Sign in

HDR · High Density Residential (HDR)

La Center, WA · LCMC 18.142 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family attached dwelling units
Home✓ ADUA
————
Multifamily dwellings—
Home✓ ADU—
Home✓ ADU—
Home✓ ADU—
—
Cottage housing———
HomeH ADU—
—
Foster care homes————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set LCMC 18.142.040
12 units LCMC 18.185.040(1)
for Cottage housing (4+ units)
Minimum unitsNot set LCMC 18.142.040
4 units LCMC 18.185.040(1)
for Cottage housing (4+ units)
Minimum lot size1,500 sq ft LCMC 18.142.040(1), Table 18.142.040
2,000 sq ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)
Minimum lot width20 ft LCMC 18.142.040(1), Table 18.142.040
Not set LCMC 18.185.040
for Cottage housing (4+ units)
Minimum lot depth60 ft LCMC 18.142.040(1), Table 18.142.040
Not set LCMC 18.185.040
for Cottage housing (4+ units)
Minimum density16 units per acre LCMC 18.142.040(1), Table 18.142.040
Not set LCMC 18.142.040(1), Table 18.142.040
for Foster care homes (group living)
Maximum density24 units per acre, on the net lot area LCMC 18.142.040(1), Table 18.142.040
Not set LCMC 18.142.040(1), Table 18.142.040
for Foster care homes (group living)
Maximum residents5 persons LCMC 18.40.010

3. Building standards

StandardValueExceptions
Front setback
  • 20 ft1 LCMC 18.142.040(1), Table 18.142.040 note 4
  • 15 ft2 LCMC 18.142.040(1), Table 18.142.040 note 4
  • 10 ft3 LCMC 18.142.040(1), Table 18.142.040
10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)
Side setback
  • 10 ft4 LCMC 18.142.040(1), Table 18.142.040
  • 0 ft5 LCMC 18.142.040(1), Table 18.142.040
10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)
Street side setback0 ft LCMC 18.142.040(1), Table 18.142.040
10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)
Rear setback20 ft LCMC 18.142.040(1), Table 18.142.040
10 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)
Building separationNot set LCMC 18.142.040
10 ft LCMC 18.185.040(3), Table 18.185.040 note 2
for Cottage housing (4+ units)
Maximum height45 ft LCMC 18.142.040(1), Table 18.142.040
25 ft LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)
Maximum storiesNot set LCMC 18.142.040
2 stories LCMC 18.185.060(1)
for Cottage housing (4+ units)
Maximum lot coverage85% LCMC 18.142.040(1), Table 18.142.040
45% LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)
Maximum impervious surfaceNot set LCMC 18.142.040
60% LCMC 18.185.040(3), Table 18.185.040
for Cottage housing (4+ units)
Minimum parking(2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 5), rounded up spaces LCMC 18.280.040(1)-(2)
3 spaces per unit LCMC 18.280.040(1); 18.185.130(1)(h)
for Cottage housing (4+ units)
For uses not listed in Table 18.280.040, the review authority shall determine the required number of parking spaces by selecting the use with the most similar parking demand requirements. LCMC 18.280.040(3)
for Foster care homes (group living)
Maximum unit sizeNot set LCMC 18.142.040
1.5 × 1,000 sq ft LCMC 18.185.060(1)(a)-(b)
for Cottage housing (4+ units)
Maximum building footprintNot set LCMC 18.142.040
1,000 sq ft LCMC 18.185.060(1)(a)
for Cottage housing (4+ units)
Minimum open space15% LCMC 18.142.040(2); 18.140.040(3)(c)
Maximum units per buildingNot set LCMC 18.142.040
6 units LCMC 18.142.040(2)(a); 18.140.050(3)
for Single-family attached dwelling units (1 unit)

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit LCMC 18.247.050(2)
Minimum lot size
  • 5,000 sq ft6 LCMC 18.247.050(1)
  • Not set7 LCMC 18.247.050(1)

Building

StandardValueExceptions
Front setback
  • 20 ft1 LCMC 18.247.050(4)(a); LCMC 18.142.040(1), Table 18.142.040 note 4
  • 15 ft2 LCMC 18.247.050(4)(a); LCMC 18.142.040(1), Table 18.142.040 note 4
  • 10 ft3 LCMC 18.247.050(4)(a); LCMC 18.142.040(1), Table 18.142.040
Side setback
  • 10 ft8 LCMC 18.247.050(4)(b)
  • 5 ft9 LCMC 18.247.050(4)(b)
Rear setback
  • 0 ft10 LCMC 18.247.050(4)(c)
  • 5 ft11 LCMC 18.247.050(4)(b)
Maximum height
  • 25 ft6 LCMC 18.247.050(5)(a)
  • 45 ft7 LCMC 18.247.050(5)(b); LCMC 18.142.040(1), Table 18.142.040
Minimum parking1 space per unit LCMC 18.247.050(7)
Maximum unit size
  • the smallest of 900, 0.4 × floor area of the main house sq ft12 LCMC 18.247.050(3)(b)
  • The gross floor area shall not exceed 900 square feet or 40 percent of the primary single-family structure, not including the garage and/or detached accessory buildings, whichever is less. Internal ADUs may exceed 900 square feet provided they are not larger than the size of the remainder of the single-family dwelling.13 LCMC 18.247.050(3)(b)
Attached to the main houseNot required LCMC 18.247.040(1)(c)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision LCMC 18.205.020(2) A up to 4 LCMC 18.40.010 —
Minimum lot size
1,500 sq ft LCMC 18.142.040(1), Table 18.142.040
Minimum lot width
20 ft LCMC 18.142.040(1), Table 18.142.040
Minimum lot depth
60 ft LCMC 18.142.040(1), Table 18.142.040
Subdivision LCMC 18.210.020(2) H 5 or more LCMC 18.40.010 —
Minimum lot size
1,500 sq ft LCMC 18.142.040(1), Table 18.142.040
Minimum lot width
20 ft LCMC 18.142.040(1), Table 18.142.040
Minimum lot depth
60 ft LCMC 18.142.040(1), Table 18.142.040

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The lot fronts an arterial street
  2. All of these are true:
    • The lot fronts a collector street
    None of these is true:
    • The lot fronts an arterial street
  3. None of these is true:
    • The lot fronts an arterial street
    • The lot fronts a collector street
  4. The side lot line abuts single-family detached development
  5. None of these is true:
    • The side lot line abuts single-family detached development
  6. Whether the ADU is internal to the single-family dwelling, an addition to it, or a detached structure is detached
  7. Whether the ADU is internal to the single-family dwelling, an addition to it, or a detached structure is not detached
  8. The ADU side lot line is a street side lot line
  9. None of these is true:
    • The ADU side lot line is a street side lot line
  10. All of these are true:
    • Whether the ADU is internal to the single-family dwelling, an addition to it, or a detached structure is detached
    • The rear yard of the lot is adjacent to an alley
  11. Not all of these are true:
    • Whether the ADU is internal to the single-family dwelling, an addition to it, or a detached structure is detached
    • The rear yard of the lot is adjacent to an alley
  12. Whether the ADU is internal to the single-family dwelling, an addition to it, or a detached structure is not internal
  13. Whether the ADU is internal to the single-family dwelling, an addition to it, or a detached structure is internal