Sign in

Industrial · Industrial

Lake Stevens, WA · LSMC 14.36.030 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Apartment(s) above permitted nonresidential use
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Secure community transition facilities————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum frontage20 ft LSMC Table 14.48-II; Table 14.48-II note 8; 14.38.015

3. Building standards

StandardValueExceptions
Front setback20 ft LSMC Table 14.48-II
Side setback
  • 30 ft2 LSMC 14.48.040(b)
  • 10 ft3 LSMC Table 14.48-II
Street side setback10 ft LSMC Table 14.48-II; 14.48.035(a)
Rear setback
  • 30 ft2 LSMC 14.48.040(b)
  • 10 ft3 LSMC Table 14.48-II
Building separation10 ft LSMC Table 14.48-II note 2
Maximum height
  • 80 ft4 LSMC Table 14.48-II note 6; 14.16C.045
  • 55 ft5 LSMC Table 14.48-II
  • 45 ft6 LSMC Table 14.48-II
Minimum parking2 spaces per unit LSMC 14.72.010(e) Table 14.72-I
2.25 spaces per unit LSMC 14.72.010(e) Table 14.72-I
for Apartment(s) above permitted nonresidential use (3, 4+ units)1
1.5 spaces for each staff person on site during the maximum shift plus 1 space for each facility vehicle plus 1 space for every 3 beds. LSMC 14.72.010(e) Table 14.72-I
for Secure community transition facilities (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision (short plat) LSMC 14.18.025(a); Table 14.16A-I A up to 9 LSMC 14.18.010; 14.08.010 —
Minimum frontage
20 ft LSMC Table 14.48-II; Table 14.48-II note 8; 14.38.015
Long subdivision (formal or long plat) LSMC 14.18.025(a); Table 14.16A-I H 10 or more LSMC 14.18.010; 14.08.010 —
Minimum frontage
20 ft LSMC Table 14.48-II; Table 14.48-II note 8; 14.38.015
Binding Site Plans LSMC 14.18.110; Table 14.16A-I A7
Maximum lots
Not set LSMC 14.18.105
—
Minimum lot size
Not set LSMC 14.18.105

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The apartment is above a permitted nonresidential use
  2. The industrial lot shares a boundary with a residentially zoned lot along this lot line
  3. None of these is true:
    • The industrial lot shares a boundary with a residentially zoned lot along this lot line
  4. The project obtains a conditional use permit for a height increase up to 80 feet
  5. All of these are true:
    • The lot is zoned General Industrial (GI), not Light Industrial (LI)
    None of these is true:
    • The project obtains a conditional use permit for a height increase up to 80 feet
  6. None of these is true:
    • The project obtains a conditional use permit for a height increase up to 80 feet
    • The lot is zoned General Industrial (GI), not Light Industrial (LI)
  7. Any of these is true:
    • The division subjects the land to the Horizontal Property Regimes Act or the Condominium Act (condominium units)
    • The commercial or industrial zoned land is divided for sale or lease for commercial or industrial purposes, or leased as a mobile home park