I1 · Industrial Business District
Kent, WA · KCC 15.03.010; 15.04.020; 15.04.190 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Permanent supportive housing | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Multifamily dwellings | — | — | — | — | |
| Secure community transition facilities | — | — | — | — | |
| Communal residences tier 2 | — | — | — | — | |
| Transitional housing | — | — | — | — | Home✓ ADU— |
| Emergency housing facility; indoor emergency shelter | — | — | — | — | |
| Outside emergency shelter | — | — | — | — | |
| Isolation and quarantine facilities | — | — | — | — | HomeH ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum units | 7 units KCC 15.02.125 | Not set KCC 15.04.020
for Permanent supportive housing (4+ units) |
| Minimum lot size | 10,000 sq ft KCC 15.04.190 | 43,560 sq ft KCC 15.04.030(35)(a)(ii)
for Emergency housing facility; indoor emergency shelter (group living)4 87,120 sq ft KCC 15.04.030(31)(b)(ii)
for Outside emergency shelter (group living)5 |
| Maximum density | Not set KCC 15.04.190 | Multifamily buildings are subject to a maximum dwelling unit density that is equal to the number of hotel rooms. KCC 15.04.030(12)
for Multifamily dwellings (4+ units)1 |
| Maximum residents | Not set KCC 15.04.190 |
for Secure community transition facilities (group living)2 35 persons KCC 15.04.030(31)(b)(i)
for Outside emergency shelter (group living)5 |
| Maximum sleeping units | Not set KCC 15.04.190 | Tier 2 communal residences are subject to a maximum dwelling unit density that is four times the number of hotel rooms. KCC 15.04.030(12)
for Communal residences tier 2 (group living)3 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 15 ft KCC 15.04.190 | 20 ft KCC 15.04.030(31)(a)(vi); 15.08.020(A)(2)
for Outside emergency shelter (group living)5 |
| Side setback | ||
| Street side setback | 15 ft KCC 15.04.190 | |
| Rear setback | ||
| Maximum height | 85 ft KCC 15.04.190 | |
| Maximum stories | 8 stories KCC 15.04.190 | |
| Maximum lot coverage | 60% KCC 15.04.190 | |
| Minimum parking | For uses not specifically identified in this section, the amount of parking required shall be determined by the planning department, based on staff experience, parking required for similar uses, and, if appropriate, documentation provided by the applicant. KCC 15.05.040(A) | for Multifamily dwellings (4+ units)1 |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision KCC 12.01.040(A); 12.04.185 | A | up to 9 KCC 12.04.025(MM); 12.04.105(A) | — | Minimum lot size 10,000 sq ft KCC 15.04.190 |
| Subdivision KCC 12.01.040(A); 12.04.177; 12.04.192 | H | 10 or more KCC 12.04.025(OO); 12.04.107(A) | — | Minimum lot size 10,000 sq ft KCC 15.04.190 |
| Unit lot subdivision KCC 12.04.260(A); 12.01.040(A) | A | up to 9 KCC 12.04.260(A); 12.04.025(TT); 12.04.025(MM) | — | Minimum lot size A unit lot may be as small as the footprint of the dwelling unit it contains, provided it meets applicable requirements KCC 12.04.260(D)(3) |
| Planned unit development KCC 15.08.400(A); 12.04.050; 12.01.040(A) | H | Maximum lots Not set KCC 15.08.400 |
— | Minimum lot size No limit KCC 15.08.400(C)(1) |
| Binding site plan KCC 12.04.805(B); 12.01.040(A) | A | Maximum lots Not set KCC 12.04.800 |
— | Minimum lot size Not set KCC 12.04.800 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- A hotel or motel exists on the parcel as of August 17, 2021
- All of these are true:
- Lot is within the boundaries on the secure community transition facility map
- The site is at least 600 feet from any other class II or III group home
- The site is adjacent to, immediately across the street or parking lot from, or within the line of sight of risk-potential activities or facilities
- All of these are true:
- A hotel or motel exists on the parcel as of August 17, 2021
- Six or more dwelling units are permitted on the lot, not only through the affordable housing density bonus of KCC 15.04.180(27)(c)
- None of these is true:
- Another approved emergency housing, indoor emergency shelter, or outside emergency shelter facility is within 1,000 feet
- All of these are true:
- An actively operating religious organization is on the same lot
- Another approved emergency housing, indoor emergency shelter, or outside emergency shelter facility is within 1,000 feet
- The state agency demonstrates it has equitably distributed other secure community transition facilities with the same or more residents throughout King County
- None of these is true:
- The state agency demonstrates it has equitably distributed other secure community transition facilities with the same or more residents throughout King County
- Transitional conditions exist: the district adjoins a residential district of two or more dwelling units per acre, with no intervening use
- None of these is true:
- Transitional conditions exist: the district adjoins a residential district of two or more dwelling units per acre, with no intervening use
- Bedrooms in one unit is at most 0
- All of these are true:
- Bedrooms in one unit is at least 1
- Main dwelling units on the lot is at most 49
- All of these are true:
- Bedrooms in one unit is at least 1
- Main dwelling units on the lot is at least 50
- Lot is within one-half-mile walking distance of a major transit stop
- None of these is true:
- Lot is within one-half-mile walking distance of a major transit stop