NR-4B · Neighborhood Residential 4B
Kent, WA · KCC 15.03.010; 15.04.020; 15.04.170 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Detached or single-family dwelling | Home✓ ADUA | — | — | — | — |
| One modular home per lot | Home✓ ADUA | — | — | — | — |
| Designated manufactured home | — | — | — | — | |
| Permanent supportive housing | Home✓ ADUA | Home✓ ADUA | Home✓ ADUA | Home✓ ADUA | — |
| Duplex | — | Home✓ ADUA | — | — | — |
| Townhouse | — | Home✓ ADUA | Home✓ ADUA | Home✓ ADUA | — |
| Stacked flats | — | Home✓ ADUA | Home✓ ADUA | Home✓ ADUA | — |
| Courtyard apartments | — | — | Home✓ ADUA | Home✓ ADUA | — |
| Fiveplex | — | — | — | Home✓ ADUA | — |
| Sixplex | — | — | — | Home✓ ADUA | — |
| Multifamily dwellings | — | — | — | Home✓ ADUA | — |
| Mobile home parks | — | — | — | — | |
| Group homes class I | — | — | — | — | |
| Group homes class II-A | — | — | — | — | |
| Group homes class II-B | — | — | — | — | |
| Group homes class II-C | — | — | — | — | |
| Communal residences tier 1 | — | — | — | — | |
| Communal residences tier 2 | — | — | — | — | |
| Transitional housing | — | — | — | — | Home✓ ADUA |
| Outside emergency shelter | — | — | — | — | |
| Independent senior living facilities | — | — | — | — | Home✓ ADUA |
| Assisted living facilities | — | — | — | — | Home✓ ADUA |
| Residential facilities with health care | — | — | — | — | Home✓ ADUA |
| Enhanced service facility | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set KCC 15.04.170 | 5 units KCC 15.02.152
for Fiveplex (4+ units) 6 units KCC 15.02.491
for Sixplex (4+ units) |
| Minimum units | Not set KCC 15.04.020 | 5 units KCC 15.02.152
6 units KCC 15.02.491
for Sixplex (4+ units) 7 units KCC 15.02.125
for Multifamily dwellings (4+ units) |
| Minimum lot size | No limit KCC 15.04.170 | 87,120 sq ft KCC 15.04.030(31)(b)(ii)
for Outside emergency shelter (group living)8 |
| Minimum lot width | 80 ft KCC 15.04.170; 15.04.180(4) | |
| Maximum density | 40 units per acre, ADUs included KCC 15.04.170; 15.04.180(27)(a) | 9 units per acre KCC 12.05.200
for Mobile home parks (4+ units)2 Not set KCC 15.04.170
for Group homes class I (group living); Group homes class II-A (group living)4; Group homes class II-B (group living)4; Group homes class II-C (group living)4; Communal residences tier 1 (group living)6; Communal residences tier 2 (group living)7; Transitional housing (group living); Outside emergency shelter (group living)8; Independent senior living facilities (group living); Assisted living facilities (group living); Residential facilities with health care (group living) No limit KCC 15.04.180(2)
for Enhanced service facility (group living)9 |
| Maximum residents | Not set KCC 15.04.170 | 8 persons KCC 15.02.173(B)(1)
for Group homes class II-A (group living)4 12 persons KCC 15.02.173(B)(2)
for Group homes class II-B (group living)4 18 persons KCC 15.02.173(B)(3)
for Group homes class II-C (group living)4 35 persons KCC 15.04.030(31)(b)(i)
for Outside emergency shelter (group living)8 |
| Maximum beds | Not set KCC 15.04.170 | 1 × ((40 × lot area) ÷ 43,560, rounded down) beds KCC 15.04.170; 15.04.030(29)
for Transitional housing (group living) |
| Maximum sleeping units | Not set KCC 15.04.170 | 3 sleeping units KCC 15.04.030(33)(a)(iii)
for Communal residences tier 1 (group living)6 4 × ((40 × lot area) ÷ 43,560, rounded down) sleeping units KCC 15.04.170; 15.04.030(33)(b)(iii)
for Communal residences tier 2 (group living)7 1 × ((40 × lot area) ÷ 43,560, rounded down) sleeping units KCC 15.04.170; 15.04.030(29)
for Independent senior living facilities (group living); Assisted living facilities (group living); Residential facilities with health care (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft KCC 15.04.170; 15.04.180(6); 15.04.180(8) | 20 ft KCC 15.04.030(31)(a)(vi); 15.08.020(A)(2)
for Outside emergency shelter (group living)8 |
| Side setback | the largest of 5, the smallest of 0.1 × lot width, 30 ft KCC 15.04.170; 15.04.180(11) | 5 ft KCC 12.05.180
for Mobile home parks (4+ units)2 15 ft KCC 15.04.030(31)(a)(vi); 15.08.020(A)(3)
for Outside emergency shelter (group living)8 10 ft KCC 15.04.180(3)(a)
for Enhanced service facility (group living)9 |
| Street side setback | 15 ft KCC 15.04.170 | |
| Rear setback | 20 ft KCC 15.04.170 | 5 ft KCC 12.05.180
for Mobile home parks (4+ units)2 10 ft KCC 15.04.180(3)(a)
for Enhanced service facility (group living)9 |
| Building separation | the largest of 12, building height ft KCC 15.04.170; 15.04.180(15) | 15 ft KCC 12.05.180
for Mobile home parks (4+ units)2 |
| Maximum height | 50 ft KCC 15.04.170 | |
| Maximum stories | 4 stories KCC 15.04.170 | |
| Maximum lot coverage | 55% KCC 15.04.170; 15.04.180(5) | 40% KCC 12.05.190
for Mobile home parks (4+ units)2 |
| Minimum parking | 2 spaces per unit KCC 15.05.040(A) | For uses not specifically identified in this section, the amount of parking required shall be determined by the planning department, based on staff experience, parking required for similar uses, and, if appropriate, documentation provided by the applicant. KCC 15.05.040(A)
for Permanent supportive housing (1, 2, 3, 4+ units); Transitional housing (group living); Outside emergency shelter (group living)8; Independent senior living facilities (group living); Assisted living facilities (group living) for Multifamily dwellings (4+ units) (2 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 10, rounded down) spaces KCC 15.05.040(A); 12.05.230(B); 12.05.250(B)
for Mobile home parks (4+ units)2 for Communal residences tier 1 (group living)6 for Communal residences tier 2 (group living)7 (employees on the largest shift ÷ 2) + (beds in the project ÷ 3) spaces KCC 15.05.040(A)
for Residential facilities with health care (group living) employees on the largest shift + (beds in the project ÷ 3) spaces KCC 15.05.040(A)
for Enhanced service facility (group living)9 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units KCC 15.08.350(B)(2) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft KCC 15.04.170; 15.04.180(6); 15.04.180(8) | 20 ft KCC 15.04.030(31)(a)(vi); 15.08.020(A)(2)
for Outside emergency shelter (group living)8 |
| Side setback | for Outside emergency shelter (group living)8 | |
| Rear setback | ||
| Maximum height | ||
| Maximum stories | 4 stories KCC 15.08.350(B)(8); 15.04.170 | |
| Minimum parking | ||
| Maximum unit size | 1,000 sq ft KCC 15.08.350(B)(6) | |
| Attached to the main house | Not required KCC 15.08.350(B)(2)(a)-(c) | |
| Owner lives on site | Not required KCC 15.08.350(B)(9) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision KCC 12.01.040(A); 12.04.185 | A | up to 9 KCC 12.04.025(MM); 12.04.105(A) | — | Minimum lot size No limit KCC 15.04.170 Minimum lot width 80 ft KCC 15.04.170; 15.04.180(4) |
| Subdivision KCC 12.01.040(A); 12.04.177; 12.04.192 | H | 10 or more KCC 12.04.025(OO); 12.04.107(A) | — | Minimum lot size No limit KCC 15.04.170 Minimum lot width 80 ft KCC 15.04.170; 15.04.180(4) |
| Unit lot subdivision KCC 12.04.260(A); 12.01.040(A) | A | up to 9 KCC 12.04.260(A); 12.04.025(TT); 12.04.025(MM) | — | Minimum lot size A unit lot may be as small as the footprint of the dwelling unit it contains, provided it meets applicable requirements KCC 12.04.260(D)(3) |
| Planned unit development KCC 15.08.400(A); 12.04.050; 12.01.040(A) | H | Maximum lots Not set KCC 15.08.400 |
— | Minimum lot size No limit KCC 15.08.400(C)(1) |
| Binding site plan KCC 12.04.805(B); 12.01.040(A) | A | Maximum lots Not set KCC 12.04.800 |
— | Minimum lot size Not set KCC 12.04.800 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The designated manufactured home is a new manufactured home
- Lot has approved mobile home park combining district regulations and development plans
- The ADU is used as part of the operation of the group home and is not leased or subleased to a separate family
- None of these is true:
- Another approved group home is located within 1,000 feet of the proposed class II or III group home
- A public school is within 1,000 feet of the proposed class II or III group home
- Another class II or III group home is within 600 feet
- A school, church or religious facility, park, playground or other sensitive use is within 1,000 feet
- All of these are true:
- The ADU is used as part of the operation of the group home and is not leased or subleased to a separate family
- Another approved group home is located within 1,000 feet of the proposed class II or III group home
- A public school is within 1,000 feet of the proposed class II or III group home
- Another class II or III group home is within 600 feet
- A school, church or religious facility, park, playground or other sensitive use is within 1,000 feet
- All of these are true:
- Lot area is less than 6,534 sf
- The tier 1 communal residence is within a single-family dwelling unit or an accessory dwelling unit
- Lot area is at least 6,534 sf
- All of these are true:
- An actively operating religious organization is on the same lot
- Another approved emergency housing, indoor emergency shelter, or outside emergency shelter facility is within 1,000 feet
- All of these are true:
- The site meets the school separation buffer of KCC 15.02.340.2
- An existing behavioral health facility is within 500 feet of the lot
- The class I group home is an adult family home approved for eight residents pursuant to RCW 70.128.010 and 70.128.066
- None of these is true:
- The class I group home is an adult family home approved for eight residents pursuant to RCW 70.128.010 and 70.128.066
- Bedrooms in one unit is at most 0
- All of these are true:
- Bedrooms in one unit is at least 1
- Main dwelling units on the lot is at most 49
- All of these are true:
- Bedrooms in one unit is at least 1
- Main dwelling units on the lot is at least 50
- Lot is within one-half-mile walking distance of a major transit stop
- None of these is true:
- Lot is within one-half-mile walking distance of a major transit stop
- All of these are true:
- The ADU is detached
- The detached ADU is located in the rear one-half of the lot
- Not all of these are true:
- The ADU is detached
- The detached ADU is located in the rear one-half of the lot
- The ADU is detached
- None of these is true:
- The ADU is detached