Sign in

NC · Neighborhood Commercial

Kitsap County, WA · KCC 17.270 · Official code

By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family detached (includes manufactured homes)
Home✓ ADU✓1 ✓2 ✓3
————
Duplex—
Home✓ ADU✓1 ✓2 ✓3
———
Single-family attached—
Home✓ ADU✓1 ✓2 ✓3
Home✓ ADU✓1 ✓2 ✓3
Home✓ ADU✓1 ✓2 ✓3
—
Cottage housing development—
HomeA ADU—
HomeA ADU—
HomeA ADU—
—
Multiple-family——
Home✓ ADU—
Home✓ ADU—
—
Manufactured/mobile/RV/park model/tiny home park———
HomeH ADU—
—
Adult family home————
Home✓ ADU✓1 ✓2 ✓3
Group living————
Home✓4 A5 ADU—
Permanent transitory accommodations, small, large, safe parks, and indoor————
HomeA ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot sizeNo limit KCC 17.420.054; 17.420.040
Minimum lot widthNo limit KCC 17.420.054; 17.420.040
Minimum lot depthNo limit KCC 17.420.054; 17.420.040
Minimum density
  • No limit6 KCC 17.420.054; 17.420.060(A)(57)
  • 10 units per acre7 KCC 17.420.054; 17.420.060(A)(57)
Not set KCC 17.420.054
for Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
for Group living (group living)4; Group living (group living)5
Maximum density30 units per acre, a fraction of 0.5 or more rounds up KCC 17.420.054; 17.420.020(A)
Not set KCC 17.420.054
for Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
for Group living (group living)4; Group living (group living)5
Maximum residentsNot set KCC 17.415.250
“Adult family home” means a dwelling licensed pursuant to Chapter 70.128 RCW in which a person or persons provide personal care, special care, and room and board to a number of persons consistent with the state definition. KCC 17.110.045
for Adult family home (group living)
  • 25 persons8 KCC 17.505.040(B)
  • 50 persons9 KCC 17.505.040(C)
  • 25 persons10 KCC 17.505.040(D)
  • 75 persons11 KCC 17.505.040(E)
for Permanent transitory accommodations, small, large, safe parks, and indoor (group living)

3. Building standards

StandardValueExceptions
Front setback
  • a. If there are dwellings on both abutting lots with front yards less than the required depth for the zone, the front yard for the lot need not exceed the average front yard of the abutting dwellings. b. If there is a dwelling on one abutting lot with a front yard less than the required depth for the zone, the front yard need not exceed a depth of halfway between the depth of the front yard on the abutting lot and the required front yard depth.12 KCC 17.420.060(A)(41)
  • 20 ft13 KCC 17.420.054; 17.420.060(A)(29)
  • 100 ft14 KCC 17.420.060(A)(29)
  • a. If there are dwellings on both abutting lots with front yards less than the required depth for the zone, the front yard for the lot need not exceed the average front yard of the abutting dwellings. b. If there is a dwelling on one abutting lot with a front yard less than the required depth for the zone, the front yard need not exceed a depth of halfway between the depth of the front yard on the abutting lot and the required front yard depth.15 KCC 17.420.060(A)(41)
  • 20 ft16 KCC 17.420.054; 17.420.060(A)(29)
for Single-family detached (includes manufactured homes) (1 unit); Single-family attached (2, 3, 4+ units)
20 ft KCC 17.420.054; 17.420.060(A)(29)
for Group living (group living)4; Group living (group living)5; Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Maximum front setbackNo limit KCC 17.420.054; 17.420.040
Side setback
  • 20 ft17 KCC 17.420.054; 17.420.060(A)(21)
  • 10 ft18 KCC 17.420.054; 17.420.060(A)(29)
  • 100 ft14 KCC 17.420.060(A)(29)
  • 20 ft19 KCC 17.420.054; 17.420.060(A)(21)
  • 10 ft20 KCC 17.420.054; 17.420.060(A)(29)
for Single-family detached (includes manufactured homes) (1 unit); Single-family attached (2, 3, 4+ units)
Rear setback
  • 20 ft17 KCC 17.420.054; 17.420.060(A)(21)
  • 10 ft18 KCC 17.420.054; 17.420.060(A)(29)
  • 100 ft14 KCC 17.420.060(A)(29)
  • 20 ft19 KCC 17.420.054; 17.420.060(A)(21)
  • 10 ft20 KCC 17.420.054; 17.420.060(A)(29)
for Single-family detached (includes manufactured homes) (1 unit); Single-family attached (2, 3, 4+ units)
Building separationNot set KCC 17.420.054
10 ft KCC 17.415.135(B)
for Cottage housing development (2, 3, 4+ units)
Maximum height
  • 28 ft21 KCC 17.420.060(A)(50)
  • 35 ft22 KCC 17.420.054
24 ft KCC 17.415.135(C)
for Cottage housing development (2, 3, 4+ units)
  • 28 ft23 KCC 17.420.060(A)(50)
  • 28 ft24 KCC 17.420.060(A)(50)
  • 45 ft25 KCC 17.420.054; 17.420.060(A)(17); 17.420.035
  • 35 ft26 KCC 17.420.054
for Multiple-family (3, 4+ units)
Maximum lot coverageNo limit KCC 17.420.054; 17.420.040
50% KCC 17.415.135(A)
for Cottage housing development (2, 3, 4+ units)
Maximum impervious surface85% KCC 17.420.054
Minimum parking2 spaces per unit KCC 17.490.030
  • 0.75 spaces per unit27 KCC 17.490.030
  • 0.75 spaces per unit28 KCC 17.490.030
  • 1 space per unit29 KCC 17.490.030
  • 2 spaces per unit30 KCC 17.490.030
  • 1.5 spaces per unit31 KCC 17.490.030
  • 2 spaces per unit32 KCC 17.490.030
for Cottage housing development (2, 3, 4+ units); Multiple-family (3, 4+ units)
Other uses not specifically listed above shall furnish parking as required by the director. The director shall use the above list as a guide for determining requirements for said other uses. KCC 17.490.030(B)(1)
for Manufactured/mobile/RV/park model/tiny home park (4+ units); Adult family home (group living); Group living (group living)4; Group living (group living)5; Permanent transitory accommodations, small, large, safe parks, and indoor (group living)
Maximum unit sizeNot set KCC 17.420.054
1,200 sq ft KCC 17.415.135(D)
for Cottage housing development (2, 3, 4+ units)
Maximum lot sizeNo limit KCC 17.420.054; 17.420.040

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit KCC 17.415.015(A)(4); 17.415.015(A)(6)
2 units KCC 17.415.010(A)
for Single-family detached (includes manufactured homes) (1 unit)1; Duplex (2 units)1; Single-family attached (2, 3, 4+ units)1; Adult family home (group living)1

Building

StandardValueExceptions
Front setback
  • a. If there are dwellings on both abutting lots with front yards less than the required depth for the zone, the front yard for the lot need not exceed the average front yard of the abutting dwellings. b. If there is a dwelling on one abutting lot with a front yard less than the required depth for the zone, the front yard need not exceed a depth of halfway between the depth of the front yard on the abutting lot and the required front yard depth.12 KCC 17.420.060(A)(41)
  • 20 ft13 KCC 17.420.054; 17.420.060(A)(29)
Side setback
  • 20 ft17 KCC 17.420.054; 17.420.060(A)(21)
  • 10 ft18 KCC 17.420.054; 17.420.060(A)(29)
Rear setback
  • 20 ft17 KCC 17.420.054; 17.420.060(A)(21)
  • 10 ft18 KCC 17.420.054; 17.420.060(A)(29)
Maximum height
  • 28 ft21 KCC 17.420.060(A)(50)
  • 35 ft22 KCC 17.420.054
Minimum parking1 space per unit KCC 17.415.015(A)(5); 17.490.030
  • the largest of ADUs on the lot − 1, 0 spaces33 KCC 17.415.010(H); 17.490.030
  • 1 space per unit34 KCC 17.415.010(H); 17.490.030
for Single-family detached (includes manufactured homes) (1 unit)1; Duplex (2 units)1; Single-family attached (2, 3, 4+ units)1; Adult family home (group living)1
Maximum unit size1,000 sq ft KCC 17.415.010(G)
0.5 × floor area of the main house sq ft KCC 17.415.015(A)(2)
for Single-family detached (includes manufactured homes) (1 unit)2; Duplex (2 units)2; Single-family attached (2, 3, 4+ units)2; Adult family home (group living)2
the smallest of 0.5 × floor area of the main house, 900 sq ft KCC 17.415.015(B)(3)
for Single-family detached (includes manufactured homes) (1 unit)3; Duplex (2 units)3; Single-family attached (2, 3, 4+ units)3; Adult family home (group living)3
Attached to the main houseNot required KCC 17.410.044
Required KCC 17.415.015(A)(1); 17.110.017
for Single-family detached (includes manufactured homes) (1 unit)2; Duplex (2 units)2; Single-family attached (2, 3, 4+ units)2; Adult family home (group living)2
Owner lives on siteRequired KCC 17.415.015(A)(1)
Not set KCC 17.415.010
for Single-family detached (includes manufactured homes) (1 unit)1; Duplex (2 units)1; Single-family attached (2, 3, 4+ units)1; Adult family home (group living)1

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision KCC 16.48.020 A1 up to 9 KCC 16.10.320(A) —
Minimum lot size
No limit KCC 17.420.054; 17.420.040
Minimum lot width
No limit KCC 17.420.054; 17.420.040
Minimum lot depth
No limit KCC 17.420.054; 17.420.040
Subdivision KCC 16.40.030 H1 10 or more KCC 16.10.340 —
Minimum lot size
No limit KCC 17.420.054; 17.420.040
Minimum lot width
No limit KCC 17.420.054; 17.420.040
Minimum lot depth
No limit KCC 17.420.054; 17.420.040
Short subdivision KCC 16.48.020 A35 up to 4 KCC 16.10.320(B) —
Minimum lot size
No limit KCC 17.420.054; 17.420.040
Minimum lot width
No limit KCC 17.420.054; 17.420.040
Minimum lot depth
No limit KCC 17.420.054; 17.420.040
Subdivision KCC 16.40.030 H35 5 or more KCC 16.10.340 —
Minimum lot size
No limit KCC 17.420.054; 17.420.040
Minimum lot width
No limit KCC 17.420.054; 17.420.040
Minimum lot depth
No limit KCC 17.420.054; 17.420.040
Binding site plan KCC 16.56.040 A
Minimum lots
Not set KCC 16.56
—
Minimum lot size
No limit KCC 17.420.054; 17.420.040; 16.56.030(A)
Minimum lot width
No limit KCC 17.420.054; 17.420.040; 16.56.030(A)
Minimum lot depth
No limit KCC 17.420.054; 17.420.040; 16.56.030(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Lot is inside an urban growth area (UGA) boundary
  2. None of these is true:
    • Lot is inside an urban growth area (UGA) boundary
    • The ADU is detached (not within or connected by at least 4 ft to the habitable space of the primary residence)
  3. All of these are true:
    • The ADU is detached (not within or connected by at least 4 ft to the habitable space of the primary residence)
    None of these is true:
    • Lot is inside an urban growth area (UGA) boundary
  4. Sleeping units in the project is at most 6
  5. Sleeping units in the project is more than 6
  6. The project is a mixed use project
  7. None of these is true:
    • The project is a mixed use project
  8. Type of transitory accommodation is small
  9. Type of transitory accommodation is large
  10. Type of transitory accommodation is safe_park
  11. Type of transitory accommodation is indoor
  12. One or both abutting lots have dwellings with front yards less than the required depth
  13. None of these is true:
    • One or both abutting lots have dwellings with front yards less than the required depth
  14. Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
  15. All of these are true:
    • One or both abutting lots have dwellings with front yards less than the required depth
    None of these is true:
    • Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
  16. None of these is true:
    • Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
    • One or both abutting lots have dwellings with front yards less than the required depth
  17. Lot abuts a residential zone (larger setback on the abutting yard)
  18. None of these is true:
    • Lot abuts a residential zone (larger setback on the abutting yard)
  19. All of these are true:
    • Lot abuts a residential zone (larger setback on the abutting yard)
    None of these is true:
    • Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
  20. None of these is true:
    • Lot abuts the FRL or RW zone (100 ft setback for single-family buildings on that side)
    • Lot abuts a residential zone (larger setback on the abutting yard)
  21. Lot is in the Illahee View Protection Overlay (Appendix B1)
  22. None of these is true:
    • Lot is in the Illahee View Protection Overlay (Appendix B1)
  23. All of these are true:
    • Lot is in the Illahee View Protection Overlay (Appendix B1)
    • The project qualifies as mixed use or multifamily development and meets the modification or waiver request criteria of 17.420.035 for height
  24. All of these are true:
    • Lot is in the Illahee View Protection Overlay (Appendix B1)
    None of these is true:
    • The project qualifies as mixed use or multifamily development and meets the modification or waiver request criteria of 17.420.035 for height
  25. All of these are true:
    • The project qualifies as mixed use or multifamily development and meets the modification or waiver request criteria of 17.420.035 for height
    None of these is true:
    • Lot is in the Illahee View Protection Overlay (Appendix B1)
  26. None of these is true:
    • Lot is in the Illahee View Protection Overlay (Appendix B1)
    • The project qualifies as mixed use or multifamily development and meets the modification or waiver request criteria of 17.420.035 for height
  27. All of these are true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
    • The housing unit is affordable to very low-income or extremely low-income individuals
  28. All of these are true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
    • Bedrooms in one unit is at most 0
    None of these is true:
    • The housing unit is affordable to very low-income or extremely low-income individuals
  29. All of these are true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
    • Bedrooms in one unit is 1
    None of these is true:
    • The housing unit is affordable to very low-income or extremely low-income individuals
  30. All of these are true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
    • Bedrooms in one unit is at least 2
    None of these is true:
    • The housing unit is affordable to very low-income or extremely low-income individuals
  31. All of these are true:
    • Bedrooms in one unit is at most 1
    None of these is true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
  32. All of these are true:
    • Bedrooms in one unit is at least 2
    None of these is true:
    • Lot is in a frequent transit service area (within 1/4 mile of a stop with service twice an hour for 12+ hours a day, or 1/2 mile of the Kingston ferry terminals)
  33. Any of these is true:
    • The primary dwelling unit meets all parking requirements
    • On-street parking is available
    • The ADU is within one-half mile of a major transit stop as defined in RCW 36.70A.696(8)
  34. None of these is true:
    • The primary dwelling unit meets all parking requirements
    • On-street parking is available
    • The ADU is within one-half mile of a major transit stop as defined in RCW 36.70A.696(8)
  35. None of these is true:
    • Lot is inside an urban growth area (UGA) boundary