SVLR · Suquamish Village Low Residential
Kitsap County, WA · KCC 17.360D · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family detached (includes manufactured homes) | — | — | — | — | |
| Duplex | — | — | — | — | |
| Single-family attached | — | — | |||
| Cottage housing development | — | HomeA ADU— | HomeA ADU— | HomeA ADU— | — |
| Adult family home | — | — | — | — | |
| Group living | — | — | — | — | |
| Permanent transitory accommodations, small, large, safe parks, and indoor | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 4,500 sq ft KCC 17.420.056; 17.420.060(A)(4); 17.420.060(A)(11) | |
| Minimum lot width | 50 ft KCC 17.420.056; 17.420.060(A)(4); 17.420.060(A)(11) | |
| Minimum lot depth | 90 ft KCC 17.420.056; 17.420.060(A)(4); 17.420.060(A)(11) | |
| Minimum density | No limit KCC 17.420.056; 17.420.040 | Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
for Group living (group living)3 |
| Maximum density | 2 units per acre, a fraction of 0.5 or more rounds up KCC 17.420.056; 17.420.020(A) | Not set KCC 17.420.056
for Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living) Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
for Group living (group living)3 |
| Maximum residents | “Adult family home” means a dwelling licensed pursuant to Chapter 70.128 RCW in which a person or persons provide personal care, special care, and room and board to a number of persons consistent with the state definition. KCC 17.110.045 | Not set KCC 17.415.250
for Group living (group living)3 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
20 ft KCC 17.420.056; 17.420.060(A)(11)
for Group living (group living)3; Permanent transitory accommodations, small, large, safe parks, and indoor (group living) |
| Maximum front setback | No limit KCC 17.420.056; 17.420.040 | |
| Side setback | 5 ft KCC 17.420.056; 17.420.060(A)(11) | |
| Rear setback | ||
| Building separation | Not set KCC 17.420.056 | 10 ft KCC 17.415.135(B)
for Cottage housing development (2, 3, 4+ units) |
| Maximum height | 30 ft KCC 17.420.056 | 24 ft KCC 17.415.135(C)
for Cottage housing development (2, 3, 4+ units) |
| Maximum stories | 2 stories KCC 17.420.056 | |
| Maximum lot coverage | No limit KCC 17.420.056; 17.420.040 | 50% KCC 17.415.135(A)
for Cottage housing development (2, 3, 4+ units) |
| Maximum impervious surface | 40% KCC 17.420.056; 17.420.060(A)(6) | |
| Minimum parking | 2 spaces per unit KCC 17.490.030 | for Cottage housing development (2, 3, 4+ units) Other uses not specifically listed above shall furnish parking as required by the director. The director shall use the above list as a guide for determining requirements for said other uses. KCC 17.490.030(B)(1)
for Adult family home (group living); Group living (group living)3; Permanent transitory accommodations, small, large, safe parks, and indoor (group living) |
| Maximum unit size | Not set KCC 17.420.056 | 1,200 sq ft KCC 17.415.135(D)
for Cottage housing development (2, 3, 4+ units) |
| Maximum lot size | No limit KCC 17.420.056; 17.420.040 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit KCC 17.415.015(A)(4); 17.415.015(A)(6) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Side setback | 5 ft KCC 17.420.056; 17.420.060(A)(11) | |
| Rear setback | ||
| Maximum height | 30 ft KCC 17.420.056 | |
| Maximum stories | 2 stories KCC 17.420.056 | |
| Minimum parking | 1 space per unit KCC 17.415.015(A)(5); 17.490.030 | |
| Maximum unit size | 0.5 × floor area of the main house sq ft KCC 17.415.015(A)(2) | |
| Attached to the main house | Required KCC 17.415.015(A)(1); 17.110.017 | |
| Owner lives on site | Required KCC 17.415.015(A)(1) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision KCC 16.48.020 | A | up to 4 KCC 16.10.320(B) | — | Minimum lot size 21,780 sq ft KCC 17.420.060(A)(11)(a)(i) Minimum lot width 100 ft KCC 17.420.060(A)(11)(a)(ii) Minimum lot depth 100 ft KCC 17.420.060(A)(11)(a)(iii) |
| Binding site plan KCC 16.56.040 | A14 | Minimum lots Not set KCC 16.56 |
— | Minimum lot size 4,500 sq ft KCC 17.420.056; 17.420.060(A)(4); 17.420.060(A)(11); 16.56.030(A) Minimum lot width 50 ft KCC 17.420.056; 17.420.060(A)(4); 17.420.060(A)(11); 16.56.030(A) Minimum lot depth 90 ft KCC 17.420.056; 17.420.060(A)(4); 17.420.060(A)(11); 16.56.030(A) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The ADU is detached (not within or connected by at least 4 ft to the habitable space of the primary residence)
- The ADU is detached (not within or connected by at least 4 ft to the habitable space of the primary residence)
- Sleeping units in the project is at most 6
- Type of transitory accommodation is small
- Type of transitory accommodation is large
- Type of transitory accommodation is safe_park
- Type of transitory accommodation is indoor
- One or both abutting lots have dwellings with front yards less than the required depth
- None of these is true:
- One or both abutting lots have dwellings with front yards less than the required depth
- Lot abuts a residential zone (larger setback on the abutting yard)
- None of these is true:
- Lot abuts a residential zone (larger setback on the abutting yard)
- Bedrooms in one unit is at most 1
- Bedrooms in one unit is at least 2
- The land is divided through a condominium process under Chapter 64.32 or 64.34 RCW