Sign in

HENC 2 · Houghton/Everest Neighborhood Center 2

Kirkland, WA · KZC 25 · Official code

By right: 1 unit · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Detached Dwelling Unit
Home✓ ADU✓
————
Detached, Attached, or Stacked Dwelling Units—
HomeA ADU—
HomeA ADU—
HomeA ADU—
—
Middle Housing—
Home✓1 ADU✓1
Home✓1 ADU✓1
Home✓1 ADU✓1
—
Assisted Living Facility————
HomeA ADU—
Co-Living Housing————
HomeA ADU—
Convalescent Center————
HomeH ADU—
Nursing Home————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set KZC 25.30.050
  • 6 units2 KZC 113.25; 25.20 PU-13
  • 4 units3 KZC 113.25; 25.20 PU-13
for Middle Housing (4+ units)1
Minimum unitsNot set KZC 25.30.050
No limit KZC 113.25
for Middle Housing (4+ units)1
Minimum lot size3,600 sq ft KZC 25.30.060
No limit KZC 113.25
for Middle Housing (2, 3, 4+ units)1
7,200 sq ft KZC 25.30.040
for Convalescent Center (group living); Nursing Home (group living)
Minimum densityNot set KZC 25.30.060
Medium and high-density zones have a minimum density that is 80 percent of the maximum allowed density. Middle housing projects must provide no fewer than the minimum number of units established by the base zoning before this chapter’s density calculations are applied. KZC 113.25
for Middle Housing (2, 3, 4+ units)1
Maximum densityNot set KZC 25.30.060
No limit KZC 25.30.050
for Detached, Attached, or Stacked Dwelling Units (2, 3, 4+ units)
A development more than a quarter-mile walking distance of a major transit stop may have the greater of: Four units per lot; or Twice the maximum number of Detached Dwelling Units allowed in the residential zones. KZC 113.25
for Middle Housing (2, 3, 4+ units)1
For density purposes, two assisted living units shall constitute one dwelling unit. Total dwelling units may not exceed the number of stacked dwelling units allowed on the subject property. KZC 25.30 DD-1
for Assisted Living Facility (group living)

3. Building standards

StandardValueExceptions
Front setback10 ft KZC 25.30.050
20 ft KZC 25.30.060
for Detached Dwelling Unit (1 unit); Middle Housing (2, 3, 4+ units)1
Side setback0 ft KZC 25.30.050
5 ft KZC 25.30.060
for Detached Dwelling Unit (1 unit); Middle Housing (2, 3, 4+ units)1
Total side setbacksNot set KZC 25.30.050
15 ft KZC 25.30 DD-4
for Detached Dwelling Unit (1 unit)
Street side setbackNot set KZC 25.30.060
5 ft KZC 113.25
for Middle Housing (2, 3, 4+ units)1
Rear setback0 ft KZC 25.30.050
10 ft KZC 25.30.060
for Detached Dwelling Unit (1 unit); Middle Housing (2, 3, 4+ units)1
Maximum height30 ft KZC 25.30.060
Maximum lot coverage80% KZC 25.30.050
60% KZC 25.30.060
for Detached Dwelling Unit (1 unit); Middle Housing (2, 3, 4+ units)1
Minimum parking
  • 0 spaces per unit4 KZC 105.22(1)(b)(1); 105.22(1)(b)(5)
  • 0.5 spaces per unit5 KZC 105.22(2)(a)(2)
  • 0 spaces per unit4 KZC 105.22(1)(b)(1); 105.22(1)(b)(5)
  • 1 space per unit5 KZC 105.22(2)(a)(1)
for Detached Dwelling Unit (1 unit)
0 spaces per sleeping unit KZC 105.22(1)(b)(3)
for Assisted Living Facility (group living)
  • 0 spaces per unit6 KZC 111.25(2)(a); 105.22(1)(b)(1); 105.22(1)(b)(5)
  • 0.5 spaces per unit7 KZC 105.22(2)(a)(2)
for Co-Living Housing (group living)
1 space per bed KZC 25.40.040
for Convalescent Center (group living)
0 spaces per bed KZC 105.22(1)(b)(4)
for Nursing Home (group living)
Maximum unit sizeNot set KZC 25.30.060
800 square feet for Carriage Units, 1,700 square feet for Cottage units KZC 113.25
for Middle Housing (2, 3, 4+ units)1

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units KZC 115.07

Building

StandardValueExceptions
Front setback20 ft KZC 25.30.060; KZC 115.07(5)
Side setback5 ft KZC 25.30.060; KZC 115.07(5)
Rear setback10 ft KZC 25.30.060; KZC 115.07(5)
Maximum height30 ft KZC 25.30.060; KZC 115.07(5)
Minimum parking0 spaces per unit KZC 105.22(1)(b)(2)
Maximum unit size1,200 sq ft KZC 115.07(4)
Attached to the main houseNot required KZC 115.07(5)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Planned Unit Development KZC 125.10 H — Except as allowed under subsections (2) and (3) of this section, the maximum permitted residential density is the greater of that recommended by the Comprehensive Plan or 110 percent of that permitted in the zone in which the PUD is located. KZC 125.30(1)
Minimum lot size
Not set KZC 125.25; 125.30

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. None of these is true:
    • Property is within the jurisdiction of the Shoreline Management Act regulated under Chapter 83 KZC
    • Property has a Goat Hill (GH) Overlay
  2. Lot is within a quarter-mile walking distance of a major transit stop
  3. None of these is true:
    • Lot is within a quarter-mile walking distance of a major transit stop
  4. Any of these is true:
    • Floor area of one unit is less than 1,200
    • The unit is an Affordable Housing Unit
  5. None of these is true:
    • Floor area of one unit is less than 1,200
    • The unit is an Affordable Housing Unit
  6. Any of these is true:
    • Floor area of one unit is less than 1,200
    • Unit is located within one-half mile of a Major Transit Stop
    • The unit is an Affordable Housing Unit
  7. None of these is true:
    • Floor area of one unit is less than 1,200
    • Unit is located within one-half mile of a Major Transit Stop
    • The unit is an Affordable Housing Unit