UR · Urban Restricted
Kitsap County, WA · KCC 17.180 · Official code
By right: 1 unit, 2 units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family detached (includes manufactured homes) | Home✓ ADU✓ | — | — | — | — |
| Duplex | — | Home✓ ADU✓ | — | — | — |
| Single-family attached | — | — | |||
| Cottage housing development | — | HomeA ADU— | HomeA ADU— | HomeA ADU— | — |
| Multiple-family | — | — | — | ||
| Manufactured/mobile/RV/park model/tiny home park | — | — | — | HomeA ADU— | — |
| Adult family home | — | — | — | — | Home✓ ADU✓ |
| Group living | — | — | — | — | |
| Permanent transitory accommodations, small, large, safe parks, and indoor | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 5,800 sq ft KCC 17.420.052; 17.420.060(A)(63) | 1,200 sq ft KCC 17.420.052; 17.420.060(A)(63)
for Single-family attached (2, 3, 4+ units)1 |
| Minimum lot width | 60 ft KCC 17.420.052; 17.420.060(A)(63) | 20 ft KCC 17.420.052; 17.420.060(A)(63)
for Single-family attached (2, 3, 4+ units)1 |
| Minimum lot depth | 60 ft KCC 17.420.052; 17.420.060(A)(63) | |
| Minimum density | 1 units per acre KCC 17.420.052; 17.420.060(A)(18) | Not set KCC 17.420.052
for Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living) Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
|
| Maximum density | Not set KCC 17.420.052
for Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living) Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
| |
| Maximum residents | Not set KCC 17.415.250 | “Adult family home” means a dwelling licensed pursuant to Chapter 70.128 RCW in which a person or persons provide personal care, special care, and room and board to a number of persons consistent with the state definition. KCC 17.110.045
for Adult family home (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
for Single-family detached (includes manufactured homes) (1 unit); Single-family attached (2, 3, 4+ units)1 |
| Maximum front setback | No limit KCC 17.420.052; 17.420.040 | |
| Side setback | 5 ft KCC 17.420.052; 17.420.060(A)(29) | for Single-family detached (includes manufactured homes) (1 unit) |
| Rear setback | ||
| Building separation | Not set KCC 17.420.052 | 10 ft KCC 17.415.135(B)
for Cottage housing development (2, 3, 4+ units) |
| Maximum height | 24 ft KCC 17.415.135(C)
for Cottage housing development (2, 3, 4+ units) | |
| Maximum lot coverage | 50% KCC 17.415.135(A)
for Cottage housing development (2, 3, 4+ units) | |
| Maximum impervious surface | ||
| Minimum parking | 2 spaces per unit KCC 17.490.030 | Other uses not specifically listed above shall furnish parking as required by the director. The director shall use the above list as a guide for determining requirements for said other uses. KCC 17.490.030(B)(1)
|
| Maximum unit size | Not set KCC 17.420.052 | 1,200 sq ft KCC 17.415.135(D)
for Cottage housing development (2, 3, 4+ units) |
| Maximum lot size | No limit KCC 17.420.052; 17.420.040 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units KCC 17.415.010(A) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Side setback | 5 ft KCC 17.420.052; 17.420.060(A)(29) | |
| Rear setback | ||
| Maximum height | ||
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft KCC 17.415.010(G) | |
| Attached to the main house | Not required KCC 17.410.042 |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision KCC 16.48.020 | A | up to 9 KCC 16.10.320(A) | — | Minimum lot size 5,800 sq ft KCC 17.420.052; 17.420.060(A)(63) Minimum lot width 60 ft KCC 17.420.052; 17.420.060(A)(63) Minimum lot depth 60 ft KCC 17.420.052; 17.420.060(A)(63) |
| Subdivision KCC 16.40.030 | H | 10 or more KCC 16.10.340 | — | Minimum lot size 5,800 sq ft KCC 17.420.052; 17.420.060(A)(63) Minimum lot width 60 ft KCC 17.420.052; 17.420.060(A)(63) Minimum lot depth 60 ft KCC 17.420.052; 17.420.060(A)(63) |
| Binding site plan KCC 16.56.040 | A32 | Minimum lots Not set KCC 16.56 |
— | Minimum lot size 5,800 sq ft KCC 17.420.052; 17.420.060(A)(63); 16.56.030(A) Minimum lot width 60 ft KCC 17.420.052; 17.420.060(A)(63); 16.56.030(A) Minimum lot depth 60 ft KCC 17.420.052; 17.420.060(A)(63); 16.56.030(A) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- Lot is in the part of the Gorst urban growth area between the Sinclair Inlet shoreline and State Highways 3 and 16
- None of these is true:
- Lot is in the Gorst urban growth area
- All of these are true:
- Sleeping units in the project is at most 6
- Lot is in the part of the Gorst urban growth area between the Sinclair Inlet shoreline and State Highways 3 and 16
- All of these are true:
- Sleeping units in the project is more than 6
- Lot is in the part of the Gorst urban growth area between the Sinclair Inlet shoreline and State Highways 3 and 16
- All of these are true:
- Lot is in the Gorst urban growth area
- Project earns Gorst incentive bonuses for public benefits (Table 17.400.080(C))
- Not all of these are true:
- Lot is in the Gorst urban growth area
- Project earns Gorst incentive bonuses for public benefits (Table 17.400.080(C))
- Type of transitory accommodation is small
- Type of transitory accommodation is large
- Type of transitory accommodation is safe_park
- Type of transitory accommodation is indoor
- One or both abutting lots have dwellings with front yards less than the required depth
- All of these are true:
- Lot is in the Gorst urban growth area
- One or both abutting lots have dwellings with front yards less than the required depth
- None of these is true:
- One or both abutting lots have dwellings with front yards less than the required depth
- Lot is in the Gorst urban growth area
- Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
- All of these are true:
- One or both abutting lots have dwellings with front yards less than the required depth
- Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
- All of these are true:
- Lot is in the Gorst urban growth area
- Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
- One or both abutting lots have dwellings with front yards less than the required depth
- None of these is true:
- Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
- One or both abutting lots have dwellings with front yards less than the required depth
- Lot is in the Gorst urban growth area
- Lot is in the Gorst urban growth area
- None of these is true:
- Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
- All of these are true:
- Lot is in the Gorst urban growth area
- Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
- None of these is true:
- Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
- Lot is in the Gorst urban growth area
- Lot is in the Illahee View Protection Overlay (Appendix B1)
- None of these is true:
- Lot is in the Illahee View Protection Overlay (Appendix B1)
- All of these are true:
- Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
- The housing unit is affordable to very low-income or extremely low-income individuals
- All of these are true:
- Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
- Bedrooms in one unit is at most 0
- The housing unit is affordable to very low-income or extremely low-income individuals
- All of these are true:
- Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
- Bedrooms in one unit is 1
- The housing unit is affordable to very low-income or extremely low-income individuals
- All of these are true:
- Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
- Bedrooms in one unit is at least 2
- The housing unit is affordable to very low-income or extremely low-income individuals
- All of these are true:
- Bedrooms in one unit is at most 1
- Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
- All of these are true:
- Bedrooms in one unit is at least 2
- Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
- Any of these is true:
- The primary dwelling unit meets all parking requirements
- On-street parking is available
- The ADU is within one-half mile of a major transit stop as defined in RCW 36.70A.696(8)
- None of these is true:
- The primary dwelling unit meets all parking requirements
- On-street parking is available
- The ADU is within one-half mile of a major transit stop as defined in RCW 36.70A.696(8)
- The land is divided through a condominium process under Chapter 64.32 or 64.34 RCW