JBD 6_O · Juanita Business District 6
Kirkland, WA · KZC 52 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Detached, Attached, or Stacked Dwelling Units | HomeA ADU✓ | HomeA ADU— | HomeA ADU— | — | |
| Assisted Living Facility | — | — | — | — | HomeA ADU— |
| Co-Living Housing | — | — | — | — | |
| Nursing Home | — | — | — | — | HomeA ADU— |
| Convalescent Center | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | (lot area ÷ 1,800, rounded down) + (2 × units that are income-restricted affordable housing) units KZC 52.42.060; 52.40(2) | |
| Minimum lot size | 3,600 sq ft KZC 52.42.060 | No limit KZC 52.42.120
for Nursing Home (group living); Convalescent Center (group living) |
| Maximum density | Not set KZC 52.42.060 | 1 unit per 1,800 sq ft KZC 52.42.060
for Detached, Attached, or Stacked Dwelling Units (1, 2, 3 units) |
| Maximum sleeping units | Not set KZC 52.42.120 | 2 × (lot area ÷ 1,800, rounded down) sleeping units KZC 52.42.110; 52.42.060
for Assisted Living Facility (group living) 4 × (lot area ÷ 1,800, rounded down) sleeping units KZC 52.42.060; 111.25(1)
for Co-Living Housing (group living)2 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft KZC 52.42.060 | |
| Side setback | 0 ft KZC 52.42.060 | |
| Rear setback | 0 ft KZC 52.42.060 | |
| Maximum height | ||
| Maximum lot coverage | 80% KZC 52.42.060 | |
| Minimum parking | for Detached, Attached, or Stacked Dwelling Units (1 unit) 0 spaces per sleeping unit KZC 105.22(1)(b)(3)
for Assisted Living Facility (group living) for Co-Living Housing (group living)2 0 spaces per bed KZC 105.22(1)(b)(4)
for Nursing Home (group living) 1 space per bed KZC 52.42.120
for Convalescent Center (group living) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units KZC 115.07 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft KZC 52.42.060; KZC 115.07(5) | |
| Side setback | 0 ft KZC 52.42.060; KZC 115.07(5) | |
| Rear setback | 0 ft KZC 52.42.060; KZC 115.07(5) | |
| Maximum height | ||
| Minimum parking | 0 spaces per unit KZC 105.22(1)(b)(2) | |
| Maximum unit size | 1,200 sq ft KZC 115.07(4) | |
| Attached to the main house | Not required KZC 115.07(5) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Planned Unit Development KZC 125.10 | H | — | Except as allowed under subsections (2) and (3) of this section, the maximum permitted residential density is the greater of that recommended by the Comprehensive Plan or 110 percent of that permitted in the zone in which the PUD is located. KZC 125.30(1) | Minimum lot size Not set KZC 125.25; 125.30 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- At least 10 percent of the units in the development are affordable housing units
- Lot could develop six or more units under the base zone
- None of these is true:
- The impacts of the additional height are mitigated by design techniques
- The impacts of the additional height are mitigated by design techniques
- Any of these is true:
- Floor area of one unit is less than 1,200
- The unit is an Affordable Housing Unit
- None of these is true:
- Floor area of one unit is less than 1,200
- The unit is an Affordable Housing Unit
- Any of these is true:
- Floor area of one unit is less than 1,200
- Unit is located within one-half mile of a Major Transit Stop
- The unit is an Affordable Housing Unit
- None of these is true:
- Floor area of one unit is less than 1,200
- Unit is located within one-half mile of a Major Transit Stop
- The unit is an Affordable Housing Unit