Sign in

R-2.3 · Riverfront residential (R-2.3) zone

Granite Falls, WA · GFMC 19.03.040 · Official code

By right: 1 unit · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling, single-family
Home✓ ADU✓
————
Manufactured home
Home✓1 ADU✓1
————
Adult family home————
Home✓ ADU✓
Permanent supportive housing————
Home✓ ADU—
Transitional housing————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size100,000 sq ft GFMC 19.03.040(D)
Minimum lot width
  • 120 ft2 GFMC 19.03.040(C)
  • 100 ft3 GFMC 19.03.040(C)
Minimum lot depthEach lot should have an average depth between the front and rear lot lines of not less than one foot depth for each one foot of width. GFMC 19.04D.040(F)
Minimum densityNot set GFMC 19.03.040
  • 3 units per acre4 GFMC 19.03.040(H)
  • No limit5 GFMC 19.06.015(B)
for Dwelling, single-family (1 unit); Manufactured home (1 unit)1
Maximum densityNot set GFMC 19.03.040
  • 1 ÷ 2.3 units per acre6 GFMC 19.03.040(G)
  • 1.5 × (1 ÷ 2.3) units per acre7 GFMC 19.03.040(G); 19.06.145(C)(1)
  • No limit5 GFMC 19.06.015(B)
for Dwelling, single-family (1 unit); Manufactured home (1 unit)1
Maximum residentsNot set GFMC 19.03.040
6 persons GFMC 19.02.010
for Adult family home (group living)

3. Building standards

StandardValueExceptions
Front setback20 ft GFMC 19.03.040(B)(1)
Side setback5 ft GFMC 19.03.040(B)(2)
Street side setback20 ft GFMC 19.03.040(B)(2); 19.03.040(B)(1)
Rear setback25 ft GFMC 19.03.040(B)(3)
Maximum height33 ft GFMC 19.03.040(E)
Maximum lot coverage30% GFMC 19.03.040(F)
Maximum impervious surface30% GFMC 19.03.040(F)
Minimum parking
  • 0 spaces per unit8 GFMC 19.06.145(C)(2)
  • 2 spaces per unit9 GFMC 19.06.050(A)(9)
0.5 spaces per bed GFMC 19.06.050(A)(9)
for Adult family home (group living)
In the case of a use not specifically mentioned in subsection (A)(9) of this section, the requirements for off-street parking facilities shall be determined by the designated official. GFMC 19.06.050(A)(8)
for Permanent supportive housing (group living); Transitional housing (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units GFMC 19.06.090(C) Table 1

Building

StandardValueExceptions
Front setback20 ft GFMC 19.06.090(C) Table 1; 19.03.040(B)(1)
Side setback5 ft GFMC 19.06.090(C) Table 1; 19.03.040(B)(2)
Rear setback
  • 10 ft10 GFMC 19.06.090(C) Table 1
  • 15 ft11 GFMC 19.06.090(C) Table 1
Maximum height33 ft GFMC 19.06.090(C) Table 1; 19.03.040(E)
Minimum parking
  • 1 space per unit12 GFMC 19.06.090(C) Table 1; 19.06.050(A)(9)
  • 2 spaces per unit13 GFMC 19.06.090(C) Table 1; 19.06.050(A)(9)
Maximum unit size1,000 sq ft GFMC 19.06.090(C) Table 1
Attached to the main houseNot required GFMC 19.06.090(C)(1); 19.06.090(C)(1)(a); 19.06.090(C)(1)(b)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Subdivision, short GFMC 19.04A.210(D)Only for: Dwelling, single-family, Manufactured home, Adult family home, Permanent supportive housing, Transitional housing A up to 9 GFMC 19.05.005 1 ÷ 2.3 units per acre, a fraction of 0.5 or more rounds up, on the net lot area GFMC 19.03.040(G); 19.06.015(A)
Minimum density
3 units per acre GFMC 19.03.040(H); 19.06.015(A)
Minimum lot size
100,000 sq ft GFMC 19.03.040(D); 19.04D.040(E)
Minimum lot width
  • 120 ft2 GFMC 19.03.040(C); 19.04D.040(E)
  • 100 ft3 GFMC 19.03.040(C); 19.04D.040(E)
Minimum lot depth
Each lot should have an average depth between the front and rear lot lines of not less than one foot depth for each one foot of width. GFMC 19.04D.040(F)
Minimum frontage
Not set GFMC 19.04D.040(E)
Subdivision GFMC 19.04A.210(D)Only for: Dwelling, single-family, Manufactured home, Adult family home, Permanent supportive housing, Transitional housing H 10 or more GFMC 19.05.005 1 ÷ 2.3 units per acre, a fraction of 0.5 or more rounds up, on the net lot area GFMC 19.03.040(G); 19.06.015(A)
Minimum density
3 units per acre GFMC 19.03.040(H); 19.06.015(A)
Minimum lot size
100,000 sq ft GFMC 19.03.040(D); 19.04D.040(E)
Minimum lot width
  • 120 ft2 GFMC 19.03.040(C); 19.04D.040(E)
  • 100 ft3 GFMC 19.03.040(C); 19.04D.040(E)
Minimum lot depth
Each lot should have an average depth between the front and rear lot lines of not less than one foot depth for each one foot of width. GFMC 19.04D.040(F)
Minimum frontage
Not set GFMC 19.04D.040(E)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The manufactured home has at least two fully enclosed parallel sections, each not less than 12 feet wide by 36 feet long
  2. The lot is a corner lot (frontage on two or more streets where the streets meet)
  3. None of these is true:
    • The lot is a corner lot (frontage on two or more streets where the streets meet)
  4. The lot is being divided (short plat, subdivision, unit lot subdivision or PRD); density is calculated only for lots to be subdivided
  5. None of these is true:
    • The lot is being divided (short plat, subdivision, unit lot subdivision or PRD); density is calculated only for lots to be subdivided
  6. All of these are true:
    • The lot is being divided (short plat, subdivision, unit lot subdivision or PRD); density is calculated only for lots to be subdivided
    None of these is true:
    • The dwelling units are created entirely within an existing building, in a residential, commercial or mixed-use zone where residential uses are allowed
  7. All of these are true:
    • The lot is being divided (short plat, subdivision, unit lot subdivision or PRD); density is calculated only for lots to be subdivided
    • The dwelling units are created entirely within an existing building, in a residential, commercial or mixed-use zone where residential uses are allowed
  8. The dwelling units are created entirely within an existing building, in a residential, commercial or mixed-use zone where residential uses are allowed
  9. None of these is true:
    • The dwelling units are created entirely within an existing building, in a residential, commercial or mixed-use zone where residential uses are allowed
  10. Building stories is at most 1
  11. Building stories is more than 1
  12. Lot area is less than 6,000 sf
  13. Lot area is at least 6,000 sf