Sign in

HIGH DENSITY RESIDENTIAL · High Density Residential (HDR) District

Fife, WA · FMC 19.28 · Official code

By right: 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Courtyard apartments—
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
—
Stacked flats—
Home✓ ADU✓1 ✓2
Home✓ ADU✓1 ✓2
——
Townhouses—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Triplex dwelling——
Home✓ ADU✓
——
Multifamily structure———
Home✓ ADU✓1 ✓2
—
General group home————
Home✓ ADU—
Transitional housing————
Home✓ ADU—
Permanent supportive housing————
Home✓ ADU—
Co-living housing————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Maximum units6 units FMC 19.28.020(D)
Not set FMC 19.28.020(H)
for Multifamily structure (4+ units)3
Minimum unitsNot set FMC 19.28.020(E)
4 units FMC 19.28.020(D)
for Multifamily structure (4+ units)
7 units FMC 19.28.020(H)
for Multifamily structure (4+ units)3
Minimum lot size
  • 3,000 sq ft4 FMC 19.51.010
  • 2,500 sq ft3 FMC 19.52.030(H)
2,500 sq ft FMC 19.52.030(H)
for Multifamily structure (4+ units)3
Minimum frontage
  • 20 ft5 FMC 19.51.010
  • 14 ft6 FMC 19.51.010
Maximum density
  • 14 units per acre, a fraction of 0.5 or more rounds up4 FMC 19.51.010
  • 25 units per acre, a fraction of 0.5 or more rounds up3 FMC 19.52.030(H)
25 units per acre, a fraction of 0.5 or more rounds up FMC 19.52.030(H)
for Multifamily structure (4+ units)3
Minimum development size
  • Not set4 FMC 19.51.010
  • 130,680 sq ft3 FMC 19.52.040(A)
130,680 sq ft FMC 19.52.040(A)
for Multifamily structure (4+ units)3
Maximum sleeping unitsNot set FMC 19.28.020(I)
  • 4 × ((14 × lot area) ÷ 43,560, rounded) sleeping units4 FMC 19.51.010; 19.68.063(D)
  • 4 × ((25 × lot area) ÷ 43,560, rounded) sleeping units3 FMC 19.52.030(H); 19.68.063(D)
for Co-living housing (group living)

3. Building standards

StandardValueExceptions
Front setback
  • 16 ft4 FMC 19.51.010
  • 8 ft3 FMC 19.52.030(H)
8 ft FMC 19.52.030(H)
for Multifamily structure (4+ units)3
Side setback
  • 10 ft4 FMC 19.51.010
  • 0 ft3 FMC 19.52.030(H)
0 ft FMC 19.52.030(H)
for Multifamily structure (4+ units)3
Street side setback
  • 16 ft4 FMC 19.68.040(A)(1)(a); 19.51.010
  • 8 ft3 FMC 19.68.040(A)(1)(a); 19.52.030(H)
8 ft FMC 19.68.040(A)(1)(a); 19.52.030(H)
for Multifamily structure (4+ units)3
Rear setback
  • 10 ft4 FMC 19.51.010
  • 0 ft3 FMC 19.52.030(H)
0 ft FMC 19.52.030(H)
for Multifamily structure (4+ units)3
Building separation
  • 6 ft7 FMC 19.51.010
  • 15 ft8 FMC 19.51.010
Maximum height30 ft FMC 19.51.010
35 ft FMC 19.51.010
for Multifamily structure (4+ units); Multifamily structure (4+ units)3; Co-living housing (group living)
Maximum stories2 stories FMC 19.51.010
3 stories FMC 19.51.010
for Multifamily structure (4+ units); Multifamily structure (4+ units)3; Co-living housing (group living)
Maximum lot coverage
  • 55%4 FMC 19.51.010
  • 65%3 FMC 19.52.030(H)
65% FMC 19.52.030(H)
for Multifamily structure (4+ units)3
Minimum parking
  • 0 spaces per unit9 FMC 19.56.020(C)
  • 1 space per unit10 FMC 19.56.040(B)
  • 2 spaces per unit11 FMC 19.56.040(B)
  • 1 space per unit12 FMC 19.56.040(B)
  • 1.25 spaces per unit13 FMC 19.56.040(B)
  • 1.5 spaces per unit14 FMC 19.56.040(B)
for Multifamily structure (4+ units); Multifamily structure (4+ units)3
For uses not specifically identified in this chapter, the amount of parking required shall be based on the requirements for similar uses as determined by the director. FMC 19.56.040(J)
for General group home (group living)
The same requirement as the housing type which the unit is in plus 1 stall for each on-site employee, as applicable. FMC 19.56.040(B)
for Transitional housing (group living); Permanent supportive housing (group living)
  • 0 spaces per sleeping unit9 FMC 19.68.063(E)(1)(a)
  • 0.25 spaces per sleeping unit15 FMC 19.68.063(E)(1)(b); 19.56.040(B)
for Co-living housing (group living)
Maximum unit sizeNot set FMC 19.51.010
300 sq ft FMC 19.68.063(C)(1)(a)
for Co-living housing (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units1 unit FMC 19.80.030(A)
2 units FMC 19.80.030(A)
for Courtyard apartments (2, 3, 4+ units)1; Stacked flats (2, 3 units)1; Multifamily structure (4+ units)1; Multifamily structure (4+ units)16
Minimum lot sizeNot set FMC 19.80.030(A)
3,000 sq ft FMC 19.80.030(A); 19.51.010
for Courtyard apartments (2, 3, 4+ units)1; Stacked flats (2, 3 units)1; Multifamily structure (4+ units)1; Multifamily structure (4+ units)16

Building

StandardValueExceptions
Front setback
  • 16 ft4 FMC 19.51.010
  • 8 ft3 FMC 19.52.030(H)
Side setback
  • 10 ft4 FMC 19.51.010
  • 0 ft3 FMC 19.52.030(H)
Rear setback
  • 10 ft4 FMC 19.51.010
  • 0 ft3 FMC 19.52.030(H)
Maximum height24 ft FMC 19.80.040(A)(1)
Minimum parking
  • 0 spaces per unit17 FMC 19.56.020(D)
  • 1 space per unit18 FMC 19.56.040(B)
Maximum unit size1,000 sq ft FMC 19.80.030(C)
Attached to the main houseNot set FMC 19.80.030(A)
Required FMC 19.80.030(A)
for Courtyard apartments (2, 3, 4+ units)2; Stacked flats (2, 3 units)2; Multifamily structure (4+ units)2; Multifamily structure (4+ units)19

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision FMC 18.06.010(A)(1); 18.06.040(C)(2) A up to 9 FMC 18.03.200; 18.06.020 —
Minimum lot size
3,000 sq ft FMC 19.68.020(A)(1)(a); 19.51.010
Minimum frontage
  • 20 ft5 FMC 19.51.010
  • 14 ft6 FMC 19.51.010
Subdivision FMC 18.06.010(A)(1); 18.06.040(C)(3) H 10 or more FMC 18.03.220; 18.06.020 —
Minimum lot size
3,000 sq ft FMC 19.68.020(A)(1)(a); 19.51.010
Minimum frontage
  • 20 ft5 FMC 19.51.010
  • 14 ft6 FMC 19.51.010
Unit lot subdivision FMC 18.06.010(A)(1); 18.06.040(C)(2)Only for: Triplex dwelling, Courtyard apartments, Townhouses A20 up to 9 FMC 18.06.020 —
Minimum lot size
Not set FMC 18.06.055(B)(1)
Large lot division FMC 18.08.070(B) A 2 or more FMC 18.03.110 —
Minimum lot size
217,800 sq ft FMC 18.03.110; 18.08.070(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Lot area is at least 3,000 sf
  2. Lot area is less than 3,000 sf
  3. Project is developed as a planned residential development (PRD) under Chapter 19.52 FMC
  4. None of these is true:
    • Project is developed as a planned residential development (PRD) under Chapter 19.52 FMC
  5. None of these is true:
    • Lot has an alley or an easement serving 2 lots or less as its sole access
  6. Lot has an alley or an easement serving 2 lots or less as its sole access
  7. Building stories is at most 2
  8. Building stories is at least 3
  9. Lot is within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535
  10. All of these are true:
    • Lot area is less than 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535
  11. All of these are true:
    • Lot area is at least 6,000 sf
    None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535
  12. Bedrooms in one unit is 0
  13. Bedrooms in one unit is 1
  14. Bedrooms in one unit is at least 2
  15. None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535
  16. All of these are true:
    • Project is developed as a planned residential development (PRD) under Chapter 19.52 FMC
    • Lot area is at least 3,000 sf
  17. Lot is within one-quarter mile walking distance of a major transit stop
  18. None of these is true:
    • Lot is within one-quarter mile walking distance of a major transit stop
  19. All of these are true:
    • Project is developed as a planned residential development (PRD) under Chapter 19.52 FMC
    • Lot area is less than 3,000 sf
  20. No dwelling unit is stacked on another separate dwelling unit