RS5.0 · Single-family residential (RS5.0)
Federal Way, WA · FWRC 19.200 · Official code
By right: 1 unit, 2 units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Detached dwelling unit | Home✓ ADU✓ | — | — | — | — |
| Permanent supportive housing and transitional housing | HomeA ADU— | HomeA ADU— | — | ||
| Middle housing | — | Home✓ ADU✓ | — | ||
| Cottage housing | — | Home✓ ADU✓ | — | ||
| Senior citizen housing | — | HomeH ADU— | HomeH ADU— | HomeH ADU— | — |
| Special needs housing | — | HomeH ADU— | HomeH ADU— | HomeH ADU— | — |
| Manufactured home parks | — | — | — | HomeH ADU— | — |
| Adult family home | — | — | — | — | Home✓ ADU✓ |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 6 units, ADUs included FWRC 19.200.020 note 2 | The city will determine the number of dwelling units or occupancy rooms or suites permitted in the proposed development FWRC 19.200.100 note 5
for Senior citizen housing (4+ units); Special needs housing (4+ units) Not set FWRC 19.200.040
for Manufactured home parks (4+ units); Permanent supportive housing and transitional housing (4+ units)1 |
| Minimum lot size | 5,000 sq ft FWRC 19.200.010 note 1(e) | 130,680 sq ft FWRC 19.200.040
for Manufactured home parks (4+ units) |
| Maximum density | Not set FWRC 19.200.010 | The city will determine the number of dwelling units or occupancy rooms or suites permitted in the proposed development FWRC 19.200.100 note 5
for Senior citizen housing (2, 3, 4+ units); Special needs housing (2, 3, 4+ units) 1 unit per 5,000 sq ft FWRC 19.200.040
for Manufactured home parks (4+ units) |
| Maximum residents | 6 persons FWRC 19.05.010 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft FWRC 19.200.010 | |
| Side setback | 5 ft FWRC 19.200.010 note 3 | 10 ft FWRC 19.200.045
for Permanent supportive housing and transitional housing (1, 2 units); Permanent supportive housing and transitional housing (3, 4+ units)1 for Senior citizen housing (2, 3, 4+ units); Special needs housing (2, 3, 4+ units) 20 ft FWRC 19.200.040
for Manufactured home parks (4+ units) |
| Street side setback | Not set FWRC 19.200.045 | 10 ft FWRC 19.200.010 note 3
for Detached dwelling unit (1 unit); Adult family home (group living) |
| Rear setback | 5 ft FWRC 19.200.010 | 20 ft FWRC 19.200.045
for Permanent supportive housing and transitional housing (1, 2 units); Permanent supportive housing and transitional housing (3, 4+ units)1; Manufactured home parks (4+ units) |
| Building separation | Not set FWRC 19.200.010 | 15 ft FWRC 19.200.040 note 2
for Manufactured home parks (4+ units) |
| Maximum height | 30 ft FWRC 19.200.010 |
for Manufactured home parks (4+ units) |
| Maximum lot coverage | 60% FWRC 19.200.010 note 6(e) | |
| Minimum parking | 2 spaces per unit FWRC 19.200.010
for Detached dwelling unit (1 unit); Manufactured home parks (4+ units) for Permanent supportive housing and transitional housing (1, 2 units); Permanent supportive housing and transitional housing (3, 4+ units)1 for Senior citizen housing (2, 3, 4+ units) for Special needs housing (2, 3, 4+ units) (2 × main dwelling units on the lot) + employees on the largest shift spaces FWRC 19.105.080(5); 19.200.010
for Adult family home (group living) | |
| Minimum open space | The subject property must provide usable open space in a total amount equal to at least 100 sq. ft. per dwelling unit. Developments of five or fewer units are exempt from this usable open space requirement. FWRC 19.200.100 note 15 | Not set FWRC 19.200.010
for Detached dwelling unit (1 unit); Middle housing (2 units); Middle housing (3, 4+ units)2; Adult family home (group living) The subject property must contain at least 150 sq. ft. of usable open space per dwelling unit. Developments of five or fewer units are exempt from this usable open space requirement. FWRC 19.200.045 note 10
for Permanent supportive housing and transitional housing (1, 2 units); Permanent supportive housing and transitional housing (3, 4+ units)1 20% FWRC 19.200.020 note 8
The subject property must contain at least 150 sq. ft. of usable open space per manufactured home. FWRC 19.200.040 note 3
for Manufactured home parks (4+ units) |
| Maximum units per building | Not set FWRC 19.200.010 | 6 units FWRC 19.200.045 note 3
for Permanent supportive housing and transitional housing (1, 2 units); Permanent supportive housing and transitional housing (3, 4+ units)1 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units FWRC 19.200.180 note 2 | |
| Minimum lot size | 5,000 sq ft FWRC 19.200.180 note 1; 19.200.010 note 1(e) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft FWRC 19.200.180; 19.200.180 note 2; 19.200.010 | |
| Side setback | ||
| Rear setback | 5 ft FWRC 19.200.180; 19.200.180 note 2; 19.200.010 | |
| Maximum height | 30 ft FWRC 19.200.180 | |
| Minimum parking | ||
| Maximum unit size | ||
| Attached to the main house | Not required FWRC 19.05.040 |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision FWRC 18.30.010(4) | A | up to 9 FWRC 18.05.010 | — | Minimum lot size 5,000 sq ft FWRC 19.200.010 note 1(e) |
| Subdivision FWRC 18.35.170 | H | 10 or more FWRC 18.05.010 | — | Minimum lot size 5,000 sq ft FWRC 19.200.010 note 1(e) |
| Unit lot subdivision FWRC 18.70.020(1)Only for: Detached dwelling unit, Middle housing, Cottage housing | A | up to 9 FWRC 18.70.020(1) | Minimum parent area 5,000 sq ft FWRC 18.55.030(1); 19.200.010 note 1(e) Minimum units 2 units FWRC 18.70.010(1) |
Maximum units per lot 1 unit FWRC 18.70.030(4) |
| Unit lot subdivision FWRC 18.70.020(1)Only for: Detached dwelling unit, Middle housing, Cottage housing | H | 10 or more FWRC 18.70.020(1) | Minimum parent area 5,000 sq ft FWRC 18.55.030(1); 19.200.010 note 1(e) Minimum units 2 units FWRC 18.70.010(1) |
Maximum units per lot 1 unit FWRC 18.70.030(4) |
| Binding site plan FWRC 18.20.050Only for: Manufactured home parks | A | — | — | Minimum lot size Not set FWRC 18.20.010 |
| Cluster subdivision FWRC 18.30.010(4) | A | Maximum lots the smallest of 9, ((lot area × 0.8) − (150 × main dwelling units on the lot)) ÷ 5,000, rounded down lots FWRC 18.05.010; 18.55.030(2); 18.55.040(2)(e)(iii) |
Minimum parent area 87,120 sq ft FWRC 18.55.040(2)(a) Area taken out for roads and utilities 20% FWRC 18.55.030(2) |
Minimum lot size the largest of 5,000 × 0.5, 5,000 sq ft FWRC 18.55.040(2)(b) |
| Cluster subdivision FWRC 18.35.170 | H | Minimum lots 10 lots FWRC 18.05.010 Maximum lots ((lot area × 0.8) − (150 × main dwelling units on the lot)) ÷ 5,000, rounded down lots FWRC 18.55.030(2); 18.55.040(2)(e)(iii) |
Minimum parent area 87,120 sq ft FWRC 18.55.040(2)(a) Area taken out for roads and utilities 20% FWRC 18.55.030(2) |
Minimum lot size the largest of 5,000 × 0.5, 5,000 sq ft FWRC 18.55.040(2)(b) |
| Lot size averaging FWRC 18.30.010(4) | A24 | Maximum lots the smallest of 9, lot area ÷ 5,000, rounded down lots FWRC 18.05.010; 19.120.110(4)(a)(iii); 19.200.010 note 1(e) |
— | Minimum lot size the largest of 5,000 × 0.5, 5,000 sq ft FWRC 19.120.110(4)(a)(ii) |
| Lot size averaging FWRC 18.35.170 | H24 | Minimum lots 10 lots FWRC 18.05.010 Maximum lots lot area ÷ 5,000, rounded down lots FWRC 19.120.110(4)(a)(iii); 19.200.010 note 1(e) |
— | Minimum lot size the largest of 5,000 × 0.5, 5,000 sq ft FWRC 19.120.110(4)(a)(ii) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Any of these is true:
- None of these is true:
- Lot is within 5,400 ft of a property with more than three units of permanent supportive housing and/or transitional housing
- Main dwelling units on the lot is at most 2
- None of these is true:
- None of these is true:
- The area is currently served only by on-site sewage systems
- The property line is adjacent to a single-family residential zone
- None of these is true:
- The property line is adjacent to a single-family residential zone
- The ground floor of the structure is parking (covenant recorded to keep it as parking)
- None of these is true:
- The ground floor of the structure is parking (covenant recorded to keep it as parking)
- A portion of a structure is less than 100 ft from a low density use or zone
- None of these is true:
- A portion of a structure is less than 100 ft from a low density use or zone
- Lot is within 1/2 mile walking distance of a major transit stop
- All of these are true:
- Lot area is less than 6,000 sf
- Lot is within 1/2 mile walking distance of a major transit stop
- All of these are true:
- Lot area is at least 6,000 sf
- Lot is within 1/2 mile walking distance of a major transit stop
- Bedrooms in one unit is less than 1
- All of these are true:
- Bedrooms in one unit is at least 1
- Bedrooms in one unit is less than 2
- Bedrooms in one unit is at least 2
- Lot is within one-quarter mile of a transit stop with service at least four times per hour for 12 or more hours per day
- None of these is true:
- Lot is within one-quarter mile of a transit stop with service at least four times per hour for 12 or more hours per day
- The side yard is on a corner lot, on the portion of the lot not adjacent to the primary vehicular access
- None of these is true:
- The side yard is on a corner lot, on the portion of the lot not adjacent to the primary vehicular access
- None of these is true:
- Lot is within 1/2 mile walking distance of a major transit stop
- The ADU is attached and its creation needs no exterior alteration of the residence (except alterations needed for it to be a functional separate residence)
- None of these is true:
- The ADU is attached and its creation needs no exterior alteration of the residence (except alterations needed for it to be a functional separate residence)
- The proposed unit lot is undeveloped at unit lot subdivision review and no building permit for it has been submitted
- None of these is true:
- The proposed unit lot is undeveloped at unit lot subdivision review and no building permit for it has been submitted
- The site contains areas with slopes in excess of 15 percent as well as areas with slopes less than 15 percent