R-18 · Urban Residential 18 du/ac
Covington, WA · CMC 18.15.050 · Official code
By right: 1 unit, 2 units, 3 units, 4+ units · ADU allowed by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Single detached | Home✓ ADU✓ | — | — | — | — |
| Duplex | — | Home✓ ADU✓ | — | — | — |
| Triplex | — | — | Home✓ ADU✓ | — | — |
| Townhome | — | — | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Stacked flats | — | — | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Courtyard apartments | — | — | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Cottage housing | — | — | Home✓ ADU✓ | Home✓ ADU✓ | — |
| Fourplex | — | — | — | Home✓ ADU✓ | — |
| Fiveplex | — | — | — | Home✓ ADU✓ | — |
| Sixplex | — | — | — | Home✓ ADU✓ | — |
| Multifamily | — | — | — | Home✓ ADU✓ | — |
| Manufactured home park | — | — | — | HomeH ADU✓ | — |
| Community residential facility-I | — | — | — | — | HomeH ADU— |
| Senior citizen assisted housing | — | — | — | — | Home✓ ADU— |
| Permanent supportive housing | — | — | — | — | Home✓ ADU— |
| Transitional housing | — | — | — | — | Home✓ ADU— |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set CMC 18.30.030(A) | 4 units CMC 18.20.020
for Fourplex (4+ units) 5 units CMC 18.20.020
for Fiveplex (4+ units) 6 units CMC 18.20.046
for Sixplex (4+ units) |
| Minimum units | Not set CMC 18.30.030(A) | 4 units CMC 18.20.020
for Fourplex (4+ units) 5 units CMC 18.20.020
for Fiveplex (4+ units); Multifamily (4+ units) 6 units CMC 18.20.046
for Sixplex (4+ units) 2 units CMC 18.20.034
for Manufactured home park (4+ units) |
| Minimum lot size | 2,500 sq ft CMC 18.30.030(A); CMC 18.30.120(1) | |
| Minimum lot width | 30 ft CMC 18.30.030(A) | |
| Minimum density | 18 × 0.85 units per acre CMC 18.30.030(A); CMC 18.30.030(B)(2); 18.30.030(B)(15); 18.30.060; 18.30.070(1); 18.30.090(1)-(2) | for Single detached (1 unit) 12 × 0.85 units per acre CMC 18.30.030(A); CMC 18.30.030(B)(2); 18.30.030(B)(15); 18.30.060; 18.30.070(1); 18.30.090(1)-(2); CMC 18.30.030(B)(18)
for Cottage housing (3, 4+ units) 6 × 0.85 units per acre CMC 18.30.030(A); CMC 18.30.030(B)(2); 18.30.030(B)(15); 18.30.060; 18.30.070(1); 18.30.090(1)-(2); CMC 18.30.030(B)(6)
for Manufactured home park (4+ units) Not set CMC 18.30.030(A)
for Community residential facility-I (group living); Senior citizen assisted housing (group living); Permanent supportive housing (group living); Transitional housing (group living) |
| Maximum density | No limit CMC 18.25.030(1)(a); 18.30.030(B)(21)
for Single detached (1 unit); Duplex (2 units) for Cottage housing (3, 4+ units) for Manufactured home park (4+ units) Not set CMC 18.30.030(A); CMC 18.30.030(B)(12)
for Community residential facility-I (group living) | |
| Minimum development size | Not set CMC 18.30.030(A) | 130,680 sq ft CMC 18.35.130(1)
for Manufactured home park (4+ units) |
| Maximum residents | Not set CMC 18.30.030(A) | 10 − employees on the largest shift persons CMC 18.20.014
for Community residential facility-I (group living) |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft CMC 18.30.030(A) | |
| Side setback | 10 ft CMC 18.30.030(A) | |
| Street side setback | 10 ft CMC 18.30.030(A) | |
| Rear setback | 10 ft CMC 18.30.030(A) | |
| Building separation | Not set CMC 18.30.030(A) | 10 ft CMC 18.35.130(7)
for Manufactured home park (4+ units) |
| Maximum height | 45 ft CMC 18.30.030(A); CMC 18.30.030(B)(22) | 35 ft CMC 18.30.030(A)
for Single detached (1 unit); Multifamily (4+ units); Manufactured home park (4+ units); Community residential facility-I (group living); Senior citizen assisted housing (group living); Permanent supportive housing (group living); Transitional housing (group living) |
| Maximum stories | Not set CMC 18.30.030(A) | 3 stories CMC 18.20.046
for Stacked flats (3, 4+ units) |
| Maximum impervious surface | 75% CMC 18.30.030(A) | No limit CMC 18.35.130(4)
for Manufactured home park (4+ units) |
| Minimum parking | 2 spaces per unit CMC 18.50.030(1)
for Single detached (1 unit); Manufactured home park (4+ units) for Multifamily (4+ units) 0.5 × bedrooms in the whole project spaces CMC 18.50.030(1)
for Community residential facility-I (group living) 0.5 spaces per unit CMC 18.50.030(1); CMC 18.50.050(1)
for Senior citizen assisted housing (group living) Not set CMC 18.50.030(1)
for Permanent supportive housing (group living); Transitional housing (group living) | |
| Minimum open space | Not set CMC 18.30.030(A) | 20% CMC 18.35.320(1)(a)
for Cottage housing (3, 4+ units) |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units CMC 18.35.335(2); 18.25.030(1)(a)(i) | |
| Minimum lot size | No limit CMC 18.35.335(1) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 10 ft CMC 18.30.030(A); 18.35.335(5)(c) | |
| Side setback | 10 ft CMC 18.30.030(A); 18.35.335(5)(c) | |
| Rear setback | 10 ft CMC 18.30.030(A); 18.35.335(5)(c) | |
| Maximum height | 24 ft CMC 18.35.335(5)(b) | |
| Minimum parking | ||
| Maximum unit size | ||
| Attached to the main house | Not required CMC 18.25.030(1)(a)(i); 18.35.335(2) | |
| Owner lives on site | Not required CMC 18.35.335(3)(a) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision CMC 17.20.010; 17.20.060(1); 18.25.030(1)(b)(i) | A | up to 9 CMC 17.20.050(1); 17.20.050(3) |
Minimum density 18 × 0.85 units per acre CMC 18.30.030(A); CMC 18.25.030(1)(b)(ii); 18.30.090(1)-(2) |
Minimum lot size 2,500 sq ft CMC 18.30.030(A) Minimum lot width 30 ft CMC 18.30.030(A) |
| Subdivision CMC 17.20.010; 17.20.030(1); 18.25.030(1)(b)(i) | H | 10 or more CMC 17.10.320 |
Minimum density 18 × 0.85 units per acre CMC 18.30.030(A); CMC 18.25.030(1)(b)(ii); 18.30.090(1)-(2) |
Minimum lot size 2,500 sq ft CMC 18.30.030(A) Minimum lot width 30 ft CMC 18.30.030(A) |
| Clustered development CMC 18.35.040; 18.35.040(1) | A | — | Minimum lot size 2,500 sq ft CMC 18.30.030(A) | |
| Zero-lot-line development CMC 18.35.030(1); 18.35.030(3)Only for: Cottage housing, Courtyard apartments, Duplex, Fiveplex, Fourplex, Sixplex, Stacked flats, Townhome, Triplex | A | — | Minimum lot size These standards may be modified under the provisions for zero-lot-line developments in Chapter 18.35 CMC. CMC 18.30.030(B)(3); 18.35.030(2)(a) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- None of these is true:
- Townhouse development uses a zero-lot-line subdivision
- Townhouse development uses a zero-lot-line subdivision
- None of these is true:
- Applicant pre-plans the site by showing the single residence is located compatible with future division meeting minimum density
- The dwelling is located within 15 feet of one or more of the site's interior lot lines
- Any of these is true:
- Applicant pre-plans the site by showing the single residence is located compatible with future division meeting minimum density
- The dwelling is located within 15 feet of one or more of the site's interior lot lines
- None of these is true:
- Project uses residential density incentives (Chapter 18.90 CMC) or transfer of density credits (Chapter 18.95 CMC)
- Project uses residential density incentives (Chapter 18.90 CMC) or transfer of density credits (Chapter 18.95 CMC)
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is at most 6,000 sf
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is more than 6,000 sf
- Lot is within one-half mile walking distance of a major transit stop
- Bedrooms in one unit is at most 0
- All of these are true:
- Bedrooms in one unit is more than 0
- Bedrooms in one unit is at most 1
- All of these are true:
- Bedrooms in one unit is more than 1
- Bedrooms in one unit is at most 2
- Bedrooms in one unit is more than 2
- ADUs on the lot is at most 1
- All of these are true:
- ADUs on the lot is at least 2
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- ADUs on the lot is at least 2
- Lot is within one-half mile walking distance of a major transit stop
- None of these is true:
- ADU is wholly contained within a basement or attic
- ADU is wholly contained within a basement or attic