SF-2 · Single-family residential district, medium density
Eatonville, WA · EMC 18.04.020 · Official code
By right: 1 unit · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwelling | Home✓ ADU✓ | — | — | — | — |
| Permanent supportive housing | — | — | — | — | |
| Duplex | — | — | — | — | |
| Cottage housing | — | — | HomeH ADU— | HomeH ADU— | — |
| Group home, class I-A | — | — | — | — | Home✓ ADU— |
| Group home, class I-B | — | — | — | — | Home✓ ADU— |
| Retirement homes, convalescent homes, and other welfare facilities | — | — | — | — | HomeH ADU— |
| Transitional housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not read EMC 19.06 | |
| Minimum units | Not read EMC 19.06 | |
| Minimum lot size | 8,400 sq ft EMC 18.04.020(A); 18.04.020(G)(1) | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Minimum lot width | 60 ft EMC 18.04.020(G)(2) | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Minimum lot depth | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Minimum frontage | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Minimum density | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Maximum density | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Minimum development size | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Maximum residents | 7 persons EMC 18.02.173(A)(1) | 10 persons EMC 18.02.173(A)(2)
for Group home, class I-B (group living) Not set EMC 18.08.030(B)(4)
for Retirement homes, convalescent homes, and other welfare facilities (group living) Each permanent supportive housing unit or transitional housing unit is limited to the occupant maximum as specified in the Town Building and Fire Codes. EMC 18.08.360(D)
for Transitional housing (group living)1 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft EMC 18.04.020(G)(4)(a) | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Maximum front setback | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Side setback | 8 ft EMC 18.04.020(G)(4)(b) | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Total side setbacks | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Street side setback | 15 ft EMC 18.04.020(G)(4)(d) | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Rear setback | Not read EMC 19.06
for Cottage housing (3, 4+ units) | |
| Building separation | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Maximum height | 28 ft EMC 18.04.020(G)(5) | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Maximum stories | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Minimum height | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Minimum stories | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Maximum lot coverage | 40% EMC 18.04.020(G)(3) | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Maximum impervious surface | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Maximum floor area ratio | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Minimum parking | For uses not specifically identified in this section, the amount of parking required shall be determined by the planning director, based on parking required for similar uses, and, if appropriate, documentation provided by the applicant. EMC 18.05.040(H) | 2 spaces per unit EMC 18.04.020(I); 18.05.040(A)(1)(a)
Not read EMC 19.06
for Cottage housing (3, 4+ units) One parking space for each two beds, plus one parking space for each staff doctor, plus one parking space for each three employees. EMC 18.05.040(F)(2)
for Retirement homes, convalescent homes, and other welfare facilities (group living) |
| Maximum unit size | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Maximum building floor area | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Maximum lot size | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Maximum building footprint | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Minimum open space | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
| Maximum units per building | Not set EMC 18.04.020 | Not read EMC 19.06
for Cottage housing (3, 4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 1 unit EMC 18.08.045(B) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 25 ft EMC 18.08.045(C)(2); 18.04.020(G)(4)(a) | |
| Side setback | 8 ft EMC 18.08.045(C)(2); 18.04.020(G)(4)(b) | |
| Rear setback | ||
| Maximum height | 28 ft EMC 18.08.045(B)(3); 18.04.020(G)(5) | |
| Maximum unit size | the largest of 500, the smallest of 0.4 × floor area of the main house, 1,000 sq ft EMC 18.08.045(B)(4); 18.08.045(B)(4)(a) | |
| Attached to the main house | Not required EMC 18.08.045(B) | |
| Owner lives on site | Required EMC 18.08.045(E)(2) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short plat/subdivision EMC 17.44.040; 17.44.090(A) | A | up to 4 EMC 17.44.030(A) | — | Minimum lot size 8,400 sq ft EMC 18.04.020(A); 18.04.020(G)(1) Minimum lot width 60 ft EMC 18.04.020(G)(2) |
| Subdivision EMC 17.20.060; 17.20.080(A) | H | 5 or more EMC 17.20.010 | — | Minimum lot size 8,400 sq ft EMC 18.04.020(A); 18.04.020(G)(1) Minimum lot width 60 ft EMC 18.04.020(G)(2) |
| Lot size averaging EMC 17.18.050 | A | — | Minimum average lot size 8,400 sq ft EMC 17.18.050(A); 18.04.020(A) |
Minimum lot size 0.95 × 8,400 sq ft EMC 17.18.050(A)(2) |
| Zero lot line planned development EMC 18.08.300 | H | — | Minimum parent area 217,800 sq ft EMC 18.08.320(A) |
Minimum lot size 3,600 sq ft EMC 18.08.320(B) |
| Planned unit development EMC 17.17.010; 18.04.190(A); 18.04.190(E)(5) | H | — | The density of residential development for PUDs shall be based on the gross density of the underlying zoning district. The planning commission may recommend a dwelling unit density not more than 20 percent greater than that permitted by the underlying zone EMC 18.04.190(D) | Minimum lot size No limit EMC 18.04.190(C)(1) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- No other permanent supportive housing, transitional housing, emergency housing or emergency shelter is within 880 feet
- No other duplex is within 250 feet, measured from lot corner to lot corner
- None of these is true:
- The rear yard abuts an alley
- The rear yard abuts an alley