R · R Zone - Residential
Harrah, WA · HMC 360-10; 360-11; 360-12; 360-13 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwellings | Home✓ ADU— | — | — | — | — |
| Manufactured homes | — | — | — | — | |
| Multifamily dwelling structures | — | Home✓ ADU— | Home✓ ADU— | Home✓ ADU— | — |
| Adult family homes | — | — | — | — | Home✓ ADU— |
| Group care for children | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 4 units HMC 360-10B | Not set HMC 360-12A
for Multifamily dwelling structures (4+ units) |
| Minimum units | Not set HMC 360-10B | 5 units HMC 360-12A
for Multifamily dwelling structures (4+ units) |
| Minimum lot size | 7,200 sq ft HMC 360-13A(1) | |
| Minimum lot width | 60 ft HMC 360-13A(2) | |
| Minimum lot depth | 100 ft HMC 360-13A(3) | |
| Minimum frontage | ||
| Maximum residents | 6 persons HMC 360-5D | Not set HMC 360-10C; 360-5D
for Group care for children (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft HMC 360-13A(5) | |
| Side setback | 8 ft HMC 360-13A(6) | |
| Rear setback | 10 ft HMC 360-13A(7)(a) | |
| Maximum height | 35 ft HMC 360-13A(8) | |
| Maximum lot coverage | 40% HMC 360-13A(4) | |
| Minimum parking | 1.5 spaces per unit HMC 360-43A(2); 360-42A | 2 spaces per unit HMC 360-43A(1); 360-42A
Requirements for uses not listed shall be determined by the administrative official. HMC 360-42B
for Adult family homes (group living); Group care for children (group living) |
| Maximum units per building | Not set HMC 360-10A; 360-13A | 4 units HMC 360-10B
for Multifamily dwelling structures (2, 3, 4+ units) |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision HMC 340-24A; 340-24D; 340-25B(3) | A | 2 to 4 HMC 340-9; HMC 340-24A; 340-9 | Minimum average lot size 7,200 sq ft HMC 340-46B(1) |
Minimum lot size 7,200 sq ft HMC 360-13A(1); 340-46B(1) Minimum lot width 60 ft HMC 360-13A(2); 340-46B(5)(b) Minimum lot depth 100 ft HMC 360-13A(3) Maximum units per lot Not set HMC 340-46B; 360-10 |
| Subdivision HMC 340-11A; 340-15A | H | 5 or more HMC 340-11A; 340-9 | Minimum average lot size 7,200 sq ft HMC 340-46B(1) |
Minimum lot size 7,200 sq ft HMC 360-13A(1); 340-46B(1) Minimum lot width 60 ft HMC 360-13A(2); 340-46B(5)(b) Minimum lot depth 100 ft HMC 360-13A(3) Maximum units per lot Not set HMC 340-46B; 360-10 |
| Binding site plan HMC 340-40; 340-38AOnly for: Multifamily dwelling structures | H4 | Maximum lots Design and development standards of this chapter will be used as a basis for the design and development of the binding site plan. Certain standards may be modified or deleted where appropriate to address the concept of the development while still meeting the intent of this article. HMC 340-38B; 340-36A |
— | Minimum lot size Design and development standards of this chapter will be used as a basis for the design and development of the binding site plan. Certain standards may be modified or deleted where appropriate to address the concept of the development while still meeting the intent of this article. HMC 340-38B; 340-36A Minimum lot width Design and development standards of this chapter will be used as a basis for the design and development of the binding site plan. Certain standards may be modified or deleted where appropriate to address the concept of the development while still meeting the intent of this article. HMC 340-38B; 340-36A Minimum lot depth Design and development standards of this chapter will be used as a basis for the design and development of the binding site plan. Certain standards may be modified or deleted where appropriate to address the concept of the development while still meeting the intent of this article. HMC 340-38B; 340-36A Minimum frontage Design and development standards of this chapter will be used as a basis for the design and development of the binding site plan. Certain standards may be modified or deleted where appropriate to address the concept of the development while still meeting the intent of this article. HMC 340-38B; 340-36A Maximum units per lot Design and development standards of this chapter will be used as a basis for the design and development of the binding site plan. Certain standards may be modified or deleted where appropriate to address the concept of the development while still meeting the intent of this article. HMC 340-38B; 340-36A |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- All of these are true:
- The manufactured home is set on a permanent foundation
- The manufactured home's design complies with other homes in the neighborhood
- The lot is an interior or "flag" lot whose access portion reaches the public street
- None of these is true:
- The lot is an interior or "flag" lot whose access portion reaches the public street
- The project is a condominium authorized under Chapter 64.34 RCW, divided for sale or lease by binding site plan