Sign in

MUI · Mixed Use Institutional (MU-I) zoning district

Duvall, WA · DMC 14.19 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Dwelling units on upper floors
Home✓1 H2 ADU—
Home✓1 H2 ADU—
Home✓1 H2 ADU—
Home✓1 H2 ADU—
—
Co-living housing————
Home✓1 H2 ADU—
Senior citizen assisted living facility————
Home✓3 H4 ADU—
Residential care facilities————
Home✓3 H4 ADU—
Nursing and personal care facilities————
Home✓3 H4 ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size0 sq ft DMC 14.19.050(A)
Minimum lot width25 ft DMC 14.19.050(A)
Maximum densityUpper story residential only; limited by building height, parking, and other site requirements. DMC 14.19.050(A)

3. Building standards

StandardValueExceptions
Front setback0 ft DMC 14.19.050(A)
Maximum front setback20 ft DMC 14.19.050(A)
Side setback5 ft DMC 14.19.050(A)
Street side setback0 ft DMC 14.19.050(A)
Rear setback5 ft DMC 14.19.050(A)
Maximum height50 ft DMC 14.19.050(A)
Maximum storiesThree floors allowed on the uphill side and four floors allowed on the downhill side. DMC 14.19.050(A)
Maximum impervious surface85% DMC 14.19.050(A)
Minimum parking
  • 1.3 spaces per unit5 DMC 14.44.040(I)
  • 1.5 spaces per unit6 DMC 14.44.040(I)
  • 2 spaces per unit7 DMC 14.44.040(I)
0.25 × bedrooms in the whole project spaces DMC 14.44.040(I)
for Co-living housing (group living)1; Co-living housing (group living)2
(0.5 × sleeping units in the project) + employees on the largest shift spaces DMC 14.44.040(I)
for Senior citizen assisted living facility (group living)3; Senior citizen assisted living facility (group living)4
floor area of all units ÷ 300 spaces DMC 14.44.040(I)
for Residential care facilities (group living)3; Residential care facilities (group living)4
0.25 spaces per bed DMC 14.44.040(I)
for Nursing and personal care facilities (group living)3; Nursing and personal care facilities (group living)4
Maximum building floor area65,000 sq ft DMC 14.19.020
Not set DMC 14.19.040(A)
for Dwelling units on upper floors (1, 2, 3, 4+ units)2; Co-living housing (group living)2; Senior citizen assisted living facility (group living)4; Residential care facilities (group living)4; Nursing and personal care facilities (group living)4

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Binding Site Plan DMC Table 14.08.040.A; 14.66.130(B) H8 — —
Minimum lot width
25 ft DMC 14.19.050(A)
Plat—Short DMC Table 14.08.040.A; 14.66.030(A) A up to 4 DMC 14.06.160 —
Minimum lot width
25 ft DMC 14.19.050(A)
Plat—Long DMC Table 14.08.040.A; 14.66.030(A) H 5 or more DMC 14.06.160 —
Minimum lot width
25 ft DMC 14.19.050(A)
Boundary Line Adjustment DMC Table 14.08.040.A; 14.66.120 ✓ up to 0 DMC 14.06.020 —
Minimum lot width
25 ft DMC 14.19.050(A)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. All of these are true:
    • The units are on upper floors above commercial use on the ground floor
    None of these is true:
    • The project gets a conditional use permit for a building larger than the zone's building size limit
  2. All of these are true:
    • The units are on upper floors above commercial use on the ground floor
    • The project gets a conditional use permit for a building larger than the zone's building size limit
  3. None of these is true:
    • The project gets a conditional use permit for a building larger than the zone's building size limit
  4. The project gets a conditional use permit for a building larger than the zone's building size limit
  5. Bedrooms in one unit is less than 1
  6. Bedrooms in one unit is 1
  7. Bedrooms in one unit is at least 2
  8. Any of these is true:
    • The division is for lease or sale of lots or tracts for industrial or commercial purposes, with more than one principal building on one lot of record
    • The land is divided to be developed for residential condominiums, single-family attached or detached, under Chapter 64.32 RCW