OP-1 · Office park (OP-1)
Federal Way, WA · FWRC 19.235 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Convalescent center or nursing home | — | — | — | — | HomeA ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Minimum lot size | No limit FWRC 19.235.060 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | ||
| Side setback | 20 + (the largest of 0, building height − 35) ft FWRC 19.235.060; 19.235.060 note 1 | |
| Rear setback | 20 + (the largest of 0, building height − 35) ft FWRC 19.235.060; 19.235.060 note 1 | |
| Maximum height | ||
| Maximum lot coverage | No limit FWRC 19.235.060 note 7 | |
| Minimum parking | (beds in the project ÷ 3) + (employees on the largest shift ÷ 2) spaces FWRC 19.235.060 |
4. ADU standards
Lot
No standards.
Building
No standards.
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Binding site plan FWRC 18.20.050 | A | — | — | Minimum lot size Not set FWRC 18.20.010 |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- What the front yard holds: a visible entry and 15% glass front facade, a landscape buffer and stormwater facilities, or parking and driving areas is entry_visible_glass_facade
- What the front yard holds: a visible entry and 15% glass front facade, a landscape buffer and stormwater facilities, or parking and driving areas is landscape_stormwater_in_front
- What the front yard holds: a visible entry and 15% glass front facade, a landscape buffer and stormwater facilities, or parking and driving areas is parking_in_front
- The portion of the structure is within 100 ft of a residential zone
- All of these are true:
- The project gets the extra height approved through the specified review process (criteria in the use chart note are met)
- The portion of the structure is within 100 ft of a residential zone
- The subject property adjoins a residential zone
- All of these are true:
- Any of these is true:
- The subject property adjoins a residential zone
- None of these is true:
- The project gets the extra height approved through the specified review process (criteria in the use chart note are met)
- The portion of the structure is within 100 ft of a residential zone
- Any of these is true: