NC · Neighborhood Commercial
Covington, WA · CMC 18.15.060 · Official code
By right: nothing · ADU not by right
1. What you can build
| 1 unit | 2 units | 3 units | 4+ units | Group living | |
|---|---|---|---|---|---|
| Duplex | — | — | — | — | |
| Triplex | — | — | — | — | |
| Townhome | — | — | — | ||
| Stacked flats | — | — | — | ||
| Courtyard apartments | — | — | — | ||
| Cottage housing | — | — | — | ||
| Fourplex | — | — | — | — | |
| Fiveplex | — | — | — | — | |
| Sixplex | — | — | — | — | |
| Multifamily | — | — | — | — | |
| Live-work | — | — | — | — | |
| Community residential facility-I | — | — | — | — | |
| Community residential facility-II | — | — | — | — | HomeH ADU— |
| Permanent supportive housing | — | — | — | — | |
| Transitional housing | — | — | — | — |
✓ By right A Administrative review H Public hearing — Not allowed HOME = the main building n Only under condition n
2. Lot standards
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | Not set CMC 18.30.040(A) | 4 units CMC 18.20.020
for Fourplex (4+ units)1 5 units CMC 18.20.020
for Fiveplex (4+ units)1 6 units CMC 18.20.046
for Sixplex (4+ units)1 |
| Minimum units | Not set CMC 18.30.040(A) | 4 units CMC 18.20.020
for Fourplex (4+ units)1 6 units CMC 18.20.046
for Sixplex (4+ units)1 |
| Maximum density | Not set CMC 18.30.040(A)
for Community residential facility-I (group living)1; Community residential facility-II (group living) | |
| Maximum residents | Not set CMC 18.30.040(A) | 10 − employees on the largest shift persons CMC 18.20.014
for Community residential facility-I (group living)1 |
3. Building standards
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft CMC 18.30.040(A) | |
| Side setback | ||
| Street side setback | 0 ft CMC 18.30.040(A) | |
| Rear setback | ||
| Maximum height | 35 ft CMC 18.30.040(A) | |
| Maximum stories | Not set CMC 18.30.040(A) | 3 stories CMC 18.20.046
for Stacked flats (3, 4+ units)1 |
| Maximum lot coverage | (10,000 ÷ 43,560) × 100% CMC 18.30.040(B)(12) | |
| Maximum impervious surface | 85% CMC 18.30.040(A) | |
| Minimum parking | for Multifamily (4+ units)1 for Live-work (4+ units)1 0.5 × bedrooms in the whole project spaces CMC 18.50.030(1)
for Community residential facility-I (group living)1; Community residential facility-II (group living) | |
| Maximum building footprint | 5,000 sq ft CMC 18.30.040(A); CMC 18.30.040(B)(11) | |
| Minimum open space | 10% CMC 18.35.100(4)(c) | 20% CMC 18.35.320(1)(a)
for Cottage housing (3, 4+ units)1 |
4. ADU standards
Lot
| Standard | Value | Exceptions |
|---|---|---|
| Maximum units | 2 units CMC 18.35.335(2); 18.25.030(1)(a)(i) | |
| Minimum lot size | No limit CMC 18.35.335(1) |
Building
| Standard | Value | Exceptions |
|---|---|---|
| Front setback | 0 ft CMC 18.30.040(A); 18.35.335(5)(c) | |
| Side setback | ||
| Rear setback | ||
| Maximum height | 24 ft CMC 18.35.335(5)(b) | |
| Minimum parking | ||
| Maximum unit size | ||
| Attached to the main house | Not required CMC 18.25.030(1)(a)(i); 18.35.335(2) | |
| Owner lives on site | Not required CMC 18.35.335(3)(a) |
5. Dividing land
| Division | Approval | Lots | Density | Each new lot |
|---|---|---|---|---|
| Short subdivision CMC 17.20.010; 17.20.060(1) | A | up to 9 CMC 17.20.050(1); 17.20.050(3) | — | Minimum lot size Not set CMC 18.30.040(A) Minimum lot width Not set CMC 18.30.040(A) |
| Subdivision CMC 17.20.010; 17.20.030(1) | H | 10 or more CMC 17.10.320 | — | Minimum lot size Not set CMC 18.30.040(A) Minimum lot width Not set CMC 18.30.040(A) |
| Binding site plan CMC 17.30.020(1) | A | Minimum lots Not set CMC 17.30.030 |
— | Minimum lot size Not set CMC 18.30.040(A) |
✓ By right A Administrative review H Public hearing — Not allowed
Conditions
- Housing is part of a mixed-use development
- None of these is true:
- Project uses residential density incentives (Chapter 18.90 CMC) or transfer of density credits (Chapter 18.95 CMC)
- Project uses residential density incentives (Chapter 18.90 CMC) or transfer of density credits (Chapter 18.95 CMC)
- Property line adjoins a residential zone
- None of these is true:
- Property line adjoins a residential zone
- All of these are true:
- Property line adjoins a residential zone
- Not all of these are true:
- A standalone townhouse development is proposed
- Adjacent property has an existing townhouse development
- Any of these is true:
- None of these is true:
- Property line adjoins a residential zone
- All of these are true:
- A standalone townhouse development is proposed
- Adjacent property has an existing townhouse development
- None of these is true:
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is at most 6,000 sf
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- Lot area is more than 6,000 sf
- Lot is within one-half mile walking distance of a major transit stop
- Bedrooms in one unit is at most 0
- All of these are true:
- Bedrooms in one unit is more than 0
- Bedrooms in one unit is at most 1
- All of these are true:
- Bedrooms in one unit is more than 1
- Bedrooms in one unit is at most 2
- Bedrooms in one unit is more than 2
- ADUs on the lot is at most 1
- All of these are true:
- ADUs on the lot is at least 2
- Lot is within one-half mile walking distance of a major transit stop
- All of these are true:
- ADUs on the lot is at least 2
- Lot is within one-half mile walking distance of a major transit stop
- None of these is true:
- ADU is wholly contained within a basement or attic
- ADU is wholly contained within a basement or attic