RD · Residential
La Conner, WA · LCMC 15.20 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-household dwelling | Home✓ ADU✓ | — | — | — | — |
| Factory-built/manufactured home | Home✓ ADU✓ | — | — | — | — |
| Tiny home | Home✓ ADU✓ | — | — | — | — |
| Townhouse | Home✓ ADU✓ | HomeA ADU— | HomeA ADU— | HomeA ADU— | — |
| Duplex dwelling | — | Home✓ ADU— | — | — | |
| Multi-single-household detached residences | — | HomeA ADU— | HomeA ADU— | HomeA ADU— | — |
| Multihousehold dwelling | — | — | Home✓ ADU— | — | |
| Retirement apartments for senior citizens | — | — | HomeA ADU— | HomeA ADU— | — |
| Planned unit residential developments | — | — | — | — | |
| Adult family homes | — | — | — | — | Home✓ ADU— |
| Supported living arrangements | — | — | — | — | Home✓ ADU— |
| Rooming houses, boardinghouses | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
| Rest/convalescent/nursing homes | — | — | — | — | HomeH ADU— |
| Community residential facilities | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set LCMC 15.20.090 | No limit LCMC 15.20.030(3)
for Multihousehold dwelling (4+ units)2 |
| Minimum lot size | 4,000 + (2,000 × (the largest of main dwelling units on the lot − 2, 0)) sq ft LCMC 15.20.090(1) | 4,000 sq ft LCMC 15.20.060(1)
for Single-household dwelling (1 unit); Factory-built/manufactured home (1 unit); Adult family homes (group living); Supported living arrangements (group living); Rooming houses, boardinghouses (group living); Transitional housing (group living); Permanent supportive housing (group living); Rest/convalescent/nursing homes (group living); Community residential facilities (group living) No limit LCMC 15.20.100(1)
for Tiny home (1 unit) Not set LCMC 15.25
for Planned unit residential developments (4+ units)3 |
| Minimum lot width | 100 ft LCMC 15.20.090(2) | Not set LCMC 15.20.060
for Single-household dwelling (1 unit); Factory-built/manufactured home (1 unit); Tiny home (1 unit); Adult family homes (group living); Supported living arrangements (group living); Rooming houses, boardinghouses (group living); Transitional housing (group living); Permanent supportive housing (group living); Rest/convalescent/nursing homes (group living); Community residential facilities (group living) |
| Maximum density | Not set LCMC 15.20.060 | No limit LCMC 15.20.100(1)
for Tiny home (1 unit) |
| Minimum development size | Not set LCMC 15.20.060 | 16,000 sq ft LCMC 15.25.020
for Planned unit residential developments (4+ units)3 |
| Maximum residents | Not set LCMC 15.20.060 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft LCMC 15.20.090(6) | 11 ft LCMC 15.20.060(4)
for Single-household dwelling (1 unit); Factory-built/manufactured home (1 unit); Tiny home (1 unit); Adult family homes (group living); Supported living arrangements (group living); Rooming houses, boardinghouses (group living); Transitional housing (group living); Permanent supportive housing (group living); Community residential facilities (group living) 25 ft LCMC 15.20.050(3)
for Rest/convalescent/nursing homes (group living) |
| Side setback | 10 ft LCMC 15.20.090(6) | 5 ft LCMC 15.20.060(4)
for Single-household dwelling (1 unit); Factory-built/manufactured home (1 unit); Tiny home (1 unit); Adult family homes (group living); Supported living arrangements (group living); Rooming houses, boardinghouses (group living); Transitional housing (group living); Permanent supportive housing (group living); Community residential facilities (group living) 25 ft LCMC 15.20.050(3)
for Rest/convalescent/nursing homes (group living) |
| Total side setbacks | 20 ft LCMC 15.20.090(6) | Not set LCMC 15.20.060
for Single-household dwelling (1 unit); Factory-built/manufactured home (1 unit); Tiny home (1 unit); Adult family homes (group living); Supported living arrangements (group living); Rooming houses, boardinghouses (group living); Transitional housing (group living); Permanent supportive housing (group living); Rest/convalescent/nursing homes (group living); Community residential facilities (group living) |
| Street side setback | 20 ft LCMC 15.20.090(6) | 11 ft LCMC 15.20.060(4); 15.20.060(5)
for Single-household dwelling (1 unit); Factory-built/manufactured home (1 unit); Tiny home (1 unit); Adult family homes (group living); Supported living arrangements (group living); Rooming houses, boardinghouses (group living); Transitional housing (group living); Permanent supportive housing (group living); Community residential facilities (group living) 25 ft LCMC 15.20.050(3)
for Rest/convalescent/nursing homes (group living) |
| Rear setback | 25 ft LCMC 15.20.090(6) | for Single-household dwelling (1 unit); Factory-built/manufactured home (1 unit); Tiny home (1 unit); Adult family homes (group living); Supported living arrangements (group living); Rooming houses, boardinghouses (group living); Transitional housing (group living); Permanent supportive housing (group living); Community residential facilities (group living) |
| Building separation | Not set LCMC 15.20.060 | 10 ft LCMC 15.25.140(3)
for Planned unit residential developments (4+ units)3 |
| Maximum height | 30 ft LCMC 15.20.060(2) | |
| Maximum stories | 2 stories LCMC 15.20.060(2) | |
| Maximum lot coverage | 70% LCMC 15.20.090(3) | 60% LCMC 15.20.060(3)
for Single-household dwelling (1 unit); Factory-built/manufactured home (1 unit); Tiny home (1 unit); Adult family homes (group living); Supported living arrangements (group living); Rooming houses, boardinghouses (group living); Transitional housing (group living); Permanent supportive housing (group living); Rest/convalescent/nursing homes (group living); Community residential facilities (group living) |
| Maximum impervious surface | 70% LCMC 15.20.100(1) | 60% LCMC 15.20.060(3)
for Single-household dwelling (1 unit); Factory-built/manufactured home (1 unit); Adult family homes (group living); Supported living arrangements (group living); Rooming houses, boardinghouses (group living); Transitional housing (group living); Permanent supportive housing (group living); Rest/convalescent/nursing homes (group living); Community residential facilities (group living) |
| Minimum parking | 2 spaces per unit LCMC 15.90.030(1)(a) | 1 space per unit LCMC 15.20.100(2)
for Tiny home (1 unit) main dwelling units on the lot + (5 × (main dwelling units on the lot ÷ 60, rounded up)) spaces LCMC 15.90.030(2)(b)
for Retirement apartments for senior citizens (3, 4+ units) Not set LCMC 15.20.060
for Adult family homes (group living); Supported living arrangements (group living); Transitional housing (group living); Permanent supportive housing (group living); Community residential facilities (group living) sleeping units in the project + 1 spaces LCMC 15.90.030(3)(c)(iv)
for Rooming houses, boardinghouses (group living) (beds in the project ÷ 3) + employees on the largest shift spaces LCMC 15.90.030(2)(a)
for Rest/convalescent/nursing homes (group living) |
| Maximum unit size | Not set LCMC 15.20.060 | 400 sq ft LCMC 15.10.1197; 15.20.100
for Tiny home (1 unit) |
| Minimum open space | Not set LCMC 15.20.060 | 50% LCMC 15.25.120(5)
for Planned unit residential developments (4+ units)3 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units LCMC 15.110.080(2) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 11 ft LCMC 15.110.080(7); 15.20.060(4) | |
| Side setback | 5 ft LCMC 15.110.080(7); 15.20.060(4) | |
| Rear setback | ||
| Maximum height | 30 ft LCMC 15.110.080(7); 15.20.060(2) | |
| Maximum stories | 2 stories LCMC 15.110.080(7); 15.20.060(2) | |
| Minimum parking | 1 space per unit LCMC 15.110.080(8); 15.90.030(1)(d) | |
| Maximum unit size | ||
| Attached to the main house | Not required LCMC 15.110.080(1)(a)-(d) | |
| Owner lives on site | Not required LCMC 15.110.080(3) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Lot line adjustment LCMC 15.125.050(1)-(2); 15.135.050(1) | A | Maximum lots which does not create any additional lot, tract, parcel, site, or division LCMC 15.10.645 |
— | Minimum lot size no lot conforming to the minimum lot size requirement of the district is reduced below that minimum lot size LCMC 15.125.050(1) |
| Short subdivision LCMC 15.135.050(1) | A | up to 4 LCMC 15.10.1170 | — | Minimum lot size 4,000 sq ft LCMC 15.20.060(1) |
| Subdivision LCMC 15.135.050(1) | H | 5 or more LCMC 15.10.1165 | — | Minimum lot size 4,000 sq ft LCMC 15.20.060(1) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Project puts more than one multihousehold dwelling, duplex or townhome on the lot
- None of these is true:
- Project puts more than one multihousehold dwelling, duplex or townhome on the lot
- None of these is true:
- Lot is in the Historic Preservation District
- None of these is true:
- PURD is designed to house low, very low or extremely low-income families or individuals
- PURD is designed to house low, very low or extremely low-income families or individuals
- None of these is true:
- DSHS determines the home is of adequate size for up to eight adults
- DSHS determines the home is of adequate size for up to eight adults
- None of these is true:
- Alley access is available to the lot
- Alley access is available to the lot
- Bedrooms in one unit is at most 1
- Bedrooms in one unit is more than 1
- Lot area is less than 5,000 sf
- Lot area is at least 5,000 sf