Sign in

C-2 · General commercial district

Eatonville, WA · EMC 18.04.140 · Official code

By right: 1 unit, 3 units, 4+ units · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Single-family dwelling
Home✓ ADU—
————
Duplex—
HomeH1 ADU—
———
Multifamily residential uses——
Home✓ ADU—
Home✓ ADU—
—
Permanent supportive housing———
Home✓2 ADU—
—
Group home, class I-A————
HomeH ADU—
Group home, class I-B————
HomeH ADU—
Group home, class I-C————
HomeH ADU—
Group home, class II-A————
HomeH3 ADU—
Group home, class II-B————
HomeH3 ADU—
Group home, class II-C————
HomeH3 ADU—
Class III group home————
HomeH4 ADU—
Transitional housing————
Home✓2 ADU—
Retirement homes, convalescent homes, and other welfare facilities————
HomeH ADU—
Sanitarium, convalescent and rest home services————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size10,000 sq ft EMC 18.04.140(E)(1)
Maximum residentsNot set EMC 18.02.173(C)
7 persons EMC 18.02.173(A)(1)
for Group home, class I-A (group living)
10 persons EMC 18.02.173(A)(2)
for Group home, class I-B (group living)
The number of residents for a class I-C group home will be based upon the density of the underlying zoning district. EMC 18.02.173(A)(3)
for Group home, class I-C (group living)
8 persons EMC 18.02.173(B)(1)
for Group home, class II-A (group living)3
12 persons EMC 18.02.173(B)(2)
for Group home, class II-B (group living)3
18 persons EMC 18.02.173(B)(3)
for Group home, class II-C (group living)3
20 persons EMC 18.04.140(A)(3)(c)
for Transitional housing (group living)2

3. Building standards

StandardValueExceptions
Front setback25 ft EMC 18.04.140(E)(3)
Side setback
  • 20 ft5 EMC 18.04.140(E)(4)
  • 0 ft6 EMC 18.04.140(E)(4)
Rear setback
  • 20 ft7 EMC 18.04.140(E)(5)
  • 0 ft8 EMC 18.04.140(E)(5)
Maximum height40 ft EMC 18.04.140(E)(6)
Maximum stories3 stories EMC 18.04.140(E)(6)
Maximum lot coverage40% EMC 18.04.140(E)(2)
Minimum parkingFor uses not specifically identified in this section, the amount of parking required shall be determined by the planning director, based on parking required for similar uses, and, if appropriate, documentation provided by the applicant. EMC 18.05.040(H)
2 spaces per unit EMC 18.04.140(G)(1); 18.05.040(A)(1)(a)
for Single-family dwelling (1 unit); Duplex (2 units)1
  • 1 space per unit9 EMC 18.04.140(G)(1); 18.05.040(A)(1)(c)
  • 2 spaces per unit10 EMC 18.04.140(G)(1); 18.05.040(A)(1)(c)
  • 1.8 spaces per unit11 EMC 18.04.140(G)(1); 18.05.040(A)(1)(c)
for Multifamily residential uses (3, 4+ units)
One parking space for each two beds, plus one parking space for each staff doctor, plus one parking space for each three employees. EMC 18.05.040(F)(2)
for Retirement homes, convalescent homes, and other welfare facilities (group living); Sanitarium, convalescent and rest home services (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Short plat/subdivision EMC 17.44.040; 17.44.090(A) A up to 4 EMC 17.44.030(A) —
Minimum lot size
10,000 sq ft EMC 18.04.140(E)(1)
Subdivision EMC 17.20.060; 17.20.080(A) H 5 or more EMC 17.20.010 —
Minimum lot size
10,000 sq ft EMC 18.04.140(E)(1)
Lot size averaging EMC 17.18.050 A —
Minimum average lot size
10,000 sq ft EMC 17.18.050(A); 18.04.140(E)(1)
Minimum lot size
0.95 × 10,000 sq ft EMC 17.18.050(A)(2)
Binding site plan EMC 17.14.010 A
Maximum lots
Not set EMC 17.14.010
—
Minimum lot size
10,000 sq ft EMC 18.04.140(E)(1)
Planned unit development EMC 17.17.010; 18.04.190(A); 18.04.190(E)(5) H — The density of residential development for PUDs shall be based on the gross density of the underlying zoning district. The planning commission may recommend a dwelling unit density not more than 20 percent greater than that permitted by the underlying zone EMC 18.04.190(D)
Minimum lot size
No limit EMC 18.04.190(C)(1)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. No other duplex is within 250 feet, measured from lot corner to lot corner
  2. No other permanent supportive housing, transitional housing, emergency housing or emergency shelter is within 880 feet
  3. All of these are true:
    • No other class II or III group home is within 600 feet
    • No school, church, park, playground or other sensitive use is within 1,000 feet
  4. All of these are true:
    • No other class II or III group home is within 600 feet
    • No school, church, park, playground or other sensitive use is within 1,000 feet
    • No residential area is within 1,000 feet
  5. The side yard abuts a residential district
  6. None of these is true:
    • The side yard abuts a residential district
  7. The rear yard abuts a residential district
  8. None of these is true:
    • The rear yard abuts a residential district
  9. Floor area of one unit is at most 400
  10. All of these are true:
    • Floor area of one unit is more than 400
    • Main dwelling units on the lot is at most 49
  11. All of these are true:
    • Floor area of one unit is more than 400
    • Main dwelling units on the lot is at least 50