HENC 3 · HENC 3 commercial zone
Kirkland, WA · KZC 35 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Attached or Stacked Dwelling Units | — | — | |||
| Assisted Living Facility | — | — | — | — | |
| Co-Living Housing | — | — | — | — | |
| Convalescent Center | — | — | — | — | HomeA ADU— |
| Nursing Home | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
No standards.
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | Same as the regulations for the ground floor use. KZC 35.30 DD-4 | 10 ft KZC 35.30.060
for Convalescent Center (group living); Nursing Home (group living) |
| Side setback | Same as the regulations for the ground floor use. KZC 35.30 DD-4 | 0 ft KZC 35.30.060
for Convalescent Center (group living); Nursing Home (group living) |
| Rear setback | Same as the regulations for the ground floor use. KZC 35.30 DD-4 | 0 ft KZC 35.30.060
for Convalescent Center (group living); Nursing Home (group living) |
| Maximum height | Same as the regulations for the ground floor use. KZC 35.30 DD-4 | 30 ft KZC 35.30.060
for Convalescent Center (group living); Nursing Home (group living) |
| Maximum lot coverage | Same as the regulations for the ground floor use. KZC 35.30 DD-4 | 80% KZC 35.30.060
for Convalescent Center (group living); Nursing Home (group living) |
| Minimum parking | 0 spaces per sleeping unit KZC 105.22(1)(b)(3)
for Assisted Living Facility (group living)1 for Co-Living Housing (group living)1 1 space per bed KZC 35.40.060
for Convalescent Center (group living) 0 spaces per bed KZC 105.22(1)(b)(4)
for Nursing Home (group living) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Planned Unit Development KZC 125.10 | H | — | Except as allowed under subsections (2) and (3) of this section, the maximum permitted residential density is the greater of that recommended by the Comprehensive Plan or 110 percent of that permitted in the zone in which the PUD is located. KZC 125.30(1) | Minimum lot size Not set KZC 125.25; 125.30 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The development puts the commercial or other non-residential uses the code requires on the street level (ground) floor, with dwelling units above or behind them
- Any of these is true:
- Floor area of one unit is less than 1,200
- The unit is an Affordable Housing Unit
- None of these is true:
- Floor area of one unit is less than 1,200
- The unit is an Affordable Housing Unit
- Any of these is true:
- Floor area of one unit is less than 1,200
- Unit is located within one-half mile of a Major Transit Stop
- The unit is an Affordable Housing Unit
- None of these is true:
- Floor area of one unit is less than 1,200
- Unit is located within one-half mile of a Major Transit Stop
- The unit is an Affordable Housing Unit