Sign in

HIGH DENSITY RESIDENTIAL · High-Density Residential District

Lacey, WA · LMC 16.18 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family detached structures
Home✓ ADUA1 A2 A3
————
Manufactured Home, Designated
Home✓ ADUA1 A2 A3
————
Duplex—
Home✓ ADUA1 A2 A3
———
Townhouse—
HomeA ADU—
HomeA ADU—
HomeA ADU—
—
Triplex——
Home✓ ADUA1 A2 A3
——
Any residential use———
Home✓ ADUA1 A2 A3
—
Cottage housing———
Home✓ ADU—
—
Manufactured home park———
HomeH ADUA1 A2 A3
—
Housing for people with functional disabilities————
Home✓ ADUA1 A2 A3
Co-living housing————
Home✓ ADUA1 A2 A3
Nursing homes, convalescent care facilities————
HomeH ADUA1 A2 A3

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units
  • 3 units, ADUs included1 LMC 16.52.020(A)
  • 4 units, ADUs included2 LMC 16.52.020(A)
  • 6 units, ADUs included3 LMC 16.52.020(A)
Not set LMC 16.18.020(A)(1)
for Any residential use (4+ units); Townhouse (4+ units); Manufactured home park (4+ units)
60 units LMC 16.62.020(B); 16.62.030(O)
for Cottage housing (4+ units)
9 units LMC 16.61.040(A)
for Townhouse (4+ units)
Minimum unitsNot set LMC 16.18.020(A)(1)
4 units LMC 16.62.030(O)
for Cottage housing (4+ units)
10 units LMC 16.61.040(A)
for Townhouse (4+ units)
Minimum lot size
  • 2,000 sq ft4 LMC 16.18.040(A)(1)
  • 3,500 sq ft5 LMC 16.18.040(A)(1)
Lot configurations shall be governed by density, setbacks, open space, and other requirements and guidelines herein. LMC 16.61.030(C)
for Townhouse (2, 3, 4+ units)
Not set LMC 16.18.040(B)
for Any residential use (4+ units); Cottage housing (4+ units); Manufactured home park (4+ units); Co-living housing (group living)
Minimum lot width
  • 30 ft4 LMC 16.18.040(A)(2)
  • 40 ft5 LMC 16.18.040(A)(2)
  • 50 ft6 LMC 16.18.040(A)(2)
  • 30 ft7 LMC 16.18.040(A)(2)
  • 40 ft8 LMC 16.18.040(A)(2)
for Duplex (2 units); Triplex (3 units)
Lot configurations shall be governed by density, setbacks, open space, and other requirements and guidelines herein. LMC 16.61.030(C)
for Townhouse (2, 3, 4+ units)
Not set LMC 16.18.040(B)
for Any residential use (4+ units); Cottage housing (4+ units); Manufactured home park (4+ units); Co-living housing (group living)
Minimum frontage
  • 50 ft6 LMC 16.18.040(A)(2)
  • Not set9 LMC 16.18.040(A)(2)
  • 30 ft10 LMC 16.18.040(A)(2)
  • 40 ft11 LMC 16.18.040(A)(2)
  • Not set9 LMC 16.18.040(A)(2)
for Single-family detached structures (1 unit); Manufactured Home, Designated (1 unit); Housing for people with functional disabilities (group living); Nursing homes, convalescent care facilities (group living)
Not set LMC 16.63.120
for Manufactured home park (4+ units)
Minimum density12 units per acre LMC 16.18.020(A)(1)
Not set LMC 16.18.020(A)(1)
for Housing for people with functional disabilities (group living); Nursing homes, convalescent care facilities (group living)
No limit LMC 16.56.020(B)
for Co-living housing (group living)
Minimum development sizeNot set LMC 16.18.040
130,680 sq ft LMC 16.63.110
for Manufactured home park (4+ units)
Maximum residentsNot set LMC 16.18.040
  • 6 persons12 LMC 16.06.095
  • 15 persons13 LMC 16.06.678
  • Not set14 LMC 16.06.382; 16.06.741
for Housing for people with functional disabilities (group living)

3. Building standards

StandardValueExceptions
Front setback10 ft LMC 16.18.040(A)(3)
16 ft LMC 16.18.040(A)(3)
for Single-family detached structures (1 unit); Manufactured Home, Designated (1 unit); Duplex (2 units); Townhouse (2 units); Housing for people with functional disabilities (group living); Nursing homes, convalescent care facilities (group living)
  • 10 ft15 LMC 16.63.120(D)
  • 15 ft16 LMC 16.63.120(D)
for Manufactured home park (4+ units)
Side setback5 ft LMC 16.18.040(A)(4)
Total side setbacks10 ft LMC 16.18.040(A)(4)
Not set LMC 16.63.120
for Manufactured home park (4+ units)
Rear setback15 ft LMC 16.18.040(A)(6)
Building separationNot set LMC 16.18.040
20 ft LMC 16.61.030(J)
for Townhouse (2, 3, 4+ units)
10 ft LMC 16.62.030(K)
for Cottage housing (4+ units)
Maximum height80 ft LMC 16.18.040(C)(4)
  • 25 ft17 LMC 16.62.030(I)(1)
  • 18 ft18 LMC 16.62.030(I)(2)
for Cottage housing (4+ units)
Maximum lot coverage50% LMC 16.18.040(C)(2)
Not set LMC 16.63.120
for Manufactured home park (4+ units)
Maximum impervious surface85% LMC 16.18.040(C)(3)
50% LMC 16.63.120(E)
for Manufactured home park (4+ units)
Minimum parkingNot read LMC 16.18.050; 16.72.030(C)
The required number of parking spaces is an optional minimum of one space and a maximum of one and one-half spaces per dwelling. LMC 16.62.030(L)(1)
for Cottage housing (4+ units)
Maximum unit sizeNot set LMC 16.18.040
1,200 sq ft LMC 16.62.030(C)
for Cottage housing (4+ units)
250 sq ft LMC 16.56.020(C)
for Co-living housing (group living)
Maximum lot sizeNot set LMC 16.18.040
871,200 sq ft LMC 16.63.110
for Manufactured home park (4+ units)
Maximum building footprintNot set LMC 16.18.040
800 sq ft LMC 16.62.030(C)
for Cottage housing (4+ units)
Minimum open space
  • 10%4 LMC 16.18.040(C)(1)
  • Not set5 LMC 16.18.040(C)(1)
10% LMC 16.63.140
for Manufactured home park (4+ units)
Maximum units per buildingNot set LMC 16.18.040
6 units LMC 16.61.030(I)
for Townhouse (2, 3, 4+ units)

4. ADU standards

Lot

StandardValueExceptions
Maximum unitsthe largest of 0, 3 − main dwelling units on the lot units LMC 16.52.020(A); 16.52.020(B)
the largest of 0, 4 − main dwelling units on the lot units LMC 16.52.020(A); 16.52.020(B)
for Single-family detached structures (1 unit)2; Manufactured Home, Designated (1 unit)2; Duplex (2 units)2; Triplex (3 units)2; Any residential use (4+ units)2; Manufactured home park (4+ units)2; Housing for people with functional disabilities (group living)2; Co-living housing (group living)2; Nursing homes, convalescent care facilities (group living)2
the largest of 0, 6 − main dwelling units on the lot units LMC 16.52.020(A); 16.52.020(B)
for Single-family detached structures (1 unit)3; Manufactured Home, Designated (1 unit)3; Duplex (2 units)3; Triplex (3 units)3; Any residential use (4+ units)3; Manufactured home park (4+ units)3; Housing for people with functional disabilities (group living)3; Co-living housing (group living)3; Nursing homes, convalescent care facilities (group living)3

Building

StandardValueExceptions
Front setback16 ft LMC 16.52.040(A)(1); 16.18.040(A)(3)
Side setback5 ft LMC 16.52.040(A)(1); 16.18.040(A)(4)
Rear setback
  • 0 ft19 LMC 16.52.060(D)
  • 15 ft20 LMC 16.52.040(A)(1); 16.18.040(A)(6)
Maximum height80 ft LMC 16.52.040(A)(1); 16.18.040(C)(4)
Minimum parkingNot read LMC 16.52.040(D)
Maximum unit size1,000 sq ft LMC 16.52.060(B)
Attached to the main houseNot required LMC 16.52.060(A)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision LMC 15.08.090(B); 11.02.290 A 2 to 9 LMC 15.08.010; LMC 15.02.020(TT); 15.08.010 —
Minimum lot size
  • 2,000 sq ft4 LMC 16.18.040(A)(1)
  • 3,500 sq ft5 LMC 16.18.040(A)(1)
Minimum lot width
  • 30 ft4 LMC 16.18.040(A)(2)
  • 40 ft5 LMC 16.18.040(A)(2)
Subdivision LMC 15.10.020; 11.04.050 H 10 or more LMC 15.02.020(UU) —
Minimum lot size
  • 2,000 sq ft4 LMC 16.18.040(A)(1)
  • 3,500 sq ft5 LMC 16.18.040(A)(1)
Minimum lot width
  • 30 ft4 LMC 16.18.040(A)(2)
  • 40 ft5 LMC 16.18.040(A)(2)
Planned residential developments LMC 11.10.140; 11.10.030(C); 16.18.020(A)(1); 11.10.010(C) H —
Minimum parent area
  • The minimum site for a planned residential development shall be a full block or a portion of a block if it was a numbered block in the original plat of the city, or a numbered block of a subdivision recorded prior to the adoption of the ordinance codified in this title.21 LMC 11.10.060
  • 87,120 sq ft22 LMC 11.10.060
Minimum density
12 units per acre LMC 11.10.120(B)(2); 16.18.020(A)(1)
Area taken out for roads and utilities
20% LMC 11.10.120(B)(1)
Minimum lot size
No limit LMC 11.10.080

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Which units on the lot meet the affordability requirements of LMC 16.52.030: none, the fourth unit, or all units is none
  2. Which units on the lot meet the affordability requirements of LMC 16.52.030: none, the fourth unit, or all units is fourth_unit
  3. Which units on the lot meet the affordability requirements of LMC 16.52.030: none, the fourth unit, or all units is all_units
  4. Alleys are utilized for access to the lot
  5. None of these is true:
    • Alleys are utilized for access to the lot
  6. The lot is an infill lot: a lot created from an underdeveloped lot or parcel
  7. All of these are true:
    • Alleys are utilized for access to the lot
    None of these is true:
    • The lot is an infill lot: a lot created from an underdeveloped lot or parcel
  8. None of these is true:
    • The lot is an infill lot: a lot created from an underdeveloped lot or parcel
    • Alleys are utilized for access to the lot
  9. None of these is true:
    • The lot is an infill lot: a lot created from an underdeveloped lot or parcel
  10. All of these are true:
    • The lot is an infill lot: a lot created from an underdeveloped lot or parcel
    • Alleys are utilized for access to the lot
  11. All of these are true:
    • The lot is an infill lot: a lot created from an underdeveloped lot or parcel
    None of these is true:
    • Alleys are utilized for access to the lot
  12. Which kind of housing for people with functional disabilities: adult family home, residential care facility, or other (e.g. supported living arrangement) is adult_family_home
  13. Which kind of housing for people with functional disabilities: adult family home, residential care facility, or other (e.g. supported living arrangement) is residential_care_facility
  14. Which kind of housing for people with functional disabilities: adult family home, residential care facility, or other (e.g. supported living arrangement) is other
  15. The manufactured home space has rear load access
  16. None of these is true:
    • The manufactured home space has rear load access
  17. The cottage has a minimum roof slope of six feet vertical to twelve feet horizontal
  18. None of these is true:
    • The cottage has a minimum roof slope of six feet vertical to twelve feet horizontal
  19. All of these are true:
    • The accessory dwelling unit is detached in a separate structure
    • A lot line abuts a public alley that the public works department has not identified as part of the city's routine snow plow network
  20. Not all of these are true:
    • The accessory dwelling unit is detached in a separate structure
    • A lot line abuts a public alley that the public works department has not identified as part of the city's routine snow plow network
  21. The site is a numbered block of the original plat of the city or of a subdivision recorded before this title was adopted
  22. None of these is true:
    • The site is a numbered block of the original plat of the city or of a subdivision recorded before this title was adopted