Sign in

T-C · T-C Transit Community Zone

Des Moines, WA · DMMC 18.136 · Official code

By right: nothing · ADU not by right

1. What you can build

1 unit2 units3 units4+ unitsGroup living
Mixed use
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
Home✓1 ADU—
—
Adult family homes————
Home✓ ADU—
Co-living housing————
Home✓ ADU—
Permanent supportive housing————
HomeH2 ADU—
Transitional housing————
HomeH2 ADU—
Emergency housing————
HomeH2 ADU—
Emergency shelter————
HomeH2 ADU—
Retirement housing————
Home✓ ADU—
Community care facilities————
Home✓ ADU—

✓ By right   A Administrative review   H Public hearing   — Not allowed   HOME = the main building   n Only under condition n

2. Lot standards

StandardValueExceptions
Minimum lot size7,500 sq ft DMMC 18.136.060(1)
Minimum lot width75 ft DMMC 18.136.060(2)
Minimum frontage20 ft DMMC 17.35.050(4)
Maximum residentsNot set DMMC 18.136
  • 6 persons3 DMMC 18.01.050
  • 4 persons4 DMMC 18.01.050
for Adult family homes (group living)
80 persons DMMC 18.182.050(2)(a)(ii)
for Emergency shelter (group living)2
Maximum bedsNot set DMMC 18.136
floor area of all units ÷ 40, rounded down beds DMMC 18.182.050(2)(a)(ii)
for Emergency shelter (group living)2

3. Building standards

StandardValueExceptions
Front setback0 ft DMMC 18.136.060(3)
Side setback
  • 10 ft5 DMMC 18.136.060(4)
  • Not set6 DMMC 18.136.060(4)
Rear setback
  • 5 ft7 DMMC 18.136.060(11)
  • 20 ft8 DMMC 18.136.060(5)
  • 0 ft9 DMMC 18.136.060(5)
  • Not set10 DMMC 18.136.060(5)
Maximum height
  • 45 ft11 DMMC 18.136.060(9)(b)
  • 100 ft12 DMMC 18.136.060(8)
  • 75 ft13 DMMC 18.136.060(8)
Minimum height55 ft DMMC 18.136.060(7)(a)(i)
Maximum floor area ratio
  • 2.814 DMMC 18.136.070(3)(a); 18.136.070(3)(b)(i)-(ii)
  • 3.515 DMMC 18.136.070(3)(a); 18.136.070(3)(b)(i)-(ii)
  • 416 DMMC 18.136.070(3)(a); 18.136.070(3)(b)(i)-(ii)
  • 4.517 DMMC 18.136.070(3)(a); 18.136.070(3)(b)(i)-(ii)
  • 518 DMMC 18.136.070(3)(a); 18.136.070(3)(b)(i)-(ii)
  • 5.519 DMMC 18.136.070(3)(a); 18.136.070(3)(b)(i)-(ii)
  • 6.520 DMMC 18.136.070(3)(a); 18.136.070(3)(b)(i)-(ii)
Minimum parking
  • 1 + (1 ÷ 10) spaces per unit21 DMMC 18.210.090(15)(h)(iv)(A)-(B); 18.210.090(15)(h)(iv)(D)
  • 1.75 + (1 ÷ 10) spaces per unit22 DMMC 18.210.090(15)(h)(iv)(C); 18.210.090(15)(h)(iv)(D)
  • 0 spaces per unit23 DMMC 18.210.090(15)(a)(i)
  • 1 space per unit24 DMMC 18.210.090(15)(a)(ii)
for Adult family homes (group living)
  • Parking requirements of the underlying zoning district apply, if the project site is located within a mile radius of the Sea-Tac Airport25 DMMC 18.58.070(4)
  • 0 spaces per sleeping unit26 DMMC 18.58.070(2)
  • 0.25 spaces per sleeping unit27 DMMC 18.58.070(1)
for Co-living housing (group living)
(employees on the largest shift ÷ 2) + (0.5 × main dwelling units on the lot) spaces DMMC 18.210.090(15)(k)
for Permanent supportive housing (group living)2; Transitional housing (group living)2
(employees on the largest shift ÷ 2) + (beds in the project ÷ 4) spaces DMMC 18.210.090(15)(j)
for Emergency housing (group living)2; Emergency shelter (group living)2; Retirement housing (group living); Community care facilities (group living)

4. ADU standards

Lot

No standards.

Building

No standards.

5. Dividing land

DivisionApprovalLotsDensityEach new lot
Binding site plan DMMC 17.30.050(2) A up to 4 DMMC 17.30.050(2) —
Minimum lot size
7,500 sq ft DMMC 18.136.060(1)
Minimum lot width
  • 75 + 5 ft28 DMMC 18.136.060(2); 17.35.050(5)
  • 75 ft29 DMMC 18.136.060(2)
Minimum frontage
20 ft DMMC 17.35.050(4)
Binding site plan DMMC 17.30.050(2); 17.10.130 H 5 or more DMMC 17.30.050(2) —
Minimum lot size
7,500 sq ft DMMC 18.136.060(1)
Minimum lot width
  • 75 + 5 ft28 DMMC 18.136.060(2); 17.35.050(5)
  • 75 ft29 DMMC 18.136.060(2)
Minimum frontage
20 ft DMMC 17.35.050(4)
Short subdivision DMMC 17.05.140 A up to 9 DMMC 17.05.020 —
Minimum lot size
7,500 sq ft DMMC 18.136.060(1)
Minimum lot width
  • 75 + 5 ft28 DMMC 18.136.060(2); 17.35.050(5)
  • 75 ft29 DMMC 18.136.060(2)
Minimum frontage
20 ft DMMC 17.35.050(4)
Subdivision DMMC 17.10.130 H 10 or more DMMC 17.10.020 —
Minimum lot size
7,500 sq ft DMMC 18.136.060(1)
Minimum lot width
  • 75 + 5 ft28 DMMC 18.136.060(2); 17.35.050(5)
  • 75 ft29 DMMC 18.136.060(2)
Minimum frontage
20 ft DMMC 17.35.050(4)

✓ By right   A Administrative review   H Public hearing   — Not allowed

Conditions

  1. The dwelling units are in a building that also contains enclosed commercial, business, or retail uses meeting the mixed use requirements
  2. All of these are true:
    • The site is within one-quarter mile of a transit stop
    • The site is at least one-half mile from another supportive housing facility
    • Any of these is true:
      • The site is at least 1,000 feet from an elementary, middle or high school and from any other supportive housing facility
      • The facility is permitted as a family or youth shelter
  3. The Department of Social and Health Services determines the home is of adequate size and the provider can serve six adults
  4. None of these is true:
    • The Department of Social and Health Services determines the home is of adequate size and the provider can serve six adults
  5. The lot abuts Single-Family Residential zoned property
  6. None of these is true:
    • The lot abuts Single-Family Residential zoned property
  7. All of these are true:
    • The site or project area is planned for multiple buildings as one development or in phases
    • Buildings are served by a private joint-use access or street that separates the rear yards of the development sites
    • At least 30 feet of separation is provided between buildings
    • The lot abuts Single-Family Residential zoned property
  8. All of these are true:
    • Not all of these are true:
      • The site or project area is planned for multiple buildings as one development or in phases
      • Buildings are served by a private joint-use access or street that separates the rear yards of the development sites
      • At least 30 feet of separation is provided between buildings
    • The lot abuts Single-Family Residential zoned property
  9. All of these are true:
    • The lot abuts I-C zoned property
    None of these is true:
    • The lot abuts Single-Family Residential zoned property
  10. None of these is true:
    • The lot abuts Single-Family Residential zoned property
    • The lot abuts I-C zoned property
  11. The building part is within 40 feet of the abutting Single-Family Residential zone
  12. All of these are true:
    • The lot abuts I-C zoned property
    None of these is true:
    • The building part is within 40 feet of the abutting Single-Family Residential zone
  13. None of these is true:
    • The building part is within 40 feet of the abutting Single-Family Residential zone
    • The lot abuts I-C zoned property
  14. Building height is at most 35
  15. All of these are true:
    • Building height is more than 35
    • Building height is at most 50
  16. All of these are true:
    • Building height is more than 50
    • Building height is at most 60
  17. All of these are true:
    • Building height is more than 60
    • Building height is at most 70
  18. All of these are true:
    • Building height is more than 70
    • Building height is at most 80
  19. All of these are true:
    • Building height is more than 80
    • Building height is at most 90
  20. All of these are true:
    • Building height is more than 90
    • Building height is at most 100
  21. Bedrooms in one unit is at most 1
  22. Bedrooms in one unit is at least 2
  23. Floor area of one unit is at most 1,200
  24. Floor area of one unit is more than 1,200
  25. The project site is within a mile radius of the Sea-Tac Airport
  26. All of these are true:
    • The unit is within one-half mile walking distance of a major transit stop
    None of these is true:
    • The project site is within a mile radius of the Sea-Tac Airport
  27. None of these is true:
    • The project site is within a mile radius of the Sea-Tac Airport
    • The unit is within one-half mile walking distance of a major transit stop
  28. The lot is a corner lot
  29. None of these is true:
    • The lot is a corner lot