facilities | — | — | — | — | |
| Transitional housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 87,120 sq ft LMC 18.22.050(A); 19.19.120
for Manufactured home park (or subdivision) (2, 3, 4+ units) | |
| Minimum lot width | 45 ft LMC 19.19.070 | Not set LMC 18.22.050
for Manufactured home park (or subdivision) (2, 3, 4+ units) |
| Maximum density | 8 units per acre, a fraction of 0.5 or more rounds up LMC 19.11.020; 19.19.060; 19.11.030(B)-(C) | |
| Minimum development size | Not set LMC 19.19.090 | 87,120 sq ft LMC 18.22.050(A)
for Manufactured home park (or subdivision) (2, 3, 4+ units) |
| Maximum residents | floor area of all units ÷ 350, rounded down persons LMC 19.49.110(C)(2)(a) | Maximum occupancy determined per 19.49.080 (C). LMC 19.49.030; 19.49.080(C)(2)
for Group home (group living) the smallest of 6, floor area of all units ÷ 350, rounded down persons LMC 19.49.100(C)(2)(b); 19.49.100(C)(2)(a)
for Transitional housing (group living)3 |
| Maximum beds | Not set LMC 19.49.030 | 6 beds LMC 19.49.090(C)(2)(a)
for Residential reentry facilities (group living)2 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft LMC 19.19.090 | |
| Side setback | 7 ft LMC 19.19.090 | |
| Total side setbacks | 15 ft LMC 19.19.090 | |
| Street side setback | 15 ft LMC 19.22.020(C)(7) | |
| Rear setback | 15 ft LMC 19.19.090 | |
| Maximum height | 25 ft LMC 19.19.090 | |
| Maximum stories | 2 stories LMC 19.19.090 | |
| Maximum lot coverage | ||
| Maximum impervious surface | ||
| Minimum parking | 2 spaces per unit LMC 19.51.040 | (2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 5, rounded up) spaces LMC 19.19.110
for Manufactured home park (or subdivision) (2, 3, 4+ units) 2 + 1 spaces LMC 19.51.040
for Adult family home (group living) |
| Maximum lot size | Not set LMC 19.19.090 | 871,200 sq ft LMC 18.22.050(B)
for Manufactured home park (or subdivision) (2, 3, 4+ units) |
| Minimum open space | Not set LMC 19.19.090 | 10% LMC 18.22.050(E)
for Manufactured home park (or subdivision) (2, 3, 4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units LMC 19.20.020(A); 19.20.020(C) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft LMC 19.19.090; 19.20.030(B); 19.22.040(B)(1) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | ||
| Maximum stories | ||
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft LMC 19.20.020(D) | |
| Attached to the main house | Not required LMC 19.20.020(B) | |
| Owner lives on site | Not required LMC 19.20.020(G); 19.20.040(E) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision LMC 18.12.010 | A | up to 4 LMC 18.12.010; 17.01.030 | — | Minimum lot width 45 ft LMC 19.19.070 Minimum frontage 50 ft LMC 18.14.020(B) |
| Lot Averaging LMC 18.14.020(G) | A | — | Minimum average lot size 3,600 sq ft LMC 18.14.020(G)(3); 19.19.090 |
Minimum lot size 3,600 × 0.9 sq ft LMC 18.14.020(G)(2) Minimum lot width 45 ft LMC 19.19.070 Minimum frontage 50 ft LMC 18.14.020(B) |
| Mobile/manufactured home subdivision LMC 18.22.040(B); 18.16.020 | H | 2 or more LMC 17.01.030 | 8 units per acre, a fraction of 0.5 or more rounds up LMC 18.22.050(F) Minimum parent area 87,120 sq ft LMC 18.22.050(A) Maximum parent area 871,200 sq ft LMC 18.22.050(B) |
Minimum lot size 3,600 sq ft LMC 18.22.050(D); 19.19.090 Minimum lot width 45 ft LMC 19.19.070 Minimum frontage 50 ft LMC 18.14.020(B) |
| Binding site plan LMC 18.22.040(A); 18.24.050(B); 17.03.040(A)(1)Only for: Manufactured home park (or subdivision) | H | — | 8 units per acre, a fraction of 0.5 or more rounds up LMC 18.22.050(F) Minimum parent area 87,120 sq ft LMC 18.22.050(A) Maximum parent area 871,200 sq ft LMC 18.22.050(B) |
Minimum lot size 3,600 sq ft LMC 18.22.050(D) Minimum lot width 45 ft LMC 19.19.070 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The lot has a site-built detached single family dwelling originally constructed prior to January 1, 2023
- Beds in the project is at most 6
- Residents is at most 6
- Not all of these are true:
- The real property is owned or controlled by a religious organization
- One hundred percent of all single-family or multi-family residential dwelling units within the development are set aside for or are occupied by low-income households
- The development is part of a lease or other binding obligation that requires it to be used exclusively for affordable housing purposes for at least fifty years
- All of these are true:
- The real property is owned or controlled by a religious organization
- One hundred percent of all single-family or multi-family residential dwelling units within the development are set aside for or are occupied by low-income households
- The development is part of a lease or other binding obligation that requires it to be used exclusively for affordable housing purposes for at least fifty years
- None of these is true:
- The adult family home has Washington State DSHS approval to serve up to eight adults
- The adult family home has Washington State DSHS approval to serve up to eight adults
- The ADU is attached, within the existing home or as an addition to it (not a detached structure)
- None of these is true:
- The ADU is attached, within the existing home or as an addition to it (not a detached structure)
- None of these is true:
- The ADU is attached, within the existing home or as an addition to it (not a detached structure)
- The rear lot line abuts a public alley
- All of these are true:
- The rear lot line abuts a public alley
- The ADU is attached, within the existing home or as an addition to it (not a detached structure)
- Lot area is at least 6,000 sf
- Lot area is less than 6,000 sf