RM-2400 · RM-2,400 Residential: Multifamily 2,400 Zone
Des Moines, WA · DMMC 18.65 · Official code
By right: 1 unit, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single-family dwellings | Home✓ ADU✓ | — | — | — | — |
| Planned unit development | HomeH ADU— | HomeH ADU— | HomeH ADU— | HomeH ADU— | — |
| Mixed use | — | ||||
| Middle housing | — | — | |||
| Cottage housing | — | — | |||
| Multiple-family dwellings | — | — | Home✓ ADU— | Home✓ ADU— | — |
| Adult family homes | — | — | — | — | |
| Co-living housing | — | — | — | — | |
| Permanent supportive housing | — | — | — | — | |
| Transitional housing | — | — | — | — | |
| Group home facilities | — | — | — | — | |
| Foster care home (24 hour) | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | the largest of 4, (24 × lot area) ÷ 43,560, rounded down units, ADUs included DMMC 18.57.050; 18.57.060(1); 18.55.140(1) | Not set DMMC 18.65
the approval thereof may involve modifications in the regulations, requirements, and standards of the zone in which the project is located DMMC 18.230.120
for Planned unit development (4+ units) |
| Minimum units | Not set DMMC 18.57.050 | 3 units DMMC 18.01.050
for Multiple-family dwellings (4+ units) the approval thereof may involve modifications in the regulations, requirements, and standards of the zone in which the project is located DMMC 18.230.120
for Planned unit development (4+ units) |
| Minimum lot size | 7,200 sq ft DMMC 18.65.050 | |
| Minimum lot width | 60 ft DMMC 18.65.070 | |
| Maximum density | 1 unit per 2,400 sq ft DMMC 18.65.060 | 1 unit per the smallest of lot area ÷ 4, 43,560 ÷ 24 sq ft, ADUs included DMMC 18.57.050; 18.57.060(1)
|
| Maximum residents | Not set DMMC 18.65 | |
| Maximum sleeping units | Not set DMMC 18.65 | (4 × lot area) ÷ 2,400, rounded down sleeping units DMMC 18.65.060; 18.58.060(3)
for Co-living housing (group living)4 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft DMMC 18.65.080 | |
| Side setback | ||
| Total side setbacks | ||
| Street side setback | ||
| Rear setback | 20 ft DMMC 18.65.100; 18.65.130(1)(a) | |
| Building separation | 10 ft DMMC 18.65.130(1)(b) | |
| Maximum height | 35 ft DMMC 18.65.110 | |
| Maximum lot coverage | 50% DMMC 18.65.120 | |
| Minimum parking | 2 spaces per unit DMMC 18.210.090(15)(h)(i)
for Mixed use (1, 2, 3, 4+ units)1 for Co-living housing (group living)4 (employees on the largest shift ÷ 2) + main dwelling units on the lot spaces DMMC 18.210.090(15)(k)
| |
| Maximum unit size | Not set DMMC 18.65 | 1,600 sq ft DMMC 18.01.050
for Cottage housing (2, 3, 4+ units)2 |
| Minimum open space | Not set DMMC 18.65 | 20% DMMC 18.57.080(4)(a)
for Cottage housing (2, 3, 4+ units)2 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 3 units DMMC 18.52.010A(52); 18.55.140(1)(b); 18.57.060(2) | |
| Minimum lot size | 7,200 sq ft DMMC 18.65.050 |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 20 ft DMMC 18.65.080 | |
| Side setback | ||
| Rear setback | 20 ft DMMC 18.65.100; 18.65.130(1)(a) | |
| Maximum height | 35 ft DMMC 18.65.110 | |
| Minimum parking | 0 spaces per unit DMMC 18.210.090(15)(i); 18.210.090(15)(a)(i) | |
| Maximum unit size | 1,200 sq ft DMMC 18.52.010A(52); 18.55.140(1)(d) | |
| Attached to the main house | Not required DMMC 18.55.140(1)(b) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision DMMC 17.05.140 | A | up to 9 DMMC 17.05.020 | Minimum average lot size 7,200 sq ft DMMC 18.65.050 |
Minimum lot size 7,200 sq ft DMMC 18.65.050 Minimum frontage 20 ft DMMC 17.35.050(4) |
| Modified subdivisions and short subdivisions DMMC 17.15.060; 17.05.140 | A | up to 9 DMMC 17.05.020 | Minimum average lot size 7,200 sq ft DMMC 18.65.050 |
Minimum lot size 7,200 sq ft DMMC 18.65.050 Minimum lot width 60 ft DMMC 18.65.070; 17.15.070(2) Minimum frontage an innovative or unusual subdivision or short subdivision that does not comply with one or more of the requirements specified in chapter 17.35 DMMC DMMC 17.15.050; 17.35.050(4) |
| Subdivision DMMC 17.10.130 | H | 10 or more DMMC 17.10.020 | Minimum average lot size 7,200 sq ft DMMC 18.65.050 |
Minimum lot size 7,200 sq ft DMMC 18.65.050 Minimum frontage 20 ft DMMC 17.35.050(4) |
| Modified subdivisions and short subdivisions DMMC 17.15.060; 17.10.130 | H | 10 or more DMMC 17.10.020 | Minimum average lot size 7,200 sq ft DMMC 18.65.050 |
Minimum lot size 7,200 sq ft DMMC 18.65.050 Minimum lot width 60 ft DMMC 18.65.070; 17.15.070(2) Minimum frontage an innovative or unusual subdivision or short subdivision that does not comply with one or more of the requirements specified in chapter 17.35 DMMC DMMC 17.15.050; 17.35.050(4) |
| Binding site plan DMMC 17.30.050(2) | A23 | up to 4 DMMC 17.30.050(2) | — | Minimum lot size 7,200 sq ft DMMC 18.65.050 Minimum frontage 20 ft DMMC 17.35.050(4) |
| Binding site plan DMMC 17.30.050(2); 17.10.130 | H23 | 5 or more DMMC 17.30.050(2) | — | Minimum lot size 7,200 sq ft DMMC 18.65.050 Minimum frontage 20 ft DMMC 17.35.050(4) |
| Unit lot subdivision DMMC 17.50.050; 17.50.030Only for: Single-family dwellings, Middle housing, Cottage housing | A | 2 or more DMMC 17.01.050 | Minimum parent area 7,200 sq ft DMMC 17.50.060(1); 18.65.050 |
Minimum lot size No limit DMMC 17.50.060(4) Minimum lot width No limit DMMC 17.50.060(4) |
| Lot split DMMC 17.52.060 | A24 | up to 2 DMMC 17.52.030 | — | Minimum lot size 7,200 sq ft DMMC 18.65.050 Minimum frontage 20 ft DMMC 17.35.050(4) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- The dwelling units are in a building that also contains enclosed commercial, business, or retail uses meeting the mixed use requirements
- All of these are true:
- Lot area is at least 1,000 sf
- The lot was created through the splitting of a single residential lot or via unit lot subdivision
- The adult family home is licensed as an adult family home by the Department of Social and Health Services
- Lot area is at least 14,400 sf
- All of these are true:
- The site is within one-quarter mile of a transit stop
- The site is at least one-half mile from another supportive housing facility
- Any of these is true:
- The site is at least 1,000 feet from an elementary, middle or high school and from any other supportive housing facility
- The facility is permitted as a family or youth shelter
- The City and the proponent agree to process the application with a development agreement under chapter 18.255 DMMC
- None of these is true:
- The City and the proponent agree to process the application with a development agreement under chapter 18.255 DMMC
- The Department of Social and Health Services determines the home is of adequate size and the provider can serve six adults
- None of these is true:
- The Department of Social and Health Services determines the home is of adequate size and the provider can serve six adults
- Building stories is at most 1
- All of these are true:
- Building stories is more than 1
- Building stories is at most 2
- Building stories is more than 2
- Floor area of one unit is at most 1,200
- Floor area of one unit is more than 1,200
- The unit is within one-half mile walking distance of a major transit stop
- All of these are true:
- Floor area of one unit is at most 1,200
- The unit is within one-half mile walking distance of a major transit stop
- All of these are true:
- Floor area of one unit is more than 1,200
- The unit is within one-half mile walking distance of a major transit stop
- The project site is within a mile radius of the Sea-Tac Airport
- All of these are true:
- The unit is within one-half mile walking distance of a major transit stop
- The project site is within a mile radius of the Sea-Tac Airport
- None of these is true:
- The project site is within a mile radius of the Sea-Tac Airport
- The unit is within one-half mile walking distance of a major transit stop
- The lot is a corner lot
- None of these is true:
- The lot is a corner lot
- The improvements will be included in one or more condominiums or owned by an association
- All of these are true:
- Lot area is less than 28,800 sf
- The parent lot was created through a lot split under chapter 17.52 DMMC