Sign in

CITY CENTER NORTH · City Center North (CCN) District

Fife, WA · FMC 19.34 · Official code

By right: 2 units, 3 units, 4+ units · ADU allowed by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Multifamily structure—
Home✓ ADU✓
Home✓ ADU✓
Home✓ ADU✓
—
Mixed use structure———
Home✓ ADU✓
—
Transitional housing————
Home✓ ADU—
Permanent supportive housing————
Home✓ ADU—
Co-living housing————
Home✓ ADU—
Emergency shelter————
HomeH ADU—
Emergency housing————
HomeH ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum unitsNot set FMC 19.34.020(A)
4 units FMC 19.34.020(B)
for Mixed use structure (4+ units)
Minimum frontage20 ft FMC 19.34.050(A)

3. Building standards

StandardValueExceptions
Maximum front setbackAt least 70% of the linear frontage of a primary structure shall be set back no more than 10 feet from the front property line. FMC 19.34.050(A)
Side setback0 ft FMC 19.34.050(A)
Rear setback0 ft FMC 19.34.050(A)
Maximum height80 ft FMC 19.34.050(A)
Maximum stories6 stories FMC 19.34.050(A)
Maximum lot coverage100% FMC 19.34.050(A)
Minimum parking
  • 1 space per unit1 FMC 19.56.040(B)
  • 1.25 spaces per unit2 FMC 19.56.040(B)
  • 1.5 spaces per unit3 FMC 19.56.040(B)
The same requirement as the housing type which the unit is in plus 1 stall for each on-site employee, as applicable. FMC 19.56.040(B)
for Transitional housing (group living); Permanent supportive housing (group living)
  • 0 spaces per sleeping unit4 FMC 19.68.063(E)(1)(a)
  • 0.25 spaces per sleeping unit5 FMC 19.68.063(E)(1)(b); 19.56.040(B)
for Co-living housing (group living)
1 × employees on the largest shift spaces FMC 19.56.040(B)
for Emergency shelter (group living); Emergency housing (group living)
Maximum unit sizeNot set FMC 19.51.010
300 sq ft FMC 19.68.063(C)(1)(a)
for Co-living housing (group living)

4. ADU standards

Lot

StandardValueExceptions
Maximum units2 units FMC 19.80.030(A)

Building

StandardValueExceptions
Side setback0 ft FMC 19.34.050(A)
Rear setback0 ft FMC 19.34.050(A)
Maximum height24 ft FMC 19.80.040(A)(1)
Minimum parking
  • 0 spaces per unit6 FMC 19.56.020(D)
  • 1 space per unit7 FMC 19.56.040(B)
Maximum unit size1,000 sq ft FMC 19.80.030(C)

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision FMC 18.06.010(A)(1); 18.06.040(C)(2) A up to 9 FMC 18.03.200; 18.06.020 —
Minimum lot size
Not set FMC 19.68.020(A)(1)(a); 19.34.050
Minimum frontage
20 ft FMC 19.34.050(A)
Subdivision FMC 18.06.010(A)(1); 18.06.040(C)(3) H 10 or more FMC 18.03.220; 18.06.020 —
Minimum lot size
Not set FMC 19.68.020(A)(1)(a); 19.34.050
Minimum frontage
20 ft FMC 19.34.050(A)
Large lot division FMC 18.08.070(B) A 2 or more FMC 18.03.110 —
Minimum lot size
217,800 sq ft FMC 18.03.110; 18.08.070(A)
Binding site plan FMC 18.09.050(A) A8 2 or more FMC 18.09.010 —
Minimum lot size
Not set FMC 19.68.020(A)(1)(a); 19.34.050
Minimum frontage
20 ft FMC 19.34.050(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. Bedrooms in one unit is 0
  2. Bedrooms in one unit is 1
  3. Bedrooms in one unit is at least 2
  4. Lot is within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535
  5. None of these is true:
    • Lot is within one-half mile walking distance of a major transit stop as defined in RCW 36.70A.535
  6. Lot is within one-quarter mile walking distance of a major transit stop
  7. None of these is true:
    • Lot is within one-quarter mile walking distance of a major transit stop
  8. No future residential structure will be placed on the land, except as an accessory use