Sign in

CC-MU · Community Commercial – Mixed Use

Kent, WA · KCC 15.03.010; 15.04.020; 15.04.190 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Live-work units
Home✓1 ADU—
————
Permanent supportive housing
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Townhouse—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Fourplex———
Home✓1 ADU—
—
Fiveplex———
Home✓1 ADU—
—
Sixplex———
Home✓1 ADU—
—
Multifamily dwellings———
Home✓1 ADU—
—
Group homes class I————
Home✓ ADU—
Group homes class II-A————
HomeH2 ADU—
Group homes class II-B————
HomeH2 ADU—
Group homes class II-C————
HomeH2 ADU—
Group homes class III————
HomeH3 ADU—
Communal residences tier 2————
Home✓1 ADU—
Transitional housing————
Home✓1 ADU—
Outside emergency shelter————
HomeH4 ADU—
Independent senior living facilities————
Home✓5 ADU—
Assisted living facilities————
Home✓5 ADU—
Residential facilities with health care————
Home✓5 ADU—
Enhanced service facility————
HomeH6 ADU—
Intensive behavioral health treatment facility————
HomeH6 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum unitsNot set KCC 15.04.190
4 units KCC 15.02.153
for Fourplex (4+ units)1
5 units KCC 15.02.152
for Fiveplex (4+ units)1
6 units KCC 15.02.491
for Sixplex (4+ units)1
Minimum unitsNot set KCC 15.04.020
4 units KCC 15.02.153
for Fourplex (4+ units)1
5 units KCC 15.02.152
for Fiveplex (4+ units)1
6 units KCC 15.02.491
for Sixplex (4+ units)1
7 units KCC 15.02.125
for Multifamily dwellings (4+ units)1
Minimum lot size10,000 sq ft KCC 15.04.190
87,120 sq ft KCC 15.04.030(31)(b)(ii)
for Outside emergency shelter (group living)4
Maximum residentsNot set KCC 15.04.190
  • 8 persons7 KCC 15.02.173(A)
  • 6 persons8 KCC 15.02.173(A)
for Group homes class I (group living)
8 persons KCC 15.02.173(B)(1)
for Group homes class II-A (group living)2
12 persons KCC 15.02.173(B)(2)
for Group homes class II-B (group living)2
18 persons KCC 15.02.173(B)(3)
for Group homes class II-C (group living)2
35 persons KCC 15.04.030(31)(b)(i)
for Outside emergency shelter (group living)4
Maximum sleeping unitsNot set KCC 15.04.190
In zones without a dwelling unit density limit, the maximum number of sleeping units shall be determined by building bulk, height, lot coverage, and applicable building code standards. KCC 15.04.030(33)(b)(iii)
for Communal residences tier 2 (group living)1

3. Building standards

StandardValueExceptions
Front setback10 ft KCC 15.04.190
20 ft KCC 15.04.030(31)(a)(vi); 15.08.020(A)(2)
for Outside emergency shelter (group living)4
Side setback
  • 20 ft9 KCC 15.04.195(9)
  • 0 ft10 KCC 15.04.195(9)
  • 20 ft9 KCC 15.04.195(9)
  • 15 ft10 KCC 15.04.030(31)(a)(vi); 15.08.020(A)(3)
for Outside emergency shelter (group living)4
10 ft KCC 15.04.195(7)
for Enhanced service facility (group living)6; Intensive behavioral health treatment facility (group living)6
Rear setback
  • 20 ft9 KCC 15.04.195(9)
  • 0 ft10 KCC 15.04.195(9)
20 ft KCC 15.04.030(31)(a)(vi); 15.08.020(A)(4)
for Outside emergency shelter (group living)4
10 ft KCC 15.04.195(7)
for Enhanced service facility (group living)6; Intensive behavioral health treatment facility (group living)6
Maximum stories
  • 7 stories11 KCC 15.04.190; 15.04.195(33)
  • 5 stories12 KCC 15.04.190
Maximum lot coverage80% KCC 15.04.190
Minimum parking2 spaces per unit KCC 15.05.040(A)
For uses not specifically identified in this section, the amount of parking required shall be determined by the planning department, based on staff experience, parking required for similar uses, and, if appropriate, documentation provided by the applicant. KCC 15.05.040(A)
for Live-work units (1 unit)1; Permanent supportive housing (1, 2, 3, 4+ units)1; Transitional housing (group living)1; Outside emergency shelter (group living)4; Independent senior living facilities (group living)5; Assisted living facilities (group living)5
  • 1 space per unit13 KCC 15.05.040(A)
  • 2 spaces per unit14 KCC 15.05.040(A)
  • 1.8 spaces per unit15 KCC 15.05.040(A)
for Multifamily dwellings (4+ units)1
  • 0 spaces per sleeping unit16 KCC 15.05.040(A)
  • 0.25 × sleeping units in the project, rounded up spaces17 KCC 15.05.040(A)
for Communal residences tier 2 (group living)1
(employees on the largest shift ÷ 2) + (beds in the project ÷ 3) spaces KCC 15.05.040(A)
for Residential facilities with health care (group living)5
employees on the largest shift + (beds in the project ÷ 3) spaces KCC 15.05.040(A)
for Enhanced service facility (group living)6; Intensive behavioral health treatment facility (group living)6

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision KCC 12.01.040(A); 12.04.185 A up to 9 KCC 12.04.025(MM); 12.04.105(A) —
Minimum lot size
10,000 sq ft KCC 15.04.190
Subdivision KCC 12.01.040(A); 12.04.177; 12.04.192 H 10 or more KCC 12.04.025(OO); 12.04.107(A) —
Minimum lot size
10,000 sq ft KCC 15.04.190
Unit lot subdivision KCC 12.04.260(A); 12.01.040(A) A up to 9 KCC 12.04.260(A); 12.04.025(TT); 12.04.025(MM) —
Minimum lot size
A unit lot may be as small as the footprint of the dwelling unit it contains, provided it meets applicable requirements KCC 12.04.260(D)(3)
Planned unit development KCC 15.08.400(A); 12.04.050; 12.01.040(A) H
Maximum lots
Not set KCC 15.08.400
—
Minimum lot size
No limit KCC 15.08.400(C)(1)
Binding site plan KCC 12.04.805(B); 12.01.040(A) A
Maximum lots
Not set KCC 12.04.800
—
Minimum lot size
Not set KCC 12.04.800

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Any of these is true:
    • The residential use is included within a mixed-use development
    • Lot is within one-fourth mile of 104th Avenue SE
  2. None of these is true:
    • Another approved group home is located within 1,000 feet of the proposed class II or III group home
    • A public school is within 1,000 feet of the proposed class II or III group home
    • Another class II or III group home is within 600 feet
    • A school, church or religious facility, park, playground or other sensitive use is within 1,000 feet
  3. None of these is true:
    • Another approved group home is located within 1,000 feet of the proposed class II or III group home
    • A public school is within 1,000 feet of the proposed class II or III group home
    • Another class II or III group home is within 600 feet
    • A school, church or religious facility, park, playground or other sensitive use is within 1,000 feet
    • A residential area is within 1,000 feet
  4. All of these are true:
    • An actively operating religious organization is on the same lot
    None of these is true:
    • Another approved emergency housing, indoor emergency shelter, or outside emergency shelter facility is within 1,000 feet
  5. All of these are true:
    • Any of these is true:
      • The residential use is included within a mixed-use development
      • Lot is within one-fourth mile of 104th Avenue SE
    • Any of these is true:
      • Lot is within one-half mile of publicly accessible amenities in at least three of the listed categories
      • The facility provides public-facing amenities in one or more of the listed categories on its ground floor
  6. All of these are true:
    • The site meets the school separation buffer of KCC 15.02.340.2
    None of these is true:
    • An existing behavioral health facility is within 500 feet of the lot
  7. The class I group home is an adult family home approved for eight residents pursuant to RCW 70.128.010 and 70.128.066
  8. None of these is true:
    • The class I group home is an adult family home approved for eight residents pursuant to RCW 70.128.010 and 70.128.066
  9. The side or rear yard abuts a neighborhood residential zone
  10. None of these is true:
    • The side or rear yard abuts a neighborhood residential zone
  11. Structured parking or commercial uses are provided onsite
  12. None of these is true:
    • Structured parking or commercial uses are provided onsite
  13. Bedrooms in one unit is at most 0
  14. All of these are true:
    • Bedrooms in one unit is at least 1
    • Main dwelling units on the lot is at most 49
  15. All of these are true:
    • Bedrooms in one unit is at least 1
    • Main dwelling units on the lot is at least 50
  16. Lot is within one-half-mile walking distance of a major transit stop
  17. None of these is true:
    • Lot is within one-half-mile walking distance of a major transit stop