PLA 5B · PLA 5B planned area
Kirkland, WA · KZC 30 · Official code
By right: 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Detached, Attached, or Stacked Dwelling Units | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Development Containing Stacked or Attached Dwelling Units and Office Uses | — | — | |||
| Assisted Living Facility | — | — | — | — | Home✓ ADU— |
| Co-Living Housing | — | — | — | — | |
| Convalescent Center | — | — | — | — | HomeA ADU— |
| Nursing Home | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | 3,600 sq ft KZC 30.30.060 | 7,200 sq ft KZC 30.30.050
for Convalescent Center (group living); Nursing Home (group living) |
| Maximum density | 1 unit per 1,800 sq ft KZC 30.30.060 | Not set KZC 30.30.010
for Assisted Living Facility (group living); Co-Living Housing (group living)2; Convalescent Center (group living); Nursing Home (group living) |
| Maximum sleeping units | Not set KZC 30.30.050 | 2 × (lot area ÷ 1,800, rounded down) sleeping units KZC 30.30.010; 30.30.060
for Assisted Living Facility (group living) 4 × (lot area ÷ 1,800, rounded down) sleeping units KZC 30.30.060; 111.25(1)
for Co-Living Housing (group living)2 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft KZC 30.30.060 | |
| Side setback | 5 ft KZC 30.30.010
for Assisted Living Facility (group living); Co-Living Housing (group living)2; Convalescent Center (group living); Nursing Home (group living) | |
| Total side setbacks | 15 ft KZC 30.30 DD-3 | |
| Rear setback | 10 ft KZC 30.30.010
for Assisted Living Facility (group living); Co-Living Housing (group living)2; Convalescent Center (group living); Nursing Home (group living) | |
| Maximum height | 30 ft KZC 30.30.060 | |
| Maximum lot coverage | 70% KZC 30.30.060 | |
| Minimum parking | 0 spaces per sleeping unit KZC 105.22(1)(b)(3)
for Assisted Living Facility (group living) for Co-Living Housing (group living)2 1 space per bed KZC 30.40.050
for Convalescent Center (group living) 0 spaces per bed KZC 105.22(1)(b)(4)
for Nursing Home (group living) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Planned Unit Development KZC 125.10 | H | — | Except as allowed under subsections (2) and (3) of this section, the maximum permitted residential density is the greater of that recommended by the Comprehensive Plan or 110 percent of that permitted in the zone in which the PUD is located. KZC 125.30(1) | Minimum lot size Not set KZC 125.25; 125.30 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The development contains office uses together with the dwelling units
- Lot area is at least 10,800 sf
- All of these are true:
- The side of the dwelling unit is attached to a dwelling unit on an adjoining lot
- The lot abuts a lot containing a low density use within the PLA 5A zone
- Not all of these are true:
- The side of the dwelling unit is attached to a dwelling unit on an adjoining lot
- None of these is true:
- The lot abuts a lot containing a low density use within the PLA 5A zone
- All of these are true:
- The rear of the dwelling unit is attached to a dwelling unit on an adjoining lot
- The lot abuts a lot containing a low density use within the PLA 5A zone
- Not all of these are true:
- The rear of the dwelling unit is attached to a dwelling unit on an adjoining lot
- None of these is true:
- The lot abuts a lot containing a low density use within the PLA 5A zone
- Any of these is true:
- Floor area of one unit is less than 1,200
- The unit is an Affordable Housing Unit
- None of these is true:
- Floor area of one unit is less than 1,200
- The unit is an Affordable Housing Unit
- Any of these is true:
- Floor area of one unit is less than 1,200
- Unit is located within one-half mile of a Major Transit Stop
- The unit is an Affordable Housing Unit
- None of these is true:
- Floor area of one unit is less than 1,200
- Unit is located within one-half mile of a Major Transit Stop
- The unit is an Affordable Housing Unit