Sign in

CBD · Central Business District

Lake Stevens, WA · LSMC 14.36.020(b); 14.38.020(e) · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Mixed use multifamily residential units including apartments, condominiums, and live/work units, where the residential units are located above or behind commercial uses——
Home✓1 ADU—
Home✓1 ADU—
—
Permanent Supportive Housing————
Home✓ ADU—
Transitional Housing————
HomeA ADU—
Emergency Shelters————
HomeA ADU—
Emergency Housing————
HomeA ADU—
Co-Living Housing————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit LSMC 14.38.040 Table 14.38-I
Minimum frontage20 ft LSMC Table 14.48-II; Table 14.48-II note 8; 14.38.015

3. Building standards

StandardValueExceptions
Front setback5 ft LSMC 14.38.040 Table 14.38-I
Maximum front setback10 ft LSMC 14.38.040 Table 14.38-I note 1
Side setback0 ft LSMC 14.38.040 Table 14.38-I
Street side setback10 ft LSMC 14.38.040 Table 14.38-I note 5
Rear setback0 ft LSMC 14.38.040 Table 14.38-I
Building separation10 ft LSMC 14.38.040 Table 14.38-I note 5
Maximum height
  • 45 ft2 LSMC 14.38.040 Table 14.38-I note 10
  • 55 ft3 LSMC 14.38.040 Table 14.38-I
Minimum parking
  • 1.25 spaces per unit4 LSMC 14.38.060(b) Table 14.38-III note 5
  • 2.25 spaces per unit5 LSMC 14.38.060(b) Table 14.38-III note 6
Subject to the parking requirements for the associated residential building form/type, as listed in this chapter and defined in Chapter 14.08 LSMC. LSMC 14.72.010(e) Table 14.72-I
for Permanent Supportive Housing (group living); Transitional Housing (group living)
Approval of a project-specific parking analysis is required as part of the required Site Management Plan, per LSMC § 14.44.100(c). LSMC 14.72.010(e) Table 14.72-I; 14.44.100(c)(1)(iii)
for Emergency Shelters (group living); Emergency Housing (group living)
  • 0 spaces per sleeping unit6 LSMC 14.72.010(e) Table 14.72-I
  • 0.25 spaces per sleeping unit7 LSMC 14.72.010(e) Table 14.72-I
for Co-Living Housing (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision (short plat) LSMC 14.18.025(a); Table 14.16A-I A up to 9 LSMC 14.18.010; 14.08.010 —
Minimum frontage
20 ft LSMC Table 14.48-II; Table 14.48-II note 8; 14.38.015
Long subdivision (formal or long plat) LSMC 14.18.025(a); Table 14.16A-I H 10 or more LSMC 14.18.010; 14.08.010 —
Minimum frontage
20 ft LSMC Table 14.48-II; Table 14.48-II note 8; 14.38.015
Binding Site Plans LSMC 14.18.110; Table 14.16A-I A8
Maximum lots
Not set LSMC 14.18.105
—
Minimum lot size
Not set LSMC 14.18.105

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The residential units are located above or behind commercial uses
  2. The lot is west of Main Street between North Lakeshore and 16th Street NE
  3. None of these is true:
    • The lot is west of Main Street between North Lakeshore and 16th Street NE
  4. Bedrooms in one unit is at most 1
  5. Bedrooms in one unit is at least 2
  6. The lot is within one-half mile walking distance of a major transit stop
  7. None of these is true:
    • The lot is within one-half mile walking distance of a major transit stop
  8. Any of these is true:
    • The division subjects the land to the Horizontal Property Regimes Act or the Condominium Act (condominium units)
    • The commercial or industrial zoned land is divided for sale or lease for commercial or industrial purposes, or leased as a mobile home park