Sign in

HCB · HCB Highway and Community Business District

Enumclaw, WA · EMC 18.22 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling unit, live-work
Home✓1 H2 ADU—
Home✓1 H2 ADU—
Home✓1 H2 ADU—
Home✓1 H2 ADU—
—
Multifamily development (3+ units per structure)——
Home✓3 H4 ADU—
Home✓3 H4 ADU—
—
Adult family home protected by state and federal law————
Home✓ ADU—
Assisted care living facility, nursing home————
Home✓ ADU—
Co-living housing————
Home✓3 H4 ADU—
Group quarters, dormitories, fraternal houses, not including secure community transition facilities or halfway house————
Home✓3 H4 ADU—
Transitional housing————
HomeH5 ADU—
Permanent supportive housing————
HomeH5 ADU—
Indoor emergency shelter————
HomeH6 ADU—
Indoor emergency housing————
HomeH7 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size10,000 sq ft EMC 18.06.040(A); 18.22.040
Minimum lot widthNo limit EMC 18.06.040(A)
Maximum densityNo limit EMC 18.06.040(A)
The number of transitional housing units allowed on any given property shall be no more than the number of standard dwelling units that would be allowed under the zoning of the property; provided, that in no case shall the number of transitional housing units allowed on any given property exceed 10. EMC 18.05.020(B)(7)
for Transitional housing (group living)5
The number of permanent supportive housing units allowed on any given property shall be no more than the number of standard dwelling units that would be allowed under the zoning of the property; provided, that in no case shall the number of permanent supportive housing units allowed on any given property exceed 10. EMC 18.05.020(B)(8)
for Permanent supportive housing (group living)5
Maximum residentsNot set EMC 18.06.040(A)
40 persons EMC 18.05.020(B)(9)
for Indoor emergency shelter (group living)6; Indoor emergency housing (group living)7

3. Building standards

StandardValueExceptions
Front setback15 ft EMC 18.06.040(A)
0 ft EMC 19.38.110(A)(1)
for Dwelling unit, live-work (1, 2, 3, 4+ units)1
Maximum front setbackNot set EMC 18.06.040(A)
Where properties front one or more streets, new buildings shall not be set back from the sidewalk, with the following exceptions: a. Setbacks up to four feet may be used to highlight entrances and provide wider sidewalks. b. A setback of up to 10 feet may be allowed for the purpose of providing landscaped public space EMC 19.38.110(A)(1)
for Dwelling unit, live-work (1, 2, 3, 4+ units)1
Side setback
  • 0 ft8 EMC 18.06.040(B)(4)(a)
  • When parcels directly abut a residential-zoned property, the setback along the abutting residential property shall adhere to the residential setback standards.9 EMC 18.06.040(B)(4)(b)
Street side setback10 ft EMC 18.06.040(B)(4)(a)
Rear setback
  • 0 ft8 EMC 18.06.040(B)(4)(a)
  • When parcels directly abut a residential-zoned property, the setback along the abutting residential property shall adhere to the residential setback standards.9 EMC 18.06.040(B)(4)(b)
Maximum height
  • 35 ft10 EMC 18.06.040(A)
  • When the district abuts upon a residential district the maximum permitted building height shall not exceed the maximum building height permitted in the abutting residential district for a distance of 120 feet from the abutting boundary.11 EMC 18.06.040(B)(6)
  • 50 ft10 EMC 18.06.040(B)(7); 19.38.060(A)(1)
  • When the district abuts upon a residential district the maximum permitted building height shall not exceed the maximum building height permitted in the abutting residential district for a distance of 120 feet from the abutting boundary.11 EMC 18.06.040(B)(6)
for Dwelling unit, live-work (1, 2, 3, 4+ units)1
Maximum lot coverage40% EMC 18.06.040(A)
Minimum parking1 space per unit EMC 19.38.130(A)(1)
  • 2 spaces per unit12 EMC 19.14.070
  • 1 space per unit13 EMC 19.14.070
for Dwelling unit, live-work (1, 2, 3, 4+ units)2
(1.35 × main dwelling units on the lot) + (main dwelling units on the lot ÷ 5, rounded down), rounded up spaces EMC 19.14.080; 19.40.040(D)(4)
for Multifamily development (3+ units per structure) (3, 4+ units)4
(0.33 × beds in the project) + employees on the largest shift, rounded spaces EMC 19.14.070
for Adult family home protected by state and federal law (group living); Assisted care living facility, nursing home (group living); Group quarters, dormitories, fraternal houses, not including secure community transition facilities or halfway house (group living)4; Transitional housing (group living)5; Permanent supportive housing (group living)5; Indoor emergency shelter (group living)6; Indoor emergency housing (group living)7
  • 0 spaces per sleeping unit14 EMC 19.32.180(B)(4)
  • 0.25 spaces per sleeping unit15 EMC 19.32.180(B)(4)
for Co-living housing (group living)3; Co-living housing (group living)4
Maximum unit sizeNot set EMC 18.06.040(A)
600 sq ft EMC 19.32.180(B)(1)
for Co-living housing (group living)3; Co-living housing (group living)4
Minimum open spaceNot set EMC 18.06.040(A)
Open space shall be provided at a minimum of 10 square feet for each 100 square feet of sleeping unit space. EMC 19.32.180(B)(3)
for Co-living housing (group living)3; Co-living housing (group living)4

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short subdivision EMC 17.08.010 A up to 4 EMC 17.04.050 —
Minimum lot size
10,000 sq ft EMC 18.06.040(A); 17.08.120
Minimum lot width
No limit EMC 17.08.120; 18.06.040(A)
Subdivision EMC 17.12.010 H 5 or more EMC 17.04.050 —
Minimum lot size
10,000 sq ft EMC 18.06.040(A); 17.08.120
Minimum lot width
No limit EMC 17.16.230(A)(4); 18.06.040(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • Parcel is in the HCB mixed use overlay (between First and Third Streets and Stevenson and Mill Avenues)
    • Included within a mixed use development approved under Chapter 19.38 EMC
  2. Not all of these are true:
    • Parcel is in the HCB mixed use overlay (between First and Third Streets and Stevenson and Mill Avenues)
    • Included within a mixed use development approved under Chapter 19.38 EMC
  3. Dwellings or living quarters are located above the primary use
  4. None of these is true:
    • Dwellings or living quarters are located above the primary use
  5. None of these is true:
    • Within a quarter mile of another property that contains permanent supportive housing or transitional housing
    • Within a quarter mile of emergency housing or an emergency shelter
  6. None of these is true:
    • Within a quarter mile of a continuously operating indoor emergency housing facility
    • Within a quarter mile of another property that contains permanent supportive housing or transitional housing
  7. None of these is true:
    • Within a quarter mile of a continuously operating indoor emergency shelter
    • Within a quarter mile of another property that contains permanent supportive housing or transitional housing
  8. None of these is true:
    • Directly abuts residential-zoned property (applies along that line)
  9. Directly abuts residential-zoned property (applies along that line)
  10. None of these is true:
    • Part of the building is within 120 feet of an abutting residential district boundary
  11. Part of the building is within 120 feet of an abutting residential district boundary
  12. Bedrooms in one unit is at least 2
  13. Bedrooms in one unit is less than 2
  14. Within one-half-mile walking distance of a major transit stop
  15. None of these is true:
    • Within one-half-mile walking distance of a major transit stop