Industrial · Industrial
Lake Stevens, WA · LSMC 14.36.030 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Apartment(s) above permitted nonresidential use | — | ||||
| Secure community transition facilities | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum frontage | 20 ft LSMC Table 14.48-II; Table 14.48-II note 8; 14.38.015 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft LSMC Table 14.48-II | |
| Side setback | ||
| Street side setback | 10 ft LSMC Table 14.48-II; 14.48.035(a) | |
| Rear setback | ||
| Building separation | 10 ft LSMC Table 14.48-II note 2 | |
| Maximum height | ||
| Minimum parking | 2 spaces per unit LSMC 14.72.010(e) Table 14.72-I | 2.25 spaces per unit LSMC 14.72.010(e) Table 14.72-I
for Apartment(s) above permitted nonresidential use (3, 4+ units)1 1.5 spaces for each staff person on site during the maximum shift plus 1 space for each facility vehicle plus 1 space for every 3 beds. LSMC 14.72.010(e) Table 14.72-I
for Secure community transition facilities (group living) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision (short plat) LSMC 14.18.025(a); Table 14.16A-I | A | up to 9 LSMC 14.18.010; 14.08.010 | — | Minimum frontage 20 ft LSMC Table 14.48-II; Table 14.48-II note 8; 14.38.015 |
| Long subdivision (formal or long plat) LSMC 14.18.025(a); Table 14.16A-I | H | 10 or more LSMC 14.18.010; 14.08.010 | — | Minimum frontage 20 ft LSMC Table 14.48-II; Table 14.48-II note 8; 14.38.015 |
| Binding Site Plans LSMC 14.18.110; Table 14.16A-I | A7 | Maximum lots Not set LSMC 14.18.105 |
— | Minimum lot size Not set LSMC 14.18.105 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The apartment is above a permitted nonresidential use
- The industrial lot shares a boundary with a residentially zoned lot along this lot line
- None of these is true:
- The industrial lot shares a boundary with a residentially zoned lot along this lot line
- The project obtains a conditional use permit for a height increase up to 80 feet
- All of these are true:
- The lot is zoned General Industrial (GI), not Light Industrial (LI)
- The project obtains a conditional use permit for a height increase up to 80 feet
- None of these is true:
- The project obtains a conditional use permit for a height increase up to 80 feet
- The lot is zoned General Industrial (GI), not Light Industrial (LI)
- Any of these is true:
- The division subjects the land to the Horizontal Property Regimes Act or the Condominium Act (condominium units)
- The commercial or industrial zoned land is divided for sale or lease for commercial or industrial purposes, or leased as a mobile home park