MVR · Manchester Village Residential
Kitsap County, WA · KCC 17.360B · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family detached (includes manufactured homes) | — | — | — | — | |
| Duplex | — | — | — | — | |
| Single-family attached | — | — | |||
| Adult family home | — | — | — | — | |
| Group living | — | — | — | — | |
| Permanent transitory accommodations, small, large, safe parks, and indoor | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 10,890 sq ft KCC 17.420.056; 17.420.060(A)(12) | |
| Minimum lot width | 60 ft KCC 17.420.056; 17.420.060(A)(12) | |
| Minimum lot depth | 60 ft KCC 17.420.056; 17.420.060(A)(12) | |
| Minimum density | No limit KCC 17.420.056; 17.420.040 | Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
for Group living (group living)3 |
| Maximum density | 4 units per acre, a fraction of 0.5 or more rounds up KCC 17.420.056; 17.420.060(A)(15); 17.420.020(A) | Not set KCC 17.420.056
for Adult family home (group living); Permanent transitory accommodations, small, large, safe parks, and indoor (group living) Boarding houses shall meet the minimum density and shall not exceed the maximum density for the zone or six boarding rooms, whichever is greater. Each room shall be considered a dwelling unit when calculating the required minimum or maximum density. KCC 17.415.250(B)
for Group living (group living)3 |
| Maximum residents | “Adult family home” means a dwelling licensed pursuant to Chapter 70.128 RCW in which a person or persons provide personal care, special care, and room and board to a number of persons consistent with the state definition. KCC 17.110.045 | Not set KCC 17.415.250
for Group living (group living)3 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
20 ft KCC 17.420.056
for Group living (group living)3; Permanent transitory accommodations, small, large, safe parks, and indoor (group living) |
| Maximum front setback | No limit KCC 17.420.056; 17.420.040 | |
| Side setback | 5 ft KCC 17.420.056 | |
| Rear setback | 5 ft KCC 17.420.056 | |
| Maximum height | ||
| Maximum lot coverage | No limit KCC 17.420.056; 17.420.040 | |
| Maximum impervious surface | ||
| Minimum parking | 2 spaces per unit KCC 17.490.030 | Other uses not specifically listed above shall furnish parking as required by the director. The director shall use the above list as a guide for determining requirements for said other uses. KCC 17.490.030(B)(1)
for Adult family home (group living); Group living (group living)3; Permanent transitory accommodations, small, large, safe parks, and indoor (group living) |
| Maximum lot size | No limit KCC 17.420.056; 17.420.040 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit KCC 17.415.015(A)(4); 17.415.015(A)(6) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback |
|
|
| Side setback | 5 ft KCC 17.420.056 | |
| Rear setback | 5 ft KCC 17.420.056 | |
| Maximum height | ||
| Minimum parking | 1 space per unit KCC 17.415.015(A)(5); 17.490.030 | |
| Maximum unit size | 0.5 × floor area of the main house sq ft KCC 17.415.015(A)(2) | |
| Attached to the main house | Required KCC 17.415.015(A)(1); 17.110.017 | |
| Owner lives on site | Required KCC 17.415.015(A)(1) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision KCC 16.48.020 | A | up to 4 KCC 16.10.320(B) | — | Minimum lot size 10,890 sq ft KCC 17.420.056; 17.420.060(A)(12) Minimum lot width 60 ft KCC 17.420.056; 17.420.060(A)(12) Minimum lot depth 60 ft KCC 17.420.056; 17.420.060(A)(12) |
| Subdivision KCC 16.40.030 | H | 5 or more KCC 16.10.340 | — | Minimum lot size 10,890 sq ft KCC 17.420.056; 17.420.060(A)(12) Minimum lot width 60 ft KCC 17.420.056; 17.420.060(A)(12) Minimum lot depth 60 ft KCC 17.420.056; 17.420.060(A)(12) |
| Binding site plan KCC 16.56.040 | A14 | Minimum lots Not set KCC 16.56 |
— | Minimum lot size 10,890 sq ft KCC 17.420.056; 17.420.060(A)(12); 16.56.030(A) Minimum lot width 60 ft KCC 17.420.056; 17.420.060(A)(12); 16.56.030(A) Minimum lot depth 60 ft KCC 17.420.056; 17.420.060(A)(12); 16.56.030(A) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- The ADU is detached (not within or connected by at least 4 ft to the habitable space of the primary residence)
- The ADU is detached (not within or connected by at least 4 ft to the habitable space of the primary residence)
- Sleeping units in the project is at most 6
- Type of transitory accommodation is small
- Type of transitory accommodation is large
- Type of transitory accommodation is safe_park
- Type of transitory accommodation is indoor
- One or both abutting lots have dwellings with front yards less than the required depth
- None of these is true:
- One or both abutting lots have dwellings with front yards less than the required depth
- All of these are true:
- Lot is in the Manchester view protection overlay (Appendix B2)
- There is no existing view of downtown Seattle, the Cascade Mountains, Mt. Rainier or the Puget Sound from the subject property or any adjacent property
- The owners of all adjacent properties approve the building height prior to building permit issuance
- It can be explicitly shown that the structure will not cause the blockage of existing views from any of the adjacent properties
- Not all of these are true:
- Lot is in the Manchester view protection overlay (Appendix B2)
- None of these is true:
- There is no existing view of downtown Seattle, the Cascade Mountains, Mt. Rainier or the Puget Sound from the subject property or any adjacent property
- The owners of all adjacent properties approve the building height prior to building permit issuance
- It can be explicitly shown that the structure will not cause the blockage of existing views from any of the adjacent properties
- Lot area is at most 21,780 sf
- Lot area is more than 21,780 sf
- The land is divided through a condominium process under Chapter 64.32 or 64.34 RCW